APC 2400 VA, 990-2233A, SURTA3000XL user manual Connectors Type Description

Page 5

 

 

Installation

Connectors

Type

Description

 

120V/3000 VA

Connect equipment to the Power

 

PDU Receptacles

Distribution Unit (PDU)

 

 

receptacles on the rear of the UPS.

OUTPUT:

120V 50-60 Hz

20A

 

 

 

UNINTERRUPTABLE

 

 

 

LR63938

POWER S UPPLY

 

 

 

LIS TE D 42C2

 

 

 

 

E95 463

 

 

 

 

Model: SURTA3000XL

 

 

 

 

3000VA / 2100W

 

 

OUTPUT: 120V 50-60 Hz

15A PER RECEPTACLE GROUP

 

 

 

 

 

100V/2400 VA

Connect equipment to the Power

 

 

50-60Hz

PDU Receptacles

Distribution Unit (PDU)

 

 

100V~

 

 

 

 

20A

 

receptacles on the rear of the UPS.

 

 

 

 

 

 

 

100V~50-60Hz 24A MAX

 

 

 

 

(NEMA L5-30P)

 

 

 

2400

24A 2.4KVA / 1680W

 

100V~

 

 

 

 

50-60Hz

 

 

 

 

20A

 

 

 

 

 

 

100V~

 

 

 

 

50-60Hz

 

 

 

 

15A

 

 

LIS TE D 42C2

Uninterruptible

 

 

 

E95 463

Power Supply

 

 

 

 

 

 

110-120 V

Connect equipment to the Power

 

 

 

3000 VA

Distribution Unit (PDU)

 

 

 

PDU Receptacles

receptacles on the rear of the UPS.

:

110-120V

50-60Hz 20A

 

: 110-120V~50-60Hz 24A MAX

 

 

 

 

 

(NEMA L5-30P)

 

 

LR63938

Model:

 

 

 

 

 

 

 

LIS TE D 42C2

SURTA3000XLTW

 

 

 

E95 463

3000VA / 2100W

:110-120V 50-60 Hz

15A PER RECEPTACLE GROUP

 

 

1.Connect ground cable of voltage surge-suppression equipment or the optional Smart-UPS RT battery pack to the TVSS screw.

2.Add optional accessories to the Smart-Slot.

a.Remove the cover and screws. Discard or save cover. Do not attempt to reinstall it.

b.Refer to the accessory manual to install equipment.

Smart-UPS RT 2400/3000 VA Tower/Rack-Mount UPS User Manual

5

Image 5
Contents APC Smart-UPS Page Contact Information Safety Information Introduction/Before InstallationUnpacking and Equipment Placement About this ManualTo Install the UPS in a Rack InstallationTo Install the UPS in a Tower Configuration To Install the UPS with External Battery PacksConnectors Type Description Connect Power and Start Up the UPS If Required, Connect the Emergency Power Off EPO FeatureConnect the Battery and Install the Front Bezel For Additional Computer System Security Terminal Mode ConfigurationDisplay Panel Display Panel IndicatorsOperation Utility Voltage Measurement On Battery OperationDisplay Panel Functions UPS ID Upsiden Configuration SettingsFunction Factory User Selectable Description Default Choices Storage Storage, Maintenance, Transport, and ServiceTo Install a Replacement Battery Storage, Maintenance, Transport, and Service Transporting the UPS to Another Location Service TroubleshootingUPS is not providing expected backup time There is no utility power Regulatory Approvals Radio Frequency WarningCopyright Notice Limited Warranty