5Switched On Status Indicator
If illuminated, power is on at all outlets except those with a pro- grammed delay.
6Delayed On Status Indicator
If illuminated, power is ‘on’ at those outlets.
7Line Trim Status Indicator
Automatic Voltage Regulation (AVR) is engaged to correct high input voltage conditions.
8SEQ/AVR Push Button
This push button is used to adjust the AVR range of the H10, as well as to set the Delay time for sequenced outlets. To adjust
H10 AVR range, or to set the Delay time, proceed as follows:
To set the AVR range:
1.Push and hold the SEQ/AVR push button for three seconds; all LEDs are extinguished, indicating the H10 is in delay programming mode. The LED corresponding to the current AVR range setting flashes (Narrow, Normal, or Wide).
2.To change AVR range, press the SEQ/AVR push button until the LED corresponding to the desired setting flashes. After releasing the push button, the unit returns to normal status and the normally illuminated LEDs are lit.
The AVR Range adjustments have the following value:
•Narrow AVR Range: 102-132 Volts,
Regulates to: 120 Volts + 5%
•Normal AVR Range: 97-139 Volts,
Regulates to: 120 Volts + 10%
•Wide AVR Range:
Regulates to: 120 Volts + 15%
- 5 -