APC H10 manual Technical Specifications

Page 21

Technical Specifications

The following table contains the specifications for the H10.

Item

Specification

 

 

INPUT

 

 

 

Input Voltage Range for Opera-

92V - 145V

tion (on utility)

 

 

 

Nominal Voltage

120 Vac

 

 

Allowable Input Frequency for

47 - 63 Hz

Operation (on utility)

 

 

 

Rated Input Current

12 Amps

 

 

Input Circuit Breaker Rating

15 Amps

 

 

OUTPUT

 

 

 

Number of Outlets

12 (all outlets are surge pro-

 

tected, conditioned, and regu-

 

lated)

 

 

Outlet type

NEMA 5-15R

 

 

Rated VA Capacity

1000VA

 

 

Rated Watt Capacity (continuous)

1000 Watts

 

 

Rated Output Current

12 Amps

 

 

SURGE PROTECTION

 

 

 

Let-Through Voltage Rating

<40 Volts

 

 

Peak Surge Current (NM + CM)

230KA

 

 

Data Line Protection Jacks (split-

Single-line 2-wire phoneline

ter)

protection for phone, modem, or

 

fax.

 

 

Coax

 

 

 

MISCELLANEOUS

 

 

 

DC Trigger

Two 3.5mm mini-jack plugs

 

(5-30V)

 

 

EMI/RFI

40-100dB at 100KHz-30MHz

 

 

Total Surge Joules

4720

 

 

- 13 -

Image 21
Contents Model H10 Type Power Conditioner Page Safety Information Safety Information Safety Symbols Page Front and Rear Panels Page Proven Expertise…Proven Reliability IntroductionPackage Contents Safety PrecautionsUnit Power Capacity FeaturesIsolated Noise Filter Banks Infb Surge ProtectionDC Trigger Removable Support FeetLine OK Status Indicator Front Panel Controls and IndicatorsFiltering Status Indicator Line Boost Status IndicatorDelayed On Status Indicator Switched On Status IndicatorLine Trim Status Indicator SEQ/AVR Push Button10 On/Off switch To set the Delay time for the sequenced outletsOverload Status Indicator LED Display and Unit CustomizationH10 Rear Panel Connectors Rear Panel Connectors and Circuit BreakerAC-Powered Outlets Input Power Connector Surge Protected COAX/RF ConnectorsSystem Ground Terminal Circuit BreakerAdditional Surge Protected COAX/RF Connectors DC Trigger jacksSurge Protected Telephone Jacks Installation Apply PowerMake Connections Set Up the H10 Specification Technical SpecificationsFederal Communications Commission FCC Compliance Information Unit will not turn on TroubleshootingWiring OK Indicator LED is not illuminated Technical Support