American Power Conversion 3000, 5000 manual Hot swappable modules, Emergency Power Off EPO, Display

Page 6

1.0 Introduction

1.2 Hot swappable modules

The IU is capable of autonomous operation and allows service or upgrade of the Electronics Unit without interruption of power to the load. In addition, a worn Battery Pack can be replaced, or new packs can be added, while maintaining power to the load. In the event of EU failure, functions controlled by the EU are automatically bypassed and the IU operates autonomously. For servicing, this bypass mode may be selected manually.

1.3 Emergency Power Off (EPO)

For applications where, for safety reasons, power to all room equipment may be cut off, the UPS provides a remote Emergency Power Off interface.

1.4 Display

Local UPS user interface is served by a display and control panel containing a back-lit 2×16 character display and three buttons. Using the buttons, menus for displaying UPS status, UPS control commands, UPS setup, UPS tests and UPS diagnostics are shown. Critical UPS functions can be password protected. A loud audible alarm warns of operating modes that could result in the loss of power to the load without user intervention.

1.5 Remote interfaces

The UPS provides a full RS-232 communications computer interface. When used with PowerDoctor UPS monitoring software and a serially connected local DOS PC, the local display and control panel functions are duplicated and power quality events can be logged. PowerChute plus offers the features of PowerDoctor, and the control of orderly and unattended network or multi-user computer system shutdown. Also available for the UPS is the SNMP (Simple Network Management Protocol) Adapter to provide load-type independent remote monitoring and management over Ethernet or Token Ring based LANs or WANs capable of routing IP messages. Using any standard Network Management System (NMS) and the SNMP Adapter, the UPS is manageable through a single familiar interface—from across your building or across the world.

3

Image 6
Contents Matrix UPS Important safety instructions Radio frequency interferenceLimited Warranty Life Support PolicyTable of Contents Introduction OverviewDisplay Emergency Power Off EPOHot swappable modules Remote interfacesSafety EnglishSécurité FrançaisSicherheit Vorsicht¡Seguridad ¡ATENCIONIsolation Unit IU Input circuit breaker power on / OFFPresentation Isolation Unit IUEU separating screw Wiring inspection coverPower distribution plate Cx IEC 320 C13 receptaclesElectronics Unit EU Electronics Unit EUCooling fans Battery communications jack Battery Pack couplerAccessory panel Manual bypass switchInput battery communications jack Battery PackBattery Pack Output battery communications jackReplace Battery indicator Battery Pack panel couplerBattery Pack cables In-line Battery Pack couplerProtection Strategies InstallationReceiving inspection Moving the UPSPlacement Input voltage requirements 1 208 Vac operation2 220-240 Vac operation Installation procedures Required materialsInput hard wiring procedure Required toolsInstallation Typical input cable installation Input voltage tap selection-208 Vac, 50/60 Hz use only Output wiring procedure ¡- -y Zxyé Module interconnections Installation ÇxzÑ Emergency Power Off EPO interfaceÉx z¸ é ´´ éx z¸ Xéé f Sgf j z¸Lgj Start-upOperation Modes of operationBypass mode Transfer between modes of operationDefault screens Display and controls operationMain menu screens UPS Control menu UPS Status menuUPS Diagnostics menu Operation UPS Setup Operation Operation Password protection UPS TestsPowerChute Software UPS MonitoringInterface Kits Computer Interface port Difficulty Difficulté Schwierigkeit VorsichtDificultad ¡ATENCIONPage Fault messages UPS requires serviceReplace Electronics Unit EU Replacing the Electronics Unit Replacing or adding Battery Packs UnitObtaining Service Storing the UPS Storage conditionsExtended storage Output Characteristics SpecificationsTransfer Characteristics InputEnvironment PhysicalApprovals Page Recharge Time, Load Recharge Computer Declaration of Conformity Toll free technical support Return shipment addresses Serial Numbers

3000, 5000 specifications

American Power Conversion (APC) has long been a leader in the manufacturing of uninterruptible power supplies (UPS), and among its range of products, the APC 5000 and 3000 series stand out for their robust performance and reliability. These UPS systems are designed to ensure a continuous flow of power, protecting sensitive electronic equipment from fluctuations and outages.

The APC 5000 and 3000 models boast a range of key features that make them suitable for both commercial and residential applications. One of the primary characteristics is their high power capacity. The 5000 model provides a substantial 5000VA/4500W output, while the 3000 variant offers 3000VA/2700W. This enables users to connect multiple devices and critical loads without the risk of overload.

Both models utilize advanced double conversion technology, which ensures that the output power is consistently clean and stable. This technology is crucial for sensitive electronics, as it filters out voltage irregularities, providing pure sine wave output. This characteristic is particularly important for equipment like servers, data centers, and networking hardware, as it enhances their longevity and operational efficiency.

Another notable feature is their extended battery runtime capability. The APC 5000 and 3000 units are designed with hot-swappable batteries, allowing for easy replacement without interrupting the power supply. This enhances the overall reliability of the system, ensuring that even during maintenance, equipment remains operational.

In terms of connectivity, both models come equipped with multiple outlets for various plug types, as well as USB and network ports for monitoring and management. The integration with APC's PowerChute software allows users to manage power preferences, monitor battery health, and receive alerts when attention is needed. This level of monitoring is essential for facilities management teams, allowing them to ensure continuous operations without power-related disruptions.

The APC 5000 and 3000 also feature robust thermal management systems. With built-in fans, these units ensure efficient airflow and heat dissipation, protecting internal components from damage due to overheating.

In conclusion, the APC 5000 and 3000 series represent a powerful solution for those seeking reliable power protection. With their advanced technologies, multiple connectivity options, and serviceability features, these UPS systems stand out as trusted components in any power management strategy. Whether in a data center or a home office, the reliability and efficiency of these models make them invaluable in today’s power-dependent environment.