Selecting Installation Position

It is necessary to select a proper environment to install the unit, in order to minimize the possibility of damage to the UPS and extend the life of the UPS (FIG. 8).

• Keep at least 20cm (8") clearance from the rear panel of the UPS from the wall or other obstructions.

• Do not block the air-flow to the ventilation openings of the unit.

• Please ensure that the installation site environmental conditions are in accordance with the UPS working specifications to avoid overheat and excessive moisture.

• Do not place the UPS in a dusty or corrosive environment or near any flammable objects.

• This UPS is not designed for outdoor use.

FIG. 8 Selecting Installation Position

UPS Setup

The UPS offers a flexible form factor enabling integration into a wide variety of environments (FIG. 9). The UPS with space-saving design only occupies 2 RU.

FIG. 9 UPS Setup

If you are installing the UPS in a tower, continue to the following section, "Tower Setup", otherwise; continue to "Rack-Mount Setup".

12

NXA-UPS1500 Uninterruptible Power Supply

Image 16
Contents NXA-UPS1500 AMX Limited Warranty and Disclaimer Table of Contents Battery Replacement Features NXA-UPS1500 Uninterruptible Power SupplyOverview Product Specifications NXA-UPS1500 Product SpecificationsFront Panel LCD Other AMX EquipmentNXA-UPS1500 Uninterruptible Power Supply Important Notice Storage InstructionsImportant Safety Instructions Assembling the Battery Pack Accessing the Battery Compartment Step One Accessing the Battery Compartment Step TwoAccessing the Battery Compartment Step Three Page Accessories for Tower and Rack Mount Mounting the NXA-UPS1500Place the UPS Properly UnpackingSelecting Installation Position UPS SetupTower Setup Step One Tower SetupTower Setup Step Two Rack-Mount Setup Step One Rack-Mount SetupRack-Mount Setup Step Two Rack-Mount Setup Step Three Rack-Mount Setup Step FourRack-Mount Setup Step Five Connecting the UPS Connect Utility and LoadConnect Network Surge Protection Connect the RS-232 Communication PortRS-232 Communication Port Pin Assignment NetLinxUPSConnecting the UPS NXA-UPS1500 Uninterruptible Power Supply Operation Operation Assembling the Battery Pack Battery ReplacementReplacing the UPS Battery Step One Replacing the UPS Battery Step Three Replacing the UPS Battery Step TwoRecycling the Used Battery NXA-UPS1500 EPM Installation Important Safety InstructionsEPM Specifications Important NoticeSelecting Installation Position EPM Installation and OperationUnpacking Tower Installation Step One EPM Installation InstructionsTower Installation Step Two Use With UPS Step One Using the EPM With The UPSUse With UPS Step Two Rack Mount Installation Step One EPM Rack Mount InstallationRack Mount Installation Step Two Rack Mount Installation Step Three Rack Mount Installation Step FourConnecting the EPM To the UPS EPM Storage InstructionsReplacing the Battery in the EPM Step One Replacing the Battery In the EPMReplacing the Battery in the EPM Step Two Replacing the Battery in the EPM Step Three Replacing the Battery in the EPM Step FourUPS Maintenance NXA-UPS1500 Uninterruptible Power Supply It’s Your World Take Control