Oki PAGE 6E Reactivity Data Stability Stable, Spill Cleanup and Disposal, Safe Handling and Use

Page 52

Overexposure to amorphous silica has been associated with causing irritation of the lungs and pneumoconio- sis. Long-term inhalation exposure may be associated with producing tumors in laboratory animals.

Reactivity Data

Stability: Stable

Polymerization: Will not occur.

Hazardous Decomposition Products: Thermal decom- position may result in release of oxides of carbon and nitrogen.

Temperature: Do not expose to temperatures above 200° C (392° F).

Incompatibility: Avoid exposure to strong oxidizers.

Spill Cleanup and Disposal

Spill Cleanup

Small Spills

1.Remove sources of ignition.

44

2.Clean up spill with wet cloth. Large Spills

1.Remove sources of ignition.

2.Wear protective gear: respirator, rubber gloves, goggles (see below)

3.Clean up spill with scoop, being careful not to generate a lot of dust.

Waste Disposal: Follow appropriate federal, state and local regulations.

Safe Handling and Use

Respiratory Protection: Not normally required. For large spills, use NIOSH-approved full face-piece respirator with HEPA cartridge during cleanup.

Protective Gloves and/or Eye Protection: Not normally required. For large spills, use rubber gloves and chemical worker’s goggles during cleanup.

Ventilation: Outside of normal ventilation, not normally required.

Service and Support

Image 52
Contents Users Guide Users Guide Safety Instructions Okipage 6eUsers Guide Okipage 6e Users Guide Table of Contents Problem Solving Optional Accessories ConsumablesCheck Contents Okidata OnlinePrinter Components LatchesSetting Up Your Printer Remove the protective sheetInstalling Toner Push the blue lever forward Using Recycled Print Media Choosing PaperInstalling Paper Top Paper Exit Paper Exit PathsRear Paper Exit Manual Feed Transparencies/Adhesive LabelsPrinting Envelopes Choosing EnvelopesConnecting Your Printer Click Have Disk Installing Printer SoftwareOkidata Okipage 6e Hi-Per W appears click Next Installing the Okipage 6e Software for Windows Installing the Okipage 6e Software for Windows NT Installing the DOS Operator Panel Using the Status Monitor Setting Features in the Online Operator Panel Printer Maintenance Replacing theToner CartridgeTab Toner Cartridge Life Replacing the Image Drum Cartridge Resetting the Drum Counter Image Drum Cartridge LifeRunning a Cleaning Cleaning the LED Array Expanding Memory Problem Solving Clearing Paper JamsProblem Solving Print Quality Problems Problem Solving Software Problems Hardware Problems Service and Support This information is valid for the United States and CanadaFaxable Facts Okidata Regional Service CenterEast Purchasing Supplies Okidata Service Centers contd CentralCanada Limited Warranty Overnight Exchange Okidata Service Centers Index Users Guide Okipage 6e For more information, contact Okidata at EmergencyHazardous Ingredients Physical DataFire and Explosion Hazard Data Health Hazard DataCarbon black PolypropyleneReactivity Data Stability Stable Spill Cleanup and DisposalSafe Handling and Use June