Specifications

Model Name

 

 

PCX5000

 

Model Number

DAZ8850F

 

Compliant Standard

DOCSIS 1.0 (1.1Based)

Interface

 

Computer Interface

10/100Base-T (10/100Mbps, full/half-duplex, auto-sensing)

 

 

 

 

4 port; USB Device (12Mbps, full speed mode) 1 port

 

 

 

Wireless Interface

IEEE 802.11b

 

 

 

 

Cable Interface

F type female 75ohm

Receiver

 

Demodulation

64/256QAM

 

 

 

 

Physical Speed

30Mbps (64QAM) /43Mbps (256QAM)

 

 

 

Frequency Range

88MHz to 860MHz (edge to edge)

 

 

 

Bandwidth

6MHz

 

 

 

 

Input Signal Level

-15dBmV to +15dBmV

 

 

 

 

(Automatically Gain Controlled by CM)

Transmitter

 

Modulation

QPSK / 16QAM

 

 

 

Physical Speed

320, 640, 1280, 2560, 5120kpbs (QPSK)

 

 

 

 

640, 1280, 2560, 5120, 10240kps (16QAM)

 

 

 

Frequency Range

5 to 42MHz (edge to edge)

 

 

 

Bandwidth

0.2, 0.4, 0.8, 1.6, 3.2MHz

 

 

 

Output Signal Level

+8dBmV to +58dBmV (QPSK)

 

 

 

 

+8dBmV to +55dBmV (16QAM)

 

 

 

 

(Output signal level of CM is automatically controlled by CMTS

 

 

 

 

through power ranging function)

 

 

 

 

Step: 1dB

 

Max. Number of CPEs

NAT-ON: 252

 

 

 

 

 

NAT-OFF: 31 (31 MAC address)

Filtering

 

MAC Address

1 to 31 (set by MIB)

 

 

LLC

16

 

 

 

IP

32

 

DHCP

 

Subnet / Mask

192.168.100.xx

/ 255.255.255.0 (factory default)

Server

 

Lease Address Range

192.168.100.2

to 192.168.100.127 (factory default)

 

 

Reserved Addresses

192.168.100.128 to 192.168.100.253 (factory default)

Gateway Address

192.168.100.254 (factory default)

HTTP Web

 

LAN-Side Address

192.168.100.1

 

Server

 

 

 

 

 

Frequency

 

Frequency Cache

4 entries

 

Search

 

Channel Plan

Supports 3 North American Channel Plan (STD, IRC, HRC)

Safety

 

 

 

UL1950, UL1310 (AC-DC adapter)

EMC

 

 

FCC Part 15 class B

Power

 

AC-DC Adapter

100-120V±10%, 50/60Hz

Supply

 

 

(Note: AC Adapter itself is 100-240V, but AC cord is 120V)

 

 

 

Internal Power Supply

DC 5V 2.4A (change connector)

 

 

 

Consumption

10 Watts (approximately)

OSS

 

Protocol

SNMP/ICMP

 

 

 

 

MIB

MIB II / MCNS MIB / Toshiba MIB

Environment

 

Operating temperature

32°F (0°C) to 104°F (40°C)

 

 

 

Operating humidity

10% to 90%(Non condensing)

 

 

 

Storage temperature

-4°F (-20°C) to 140°F (60°C)

Orientation

 

 

Horizontal and wall mounting

Reset switch

 

 

Reset to factory default

LED

 

 

POWER, CABLE, TEST, USB, WLAN, 10/100Mbps[1-4],

 

 

 

 

LINK/ACT[1-4]

 

Dimensions (without A C-DC Adapter)

8.5” x 8”.8 x 1.7” (WxDxH) unit: inch

Weight

 

 

2.1lbs. (approximately)

8

Image 48
Contents PCX5000 Page Table of Contents Features IntroductionSystem Requirements Contact InformationInstallation Important Rules for Safe OperationUse and Maintenance ServiceWhat is DOCSIS? OverviewHow does the PCX5000 work? How does the PCX5000 connect to a computer?Getting Started Contacting your Cable ProviderPCX5000 Front and Rear View Front View figureRear View figure CD-ROM Contents Important InformationSetting Up Your PCX5000 and Computers Installing the PCX5000PCX5000 to Computer Connection figure Wireless is not active PCX5000 Front Panel figureOff 100Mbps1-4Mounting the PCX5000 on a Wall Configuring Your Computers Installing the Ethernet ConnectionsInstalling the USB Drivers Installing the USB DriversWindows 2000 USB Driver Installation Example PreparationConfiguring the Computer for Wireless Operation Mode InfrastructureClick the + next to Universal Serial Bus Controllers Windows Network Configuration Network Configuration for Windows 98SE and Windows MeNetwork Configuration for Windows Network Configuration for Windows XP Macintosh Ethernet and Wireless Network Configuration Macintosh OS 9 Configuration Ethernet SettingsMacintosh OS 9 AirPort Settings Macintosh OS X Configuration Ethernet Settings Configuring PCX5000 Gateway Macintosh OS X AirPort SettingsYou may also check the PCX5000 status PCX5000 Administration Pages Login for the first timePCX5000 Welcome Main Menu Side Bar DetailImportant Information Important information Page Page Page Page New screen appears PCX5000 Wireless Configuration Important InformationImportant Information Signal-to-noise ratio of the downstream signal in dB SofaWare Advanced Security Features Reports PagesPage Page UDP and 256 TCP traffic out. All inbound traffic is blocked Page Page Frequently Asked Questions Can I dial into my home network using the PCX5000? Can I dial into my company’s VPN using the PCX5000?How do I use the PCX5000 with an existing router? Does the PCX5000 support IPX or AppleTalk?How do I upgrade my PCX5000? How will I be notified of new firmware upgrades? What is router mode?What is bridge mode? LED Diagnostics Function Color DefinitionSpecifications Qpsk / 16QAMRegulatory FCC NoticeGlossary MAC Address Modem registrationNetwork driver RJ-45Standard Limited Warranty End-User License Agreement