Siemens CP 343-1 manual Contents

Page 3

Contents

Contents

Contents − Part A

Ethernet CPs − General information

see general part

Note

Please remember that Part A of the device manual also belongs to the description of the CP. Among other things, it contains explanations of the safety notices and general information that applies to all S7 CPs for Industrial Ethernet.

You will find the references in this Part B of the manual /.../ in the Appendix of the general Part A of the manual.

The following version of the manual Part A of the manual belongs to this version of Part B: Release 01/2007

You can download the general Part from the Internet:

http://www4.ad.siemens.de/view/cs/en/8777865

Contents − Part B3L

1

Properties / Services

B3L−5

2

Requirements for Use

B3L−8

3

Installation and Commissioning

B3L−11

 

3.1

Procedure / Steps

B3L−11

4

Displays . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

B3L−14

5

Performance Data

B3L−17

 

5.1

Number of Possible Connections over Ethernet

B3L−17

 

5.2

Characteristic Data for S7 Communication

B3L−17

 

5.3

Characteristics of the SEND/RECEIVE Interface

B3L−18

 

5.4

Characteristic Data for PROFINET IO

B3L−19

6

Configuring and Programming the CP as a PROFINET IO Device

B3L−20

 

6.1

Overview of the Preparatory Steps

B3L−20

 

6.2

Principle of Data Exchange over PROFINET IO

B3L−21

 

6.3

Configuration

B3L−22

 

6.3.1

Installing the CP and Specifying it as PROFINET IO Device

B3L−22

 

6.3.2

Assigning the PROFINET IO Device to a PROFINET IO Controller . .

B3L−24

 

6.4

Programming

B3L−27

 

6.4.1

Interface for Programming on the PROFINET IO Device

B3L−27

CP 343-1 Lean for Industrial Ethernet / Manual Part B3L

B3L−3

Release 03/2007

 

C79000-G8976-C198-04

Image 3
Contents CP 343-1 Lean S7-CPs for Industrial EthernetCompatibility with the Previous Version Address label Unique MAC address preset for the CPProduct Names Printed Product Information Supplied with the ProductContents B3L−53 B3L−33B3L−44 B3L−46B3L−5 Properties / ServicesServices ApplicationProperties / Services B3L−7 ConfigurationProgramming − Using Blocks Version / NCM IE Functions of the CPOrder Number Requirements for UseGeneral Operation B3L−8CPU 314 IFM B3L−9B3L−10 Step Explanation / Meaning Installation and Commissioning Procedure / StepsGround/Chassis Ground Concept B3L−13 Not relevant for Profinet IO data DC 5 V power supply via the backplane bus green = OKDisplays Acyclic data exchange, for example Send/ReceiveGreen LEDs for displaying the modeCP Operating Mode SFred BF redP1 / P2 LEDs for displaying the CP communication statusB3L−16 Display Meaning RX/TX greenNumber of Possible Connections over Ethernet Characteristic Data for S7 CommunicationCharacteristic Explanation / Values Performance DataCharacteristics of the SEND/RECEIVE Interface Execution Times of the FCs Agsend / AgrecvComponent Explanation / Values Characteristic Data for Profinet IO CP as Profinet IO deviceExecution times of the FCs Pniosend / Pniorecv Intelligent Profinet IO Device Configuring and Programming the CP as a Profinet IO DeviceConfigurationProgramming Overview of the Preparatory StepsPrinciple of Data Exchange over Profinet IO Installing the CP and Specifying it as Profinet IO Device ConfigurationB3L−23 Download the configuration data to the Simatic 300 stationRequirements for Configuration in Step Configuring the Profinet IO controllerProfinet IO Controller B3L−25 ResultProperties Dialog of the Device Assigning the Device Name Configuring the properties of the CP as Profinet IO deviceProgramming Interface for Programming on the Profinet IO DeviceFCs Initialization and Configuration Data consistencyInitialization Reasons for reinitialization WatchdogB3L−29 Pniorecv Pniosend Example of Configuration and ProgrammingB3L−31 Call interface Pniosend in the user programB3L−32 Call interface Pniorecv in the user programWeb diagnostics opens with the Start Web DiagnosticsSettings for Access to Diagnostic Data Starting and Working with Web DiagnosticsLayout of the Diagnostics Pages Diagnostics Pages of the CPStatus StartParameter Function GeneralVersion IdentificationParameter IdentificationRack Configuration Rack name Rack ConfigurationB3L−38 Diagnostic Buffer EventsDetails no. of the event IP parameters Industrial EthernetParameters Tab Network attachmentStatistics Tab TCP Connections TabUDP Connections Tab Parameters of a Profinet IO Device Profinet IO ConfigurationAssigned Pnio controller B3L−43Extended Functionality Replacing Older Modules / Replacing Faulty ModulesUse as a Replacement Compatibility with Predecessor ProductsModule Replacement Originally configured module Configuration StepsB3L−45 Further Notes on Operation Memory ResetHow to Use the Function DefaultsAutocrossing Working with Fast Ethernet − automatic switchoverBehavior after Memory Reset How Automatic Switchover of the Network Settings WorksFurther Notes Automatic Setting or Individual Network SettingsSupported MIB Objects Snmp AgentInfluence of MPI on Connections via Industrial Ethernet Access Permissions using Community NameSpecial Features of IP Configuration Protocol Port number ServiceReserved Port Numbers Gsdml file Other information available about the CPRequirements How to Load New FirmwareHow to Download New Firmware LEDs to Indicate the CP ModeB3L−54 Technical SpecificationsB3L−55 B3L−56
Related manuals
Manual 22 pages 56.26 Kb