Siemens CP 343-1 manual B3L−33, B3L−44, B3L−46, B3L−53, B3L−54

Page 4

Contents

 

6.4.2

Initialization and Configuration

B3L−28

 

6.5

Example of Configuration and Programming

B3L−30

7

Web Diagnostics

B3L−33

 

7.1

Requirements and Use

B3L−33

 

7.2

Diagnostics Pages of the CP

B3L−34

 

7.2.1

Start Page

B3L−35

 

7.2.2

Identification

B3L−36

 

7.2.3

Rack Configuration

B3L−37

 

7.2.4

Diagnostic Buffer

B3L−39

 

7.2.5

Industrial Ethernet

B3L−40

 

7.2.6

PROFINET IO

B3L−42

8

Compatibility with Predecessor Products

B3L−44

 

8.1

Extended Functionality

B3L−44

 

8.2

Replacing Older Modules / Replacing Faulty Modules

B3L−44

9

Further Notes on Operation

B3L−46

 

9.1

Memory Reset

B3L−46

 

9.2

Working with Fast Ethernet − automatic switchover

B3L−47

 

9.3

SNMP Agent

B3L−49

9.4Possible Security Gaps on Standard IT Interfaces / Preventing

 

Illegal Access

B3L−50

9.5

Influence of MPI on Connections via Industrial Ethernet

B3L−50

9.6

Special Features of IP Configuration

B3L−51

9.7

Reserved Port Numbers

B3L−51

9.8

Restart after Detection of a Duplicate IP Address in the Network . . . .

B3L−52

9.9

Obtaining the IP Address over DHCP − CP STOP on Expiry of

 

 

the Lease

B3L−52

9.10

Other information available about the CP

B3L−52

10 How to Load New Firmware

B3L−53

11 Technical Specifications

B3L−54

B3L−4

CP 343-1 Lean for Industrial Ethernet / Manual Part B3L

Release 03/2007

C79000-G8976-C198-04

Image 4
Contents S7-CPs for Industrial Ethernet CP 343-1 LeanAddress label Unique MAC address preset for the CP Product NamesPrinted Product Information Supplied with the Product Compatibility with the Previous VersionContents B3L−33 B3L−44B3L−46 B3L−53Properties / Services ServicesApplication B3L−5Properties / Services Configuration Programming − Using BlocksVersion / NCM IE Functions of the CP B3L−7Requirements for Use General OperationB3L−8 Order NumberB3L−9 CPU 314 IFMB3L−10 Installation and Commissioning Procedure / Steps Step Explanation / MeaningGround/Chassis Ground Concept B3L−13 DC 5 V power supply via the backplane bus green = OK DisplaysAcyclic data exchange, for example Send/Receive Not relevant for Profinet IO dataLEDs for displaying the mode CP Operating ModeSFred BF red GreenLEDs for displaying the CP communication status B3L−16Display Meaning RX/TX green P1 / P2Characteristic Data for S7 Communication Characteristic Explanation / ValuesPerformance Data Number of Possible Connections over EthernetExecution Times of the FCs Agsend / Agrecv Characteristics of the SEND/RECEIVE InterfaceComponent Explanation / Values CP as Profinet IO device Characteristic Data for Profinet IOExecution times of the FCs Pniosend / Pniorecv Configuring and Programming the CP as a Profinet IO Device ConfigurationProgrammingOverview of the Preparatory Steps Intelligent Profinet IO DevicePrinciple of Data Exchange over Profinet IO Configuration Installing the CP and Specifying it as Profinet IO DeviceDownload the configuration data to the Simatic 300 station B3L−23Configuring the Profinet IO controller Requirements for Configuration in StepProfinet IO Controller Result B3L−25Configuring the properties of the CP as Profinet IO device Properties Dialog of the Device Assigning the Device NameInterface for Programming on the Profinet IO Device ProgrammingFCs Data consistency Initialization and ConfigurationInitialization Watchdog Reasons for reinitializationB3L−29 Example of Configuration and Programming Pniorecv PniosendCall interface Pniosend in the user program B3L−31Call interface Pniorecv in the user program B3L−32Web Diagnostics Settings for Access to Diagnostic DataStarting and Working with Web Diagnostics Web diagnostics opens with the StartDiagnostics Pages of the CP Layout of the Diagnostics PagesStart Parameter FunctionGeneral StatusIdentification ParameterIdentification VersionRack Configuration Rack Configuration Rack nameB3L−38 Events Diagnostic BufferDetails no. of the event Industrial Ethernet Parameters TabNetwork attachment IP parametersTCP Connections Tab Statistics TabUDP Connections Tab Profinet IO Configuration Parameters of a Profinet IO DeviceB3L−43 Assigned Pnio controllerReplacing Older Modules / Replacing Faulty Modules Use as a ReplacementCompatibility with Predecessor Products Extended FunctionalityOriginally configured module Configuration Steps Module ReplacementB3L−45 Memory Reset How to Use the FunctionDefaults Further Notes on OperationWorking with Fast Ethernet − automatic switchover Behavior after Memory ResetHow Automatic Switchover of the Network Settings Works AutocrossingAutomatic Setting or Individual Network Settings Further NotesSnmp Agent Supported MIB ObjectsAccess Permissions using Community Name Influence of MPI on Connections via Industrial EthernetProtocol Port number Service Special Features of IP ConfigurationReserved Port Numbers Other information available about the CP Gsdml fileHow to Load New Firmware How to Download New FirmwareLEDs to Indicate the CP Mode RequirementsTechnical Specifications B3L−54B3L−55 B3L−56
Related manuals
Manual 22 pages 56.26 Kb