Siemens CP 343-1 manual Statistics Tab, TCP Connections Tab, UDP Connections Tab

Page 41

7 Web Diagnostics

“Statistics” Tab

This page displays information on sent and received frames since the last module restart.

Parameter

Function

Data packets sent

Number of error-free frames sent, number of unicast, multicast and broadcast frames and the frames canceled due to a collision

Received data packets

Number of error-free received frames, received unicast, multicast and broadcast frames, frames rejected due to checksum or alignment errors and frames rejected due to a lack of resources

“TCP Connections” Tab

This page informs you about existing TCP connections.

Parameter

Function

 

 

Number

Consecutive number of the TCP connection

 

 

Local IP address

IP address of the CP

 

 

Partner IP address

Partner IP address

 

 

Local port

Number of the port used for the TCP connection

 

 

Partner port

Number of the port on the partner used for the TCP connection

 

 

Status

Connection status of the TCP connection, for example:

 

S LISTEN (waiting for connection)

 

S ESTABLISHED (existing connection)

 

S TIME WAIT (wait state prior to connection termination) and

 

S other interim statuses such as SYN SENT, SYN RECV, CLOSING etc.)

 

 

“UDP Connections” Tab

This page informs you about existing UDP connections.

Parameter

Function

 

 

Number

Consecutive number of the UDP connection

 

 

Local IP address

IP address of the CP

 

 

Partner IP address

Partner IP address

 

 

local port

Number of the port used for the UDP connection

 

 

Partner port

Number of the port on the partner used for the UDP connection

 

 

CP 343-1 Lean for Industrial Ethernet / Manual Part B3L

B3L−41

Release 03/2007

C79000-G8976-C198-04

Image 41
Contents CP 343-1 Lean S7-CPs for Industrial EthernetProduct Names Address label Unique MAC address preset for the CPPrinted Product Information Supplied with the Product Compatibility with the Previous VersionContents B3L−44 B3L−33B3L−46 B3L−53Services Properties / ServicesApplication B3L−5Properties / Services Programming − Using Blocks ConfigurationVersion / NCM IE Functions of the CP B3L−7General Operation Requirements for UseB3L−8 Order NumberCPU 314 IFM B3L−9B3L−10 Step Explanation / Meaning Installation and Commissioning Procedure / StepsGround/Chassis Ground Concept B3L−13 Displays DC 5 V power supply via the backplane bus green = OKAcyclic data exchange, for example Send/Receive Not relevant for Profinet IO dataCP Operating Mode LEDs for displaying the modeSFred BF red GreenB3L−16 LEDs for displaying the CP communication statusDisplay Meaning RX/TX green P1 / P2Characteristic Explanation / Values Characteristic Data for S7 CommunicationPerformance Data Number of Possible Connections over EthernetComponent Explanation / Values Characteristics of the SEND/RECEIVE InterfaceExecution Times of the FCs Agsend / Agrecv Execution times of the FCs Pniosend / Pniorecv Characteristic Data for Profinet IOCP as Profinet IO device ConfigurationProgramming Configuring and Programming the CP as a Profinet IO DeviceOverview of the Preparatory Steps Intelligent Profinet IO DevicePrinciple of Data Exchange over Profinet IO Installing the CP and Specifying it as Profinet IO Device ConfigurationB3L−23 Download the configuration data to the Simatic 300 stationProfinet IO Controller Requirements for Configuration in StepConfiguring the Profinet IO controller B3L−25 ResultProperties Dialog of the Device Assigning the Device Name Configuring the properties of the CP as Profinet IO deviceFCs ProgrammingInterface for Programming on the Profinet IO Device Initialization Initialization and ConfigurationData consistency B3L−29 Reasons for reinitializationWatchdog Pniorecv Pniosend Example of Configuration and ProgrammingB3L−31 Call interface Pniosend in the user programB3L−32 Call interface Pniorecv in the user programSettings for Access to Diagnostic Data Web DiagnosticsStarting and Working with Web Diagnostics Web diagnostics opens with the StartLayout of the Diagnostics Pages Diagnostics Pages of the CPParameter Function StartGeneral StatusParameter IdentificationIdentification VersionRack Configuration Rack name Rack ConfigurationB3L−38 Details no. of the event Diagnostic BufferEvents Parameters Tab Industrial EthernetNetwork attachment IP parametersUDP Connections Tab Statistics TabTCP Connections Tab Parameters of a Profinet IO Device Profinet IO ConfigurationAssigned Pnio controller B3L−43Use as a Replacement Replacing Older Modules / Replacing Faulty ModulesCompatibility with Predecessor Products Extended FunctionalityB3L−45 Module ReplacementOriginally configured module Configuration Steps How to Use the Function Memory ResetDefaults Further Notes on OperationBehavior after Memory Reset Working with Fast Ethernet − automatic switchoverHow Automatic Switchover of the Network Settings Works AutocrossingFurther Notes Automatic Setting or Individual Network SettingsSupported MIB Objects Snmp AgentInfluence of MPI on Connections via Industrial Ethernet Access Permissions using Community NameReserved Port Numbers Special Features of IP ConfigurationProtocol Port number Service Gsdml file Other information available about the CPHow to Download New Firmware How to Load New FirmwareLEDs to Indicate the CP Mode RequirementsB3L−54 Technical SpecificationsB3L−55 B3L−56