Siemens CP 343-1 manual B3L−43, Assigned Pnio controller

Page 43

7 Web Diagnostics

Parameter

Function

 

 

Status

Status of the device:

 

S OK

 

(problem-free operation)

 

S No connection to PROFINET IO controller

 

(connection disrupted or broken down)

 

S PROFINET IO blocks are not called correctly

 

(the blocks are not called or not correctly called)

 

 

Assigned PNIO controller

 

 

Device name

Device name of the assigned controller

 

 

IP address

IP address of the controller

 

 

CP 343-1 Lean for Industrial Ethernet / Manual Part B3L

B3L−43

Release 03/2007

C79000-G8976-C198-04

Image 43
Contents CP 343-1 Lean S7-CPs for Industrial EthernetCompatibility with the Previous Version Address label Unique MAC address preset for the CPProduct Names Printed Product Information Supplied with the ProductContents B3L−53 B3L−33B3L−44 B3L−46B3L−5 Properties / ServicesServices ApplicationProperties / Services B3L−7 ConfigurationProgramming − Using Blocks Version / NCM IE Functions of the CPOrder Number Requirements for UseGeneral Operation B3L−8CPU 314 IFM B3L−9B3L−10 Step Explanation / Meaning Installation and Commissioning Procedure / StepsGround/Chassis Ground Concept B3L−13 Not relevant for Profinet IO data DC 5 V power supply via the backplane bus green = OKDisplays Acyclic data exchange, for example Send/ReceiveGreen LEDs for displaying the modeCP Operating Mode SFred BF redP1 / P2 LEDs for displaying the CP communication statusB3L−16 Display Meaning RX/TX greenNumber of Possible Connections over Ethernet Characteristic Data for S7 CommunicationCharacteristic Explanation / Values Performance DataExecution Times of the FCs Agsend / Agrecv Characteristics of the SEND/RECEIVE InterfaceComponent Explanation / Values CP as Profinet IO device Characteristic Data for Profinet IOExecution times of the FCs Pniosend / Pniorecv Intelligent Profinet IO Device Configuring and Programming the CP as a Profinet IO DeviceConfigurationProgramming Overview of the Preparatory StepsPrinciple of Data Exchange over Profinet IO Installing the CP and Specifying it as Profinet IO Device ConfigurationB3L−23 Download the configuration data to the Simatic 300 stationConfiguring the Profinet IO controller Requirements for Configuration in StepProfinet IO Controller B3L−25 ResultProperties Dialog of the Device Assigning the Device Name Configuring the properties of the CP as Profinet IO deviceInterface for Programming on the Profinet IO Device ProgrammingFCs Data consistency Initialization and ConfigurationInitialization Watchdog Reasons for reinitializationB3L−29 Pniorecv Pniosend Example of Configuration and ProgrammingB3L−31 Call interface Pniosend in the user programB3L−32 Call interface Pniorecv in the user programWeb diagnostics opens with the Start Web DiagnosticsSettings for Access to Diagnostic Data Starting and Working with Web DiagnosticsLayout of the Diagnostics Pages Diagnostics Pages of the CPStatus StartParameter Function GeneralVersion IdentificationParameter IdentificationRack Configuration Rack name Rack ConfigurationB3L−38 Events Diagnostic BufferDetails no. of the event IP parameters Industrial EthernetParameters Tab Network attachmentTCP Connections Tab Statistics TabUDP Connections Tab Parameters of a Profinet IO Device Profinet IO ConfigurationAssigned Pnio controller B3L−43Extended Functionality Replacing Older Modules / Replacing Faulty ModulesUse as a Replacement Compatibility with Predecessor ProductsOriginally configured module Configuration Steps Module ReplacementB3L−45 Further Notes on Operation Memory ResetHow to Use the Function DefaultsAutocrossing Working with Fast Ethernet − automatic switchoverBehavior after Memory Reset How Automatic Switchover of the Network Settings WorksFurther Notes Automatic Setting or Individual Network SettingsSupported MIB Objects Snmp AgentInfluence of MPI on Connections via Industrial Ethernet Access Permissions using Community NameProtocol Port number Service Special Features of IP ConfigurationReserved Port Numbers Gsdml file Other information available about the CPRequirements How to Load New FirmwareHow to Download New Firmware LEDs to Indicate the CP ModeB3L−54 Technical SpecificationsB3L−55 B3L−56
Related manuals
Manual 22 pages 56.26 Kb