Siemens S7-300 manual Welcome, In addition, you will need the following components, Order number

Page 10
You can also use the

1 Welcome

Note

You can also use the

CPU 312C with an extra-low voltage that is safely isolated from the supply system. Safe isolation can be achieved, for example, in accordance with VDE 0100 Part 410 / HD 384- 4-41 / IEC 364-4-41 or

VDE 0805 / EN 60950 / IEC 950 or VDE 0106 Part 101.

6

• In addition, you will need the following components:

 

 

Order number

Quantity

Item

(Siemens)

 

 

 

1

Power supply

6ES7307-1EA00-0AA0

 

 

 

1

PC with USB interface

-

 

 

 

1

STEP 7 Lite V3.0 + Service Pack 2

Can be downloaded free

 

 

of charge on the Internet

 

 

 

various

M6 screws and nuts (length depends on installa-

Commercially available

 

tion location) with suitable screwdriver/wrench

 

1

Screwdrivers with 3.5 mm and 4.5 mm blade

Commercially available

 

widths

 

 

 

 

1

Diagonal cutters and wire stripping tool

Commercially available

 

 

 

1

Crimp tool

Commercially available

 

 

 

X m

Cable with 10 mm2 cross-section for grounding

Commercially available

 

the mounting rail and suitable cable lug for M6

 

 

screw. Length of cable depends on local condi-

 

 

tions

 

 

 

 

Approxi-

Flexible cable with 1 mm2 cross-section and

Commercially available

mately 2 m

suitable ferrules with insulated collar, length

 

 

6 mm

 

X m

3-wire flexible network cable (230/120 VAC) with

Commercially available

 

grounding-type socket plug; length dependent

 

 

on local conditions and suitable ferrules with

 

 

insulating collar

 

4

Single-pole momentary contact switch

Commercially available

 

(24 V, 2 A)

 

 

 

 

1

Motor, including accessories (optional)

Commercially available

 

You can find technical specifications for the

 

CPU 312C in the “CPU 31xC and CPU 31x: Technical Specifications” Manual available on the Internet at http://www.siemens.com/automa- tion/service&support.

SIMATIC S7-300 Getting Started for First Time Users Getting Started, 04/2007, 6ZB5310-0NC02-0BA0

Image 10
Contents SIMATIC S7-300 Getting Started for First Time Users 04/2007Order No. 6ZB5310-0NC02-0BA0 Danger Safety GuidelinesQualified Personnel Trademarks Prescribed UsageDisclaimer of Liability Page Contents 7 Congratulations1 Welcome To accomplish this, you will perform the following tasks Prerequisites 1 WelcomeValidity You will need a microQuantity Materials and toolsOrder number SiemensYou can also use the In addition, you will need the following componentsVDE 0805 / EN 60950 / IEC 950 or VDE 0106 Part Page 2 Preparing the PC Installing the driver for the PC Adapter USB Installing STEP 7 LiteOpen the installation file and follow the instructions 1. Open the dialog for setting the PG/PC interface Setting the interface2 Preparing the PC Page 2 Preparing the PC Page 3 Installing and wiring the hardware 3.1 What components are required? Installing and grounding the mounting rail 3.2 Installing the components3 Installing and wiring the hardware 2. Connect the mounting rail to the ground wire2. Install the CPU 312C Installing modules on the mounting rail1. Install the power supply, tighten ing the screws hand-tight1. Cut the cables to the desired 3.3 Wiring the componentsPreparing the cables 2. Remove the insulation and press2. Connect the power cable to the power supply Wiring the CPU 312C and the power supply1. Prepare the power cable 3. Secure the power cableWiring the momentary contact switches 1. Connect the momentary contact switches to the digital inputsWiring the motor 1. Connect the power supply for the digital inputs2. Wire the motor, if available. This step is optional Connecting the front panel connector Checking the line voltage setting 2. If necessary, change the switch position for the line voltage3.4 Commissioning the hardware Connecting the CPU 312C and the PC1. Connect the USB cable to the PC Adapter and your PC 2. Close the front panel Supplying power to the CPU 312C 1. Connect the supply cable to the supply system3 Installing and wiring the hardware 3. Set the main switch of the power supply to “ON” Testing the connections Page 4 Configuring the control in STEP 7 Lite 4.1 What is a STEP 7 Lite project? Opening the “conveyor” project 4 Configuring the control in STEP 7 Lite4.2 Opening a STEP 7 Lite project 1. Start STEP 7 LiteCreating the module configuration 4.3 Reproducing the module configuration in STEP 7 Lite1. Create a new S7-300 station 4 Configuring the control in STEP 7 Lite Page 4 Configuring the control in STEP 7 Lite Setting the parameters of the CPU 312C 1. Set the amount of retentive bit memory to “0”Saving the project 1. Save the project4.4 Establishing the online connection between the PC and CPU 312C Establishing the online connectionPerforming a memory reset on the CPU 312C 4.5 Downloading and checking the module configuration to the CPU 312C1. Delete the old program blocks and configurations from the CPU 312C Downloading the module configuration to the CPU 312C Checking the module configuration Page 5 Opening the program on the PC 5.1 What is a program? 5 Opening the program on the PC 5.2 Opening a program1. Open the program Page 6 Performing a test run 6.1 Downloading the project to the CPU 312C 6.2 Starting the test run 1. Set the mode switch of the CPU 312C to “RUN”6 Performing a test run 2. Press the green momentary con- tact switch to start the motor The output LED 0.5 lights up. The input LED 0.3 lights up The motor is switched offThe output LED 0.3 goes out Page 7 Congratulations Want to know more about SIMATIC S7-300? Contact us 8 Additional information 8.1 Diagnostics / correction of errors 8.2 Additional documentation 8 Additional informationName of manual DescriptionService & Support on the Internet 8.3 SIMATIC Technical SupportPage 8 Additional information
Related manuals