8.1 Diagnostics / correction of errors

8.1 Diagnostics / correction of errors

Incorrect operation, faulty wiring, or an incorrect hardware configuration can cause errors. The CPU 312C displays such errors with the group error LED SF following a memory reset. For information on how to analyze errors and mes- sages, refer to the “S7-300, CPU 31xC and CPU 31x: Installation” operating instructions. This manual is included in the SIMATIC Manual Collection, which is enclosed in the S7-300 starter kit.

The PC Adapter USB uses LEDs to indicate error states. To diagnose these errors, refer to the electronic “PC Adapter USB” Manual. You can find this man- ual on the installation CD for the PC Adapter USB.

59

SIMATIC S7-300 Getting Started for First Time Users Getting Started, 04/2007, 6ZB5310-0NC02-0BA0

Image 63
Contents 04/2007 SIMATIC S7-300 Getting Started for First Time UsersOrder No. 6ZB5310-0NC02-0BA0 Safety Guidelines DangerQualified Personnel Prescribed Usage TrademarksDisclaimer of Liability Page 7 Congratulations Contents1 Welcome To accomplish this, you will perform the following tasks You will need a micro 1 WelcomeValidity PrerequisitesSiemens Materials and toolsOrder number QuantityIn addition, you will need the following components You can also use theVDE 0805 / EN 60950 / IEC 950 or VDE 0106 Part Page 2 Preparing the PC Installing STEP 7 Lite Installing the driver for the PC Adapter USBOpen the installation file and follow the instructions Setting the interface 1. Open the dialog for setting the PG/PC interface2 Preparing the PC Page 2 Preparing the PC Page 3 Installing and wiring the hardware 3.1 What components are required? 2. Connect the mounting rail to the ground wire 3.2 Installing the components3 Installing and wiring the hardware Installing and grounding the mounting railing the screws hand-tight Installing modules on the mounting rail1. Install the power supply, tighten 2. Install the CPU 312C2. Remove the insulation and press 3.3 Wiring the componentsPreparing the cables 1. Cut the cables to the desired3. Secure the power cable Wiring the CPU 312C and the power supply1. Prepare the power cable 2. Connect the power cable to the power supply1. Connect the momentary contact switches to the digital inputs Wiring the momentary contact switches1. Connect the power supply for the digital inputs Wiring the motor2. Wire the motor, if available. This step is optional Connecting the front panel connector 2. If necessary, change the switch position for the line voltage Checking the line voltage settingConnecting the CPU 312C and the PC 3.4 Commissioning the hardware1. Connect the USB cable to the PC Adapter and your PC 2. Close the front panel 1. Connect the supply cable to the supply system Supplying power to the CPU 312C3 Installing and wiring the hardware 3. Set the main switch of the power supply to “ON” Testing the connections Page 4 Configuring the control in STEP 7 Lite 4.1 What is a STEP 7 Lite project? 1. Start STEP 7 Lite 4 Configuring the control in STEP 7 Lite4.2 Opening a STEP 7 Lite project Opening the “conveyor” project4.3 Reproducing the module configuration in STEP 7 Lite Creating the module configuration1. Create a new S7-300 station 4 Configuring the control in STEP 7 Lite Page 4 Configuring the control in STEP 7 Lite 1. Set the amount of retentive bit memory to “0” Setting the parameters of the CPU 312C1. Save the project Saving the projectEstablishing the online connection 4.4 Establishing the online connection between the PC and CPU 312C4.5 Downloading and checking the module configuration to the CPU 312C Performing a memory reset on the CPU 312C1. Delete the old program blocks and configurations from the CPU 312C Downloading the module configuration to the CPU 312C Checking the module configuration Page 5 Opening the program on the PC 5.1 What is a program? 5.2 Opening a program 5 Opening the program on the PC1. Open the program Page 6 Performing a test run 6.1 Downloading the project to the CPU 312C 1. Set the mode switch of the CPU 312C to “RUN” 6.2 Starting the test run6 Performing a test run 2. Press the green momentary con- tact switch to start the motor The motor is switched off The output LED 0.5 lights up. The input LED 0.3 lights upThe output LED 0.3 goes out Page 7 Congratulations Want to know more about SIMATIC S7-300? Contact us 8 Additional information 8.1 Diagnostics / correction of errors 8 Additional information 8.2 Additional documentationDescription Name of manual8.3 SIMATIC Technical Support Service & Support on the InternetPage 8 Additional information
Related manuals
Manual 244 pages 25.52 Kb