4.4Establishing the online connection between the PC and CPU 312C

4.4Establishing the online connection between the PC and CPU 312C

You must establish an online connection between the PC and CPU 312C for the following:

Downloading and testing the control programs

Displaying and changing the operating state of the CPU 312C

Displaying the module status

Hardware diagnostics

To establish an online connection, you must connect the PC and CPU 312C to one another via the MPI interface.

Establishing the online connection

STEP 7 Lite attempts to establish the online connection on startup.

If the connection exists, the operating state of the CPU 312C is displayed in the status bar as “STOP”.

If no connection exists, the status bar displays “Disconnected”.

1.If the connection does not exist, establish the connection between the CPU 312C and your PC.

41

SIMATIC S7-300 Getting Started for First Time Users Getting Started, 04/2007, 6ZB5310-0NC02-0BA0

Image 45
Contents 04/2007 SIMATIC S7-300 Getting Started for First Time UsersOrder No. 6ZB5310-0NC02-0BA0 Safety Guidelines DangerQualified Personnel Prescribed Usage TrademarksDisclaimer of Liability Page 7 Congratulations Contents1 Welcome To accomplish this, you will perform the following tasks Validity 1 WelcomePrerequisites You will need a microOrder number Materials and toolsQuantity SiemensIn addition, you will need the following components You can also use theVDE 0805 / EN 60950 / IEC 950 or VDE 0106 Part Page 2 Preparing the PC Installing STEP 7 Lite Installing the driver for the PC Adapter USBOpen the installation file and follow the instructions Setting the interface 1. Open the dialog for setting the PG/PC interface2 Preparing the PC Page 2 Preparing the PC Page 3 Installing and wiring the hardware 3.1 What components are required? 3 Installing and wiring the hardware 3.2 Installing the componentsInstalling and grounding the mounting rail 2. Connect the mounting rail to the ground wire1. Install the power supply, tighten Installing modules on the mounting rail2. Install the CPU 312C ing the screws hand-tightPreparing the cables 3.3 Wiring the components1. Cut the cables to the desired 2. Remove the insulation and press1. Prepare the power cable Wiring the CPU 312C and the power supply2. Connect the power cable to the power supply 3. Secure the power cable1. Connect the momentary contact switches to the digital inputs Wiring the momentary contact switches1. Connect the power supply for the digital inputs Wiring the motor2. Wire the motor, if available. This step is optional Connecting the front panel connector 2. If necessary, change the switch position for the line voltage Checking the line voltage settingConnecting the CPU 312C and the PC 3.4 Commissioning the hardware1. Connect the USB cable to the PC Adapter and your PC 2. Close the front panel 1. Connect the supply cable to the supply system Supplying power to the CPU 312C3 Installing and wiring the hardware 3. Set the main switch of the power supply to “ON” Testing the connections Page 4 Configuring the control in STEP 7 Lite 4.1 What is a STEP 7 Lite project? 4.2 Opening a STEP 7 Lite project 4 Configuring the control in STEP 7 LiteOpening the “conveyor” project 1. Start STEP 7 Lite4.3 Reproducing the module configuration in STEP 7 Lite Creating the module configuration1. Create a new S7-300 station 4 Configuring the control in STEP 7 Lite Page 4 Configuring the control in STEP 7 Lite 1. Set the amount of retentive bit memory to “0” Setting the parameters of the CPU 312C1. Save the project Saving the projectEstablishing the online connection 4.4 Establishing the online connection between the PC and CPU 312C4.5 Downloading and checking the module configuration to the CPU 312C Performing a memory reset on the CPU 312C1. Delete the old program blocks and configurations from the CPU 312C Downloading the module configuration to the CPU 312C Checking the module configuration Page 5 Opening the program on the PC 5.1 What is a program? 5.2 Opening a program 5 Opening the program on the PC1. Open the program Page 6 Performing a test run 6.1 Downloading the project to the CPU 312C 1. Set the mode switch of the CPU 312C to “RUN” 6.2 Starting the test run6 Performing a test run 2. Press the green momentary con- tact switch to start the motor The motor is switched off The output LED 0.5 lights up. The input LED 0.3 lights upThe output LED 0.3 goes out Page 7 Congratulations Want to know more about SIMATIC S7-300? Contact us 8 Additional information 8.1 Diagnostics / correction of errors 8 Additional information 8.2 Additional documentationDescription Name of manual8.3 SIMATIC Technical Support Service & Support on the InternetPage 8 Additional information