Technical data of CPU 31x 7.6 CPU 317-2 DP

Technical data

Number of connections

32

can be used for

 

PG communication

Max. 31

 

Reserved (default)

1

 

Configurable

1 to 31

OP communication

Max. 31

 

Reserved (default)

1

 

Configurable

1 to 31

S7-based communication

Max. 30

 

Reserved (default)

0

 

Configurable

0 to 30

Routing

Yes (max. 8)

Interfaces

 

1st interface

 

Type of interface

Integrated RS485 interface

Physics

RS 485

electrically isolated

Yes

Interface power supply

max. 200 mA

(15 to 30 VDC)

 

Functionality

 

MPI

Yes

PROFIBUS DP

Yes

Point-to-point communication

No

MPI

 

 

Services

 

PG/OP communication

Yes

Routing

Yes

Global data communication

Yes

S7 basic communication

Yes

S7 communication

 

 

As server

Yes

 

As client

No (but via CP and loadable FBs)

Transmission rates

Max. 12 Mbps

DP master

 

Services

 

PG/OP communication

Yes

Routing

Yes

Global data communication

No

S7 basic communication

No

S7 communication

No

Constant bus cycle time

Yes

SYNC/FREEZE

Yes

DPV1

Yes

7-30

CPU 31xC and CPU 31x, Technical data

Manual, Edition 08/2004, A5E00105475-05

Image 196
Contents Edition 08/2004 ManualPreface Safety Guidelines Purpose of the Manual Required basic knowledgeArea of application IiiApprovals CE labelTick mark StandardsDocumentation classification This manual is part of the S7-300 documentation packageRecycling and Disposal Additional information requiredTable of contents Table of contents Index-1 Tables Retentivity of the RAM Table A-1 XiiOverview Selecting and configuringInformation on Is available Guide to the S7-300 documentation CPU performance Programming Manual From Profibus DP to Profinet Operating and display elements of CPU 31xC Operating and display elements CPU 31xCX11 X12 Slot for the Simatic Micro Memory Card MMC Integrated I/Os of CPU 31xC CPU 314C-2 PtP, for exampleMode selector switch Power supply connectionReference Differences between the CPUsStatus and Error Indicators CPU 31xC LED designation Color MeaningOperating and display elements CPU 312, 314, 315-2 DP Operating and display elements CPUOperating and display elements Mode selector switch is used to set the CPU operating mode Operating and display elements CPU 317-2 DP Use the mode selector switch to set the CPU operating mode Operating and display elements CPU 31x-2 PN/DP Slot for the Simatic Micro Memory Card MMC General status and error displays Status and error displays of the CPUDisplays for the X1 and X2 interfaces CPU 31xC and CPU 31x, Technical data Interfaces Multi-Point Interface MPIAvailability PropertiesDevices capable of MPI communication Operating modes for CPUs with two DP interfacesS7-300 / S7-400 with MPI interface S7-200 19.2 kbps only MPI/DP interface Profibus DP interfaceDevices capable of Profibus DP communication Connecting to Industrial EthernetRequirements Devices capable of Profinet PN communication Properties of Profinet interfaceSee also Profinet IO SystemPoint to Point PtP Transmission rateDrivers Devices capable of PtP communicationCommunication services Overview of communication servicesSelecting the communication service Overview of communication servicesOP communication PG communicationData exchanged by means of S7 basic communication Use in server mode for Configuration5 S7 communication Use as clientReduction ratio Global data communication MPI onlySend and receive conditions Routing GD resources of the CPUsCPU 315-2 DP 315-2 PN/DPRouting network nodes MPI DP Routing network nodes MPI DP Ethernet Number of routed connections2 DP 317-2 PN/DPRequirements Configuration in Step Real installationRouting Example of a TeleService application PtP communication What is PROFINET?? Data consistencyCommunication via Profinet only CPU 31x-2 PN/DP With PUT/GET functionsObjectives in Profinet What is Profinet CBA Component based Automation?Implementation of Profinet by us Further Information Extent of Profinet CBA and Profinet IO,2DWD9LHZ 352,17,2 Following graphic shows the new functions of Profinet IO Profinet IO System Extended Functions of Profinet IOGraphic displays Compatibility of the New Blocks Blocks in Profinet IO Chapter ContentProfinet PN Blocks NewDetailed Information Compatibility of the new SSLs System status lists SSLs in Profinet IO Chapter ContentApplicability How to use open IE communication Data block for the configuration of the connectionOpen communication via Industrial Ethernet Requirements FunctionalityDisconnecting Establishing a connection for communicationData exchange Communication interruptionsS7 connections Snmp communication service Availability1 S7 connection as communication path Reservation during configuration Assignment of S7 connectionsConnection points Transition pointAllocating connection resources to Ocms services Assigning connections in the programTime sequence for allocation of S7 connection resources ExampleDistribution and availability of S7 connection resources Communication service DistributionDistribution of connection resources Availability of connection resources Total number Reserved for Free Connection S7 connectionsS7 basic ResourcesConnection resources for routing Number of connection resources for routingExample of a CPU 314C-2 DP Example for a CPU 317-2 PN/DPRequirement for using the DPV1 functionality with DP slaves DPV1Definition DPV1 Extended functions of DPV1Interrupt blocks with DPV1 functionality System blocks with DPV1 functionalityProfibus DP FunctionalityCommunication 3.4 DPV1 Memory areas and retentivity CPU memory areasThree memory areas of your CPU Load memoryRetentivity of the load memory, system memory and RAM System memoryRAM Retentive data in load memoryRetentivity of memory objects Retentive data in RAMRetentive behavior of memory objects Retentive behavior of a DB for CPUs with firmwareRetentive behavior of a DB for CPUs with firmware = RUN-STOPAddress areas of system memory Address areas of system memoryProcess image Address areas DescriptionProcess image update TimeConfigurable process image with CPU317 FW V2.3.0 or higher Local data Retentivity of the load memory, system memory and RAMMMC as memory module for the CPU Properties of the Micro Memory Card MMCProperties of an MMC MMC copy protection Useful life of an MMCMemory functions General Memory functionsLoading user program from Micro Memory Card MMC to the CPU Memory functionsDownload of new blocks or delta downloads Handling with modulesUploading blocks CPU memory reset and restart CPU memory resetDeleting blocks Compressing blocksRestart warm start Recipes IntroductionProcessing sequence Recipe Recipe nMemory concept Memory functions Measured values Measured value log filesWorking memory Evaluation of measured values Backup of project data to a Micro Memory Card MMC Function principleMemory concept Memory functions Reference Cycle time OverviewReference Execution time Cycle time OverviewMeaning of the term cycle time Time slice modelTime slices 1 ms each Sequence of cyclic program processingStep Sequence Extending the cycle time Process image update Calculating the cycle timeExtending the user program processing time + 60 μs per rackConst Portions CPU FactorProcess Diagnostic Time-of-day Cycle control at the scan cycle check point CCPWatchdog InterruptExtension of the cycle time due to error Programming errors Access errorsDifferent cycle times Block processing times may fluctuateCommunication load Maximum cycle timeExample 20 % communication load Example 50 % communication loadInfluence on the physical cycle time Physical cycle time depending on communication loadTips Configuration during parameter assignment Cycle extension through component-based automation CBARuntimes Extending the OB1 cycle timeProfibus Base load through Profibus devices Additional marginal conditionsTips and notes Update times for Profinet IO Response timeDefinition of response time Fluctuation widthDP cycle times in the Profibus DP network 17 msShortest response time Conditions for the shortest response timeCalculation Shortest response time is the sumDelay of inputs + DP cycle time at Profibus DP Delay of outputs + DP cycle time at Profibus DPLongest response time Conditions for the longest response timeReducing the response time with direct I/O access Reducing the response timeLongest response time is the sum Shortest response time Longest response timeCycle time Calculating method for calculating the cycle/response timeCycle extension through component-based automation CBA Response time Shortest response time Longest response timeInterrupt response time Process/diagnostic interrupt response times of the CPUsDefinition of interrupt response time Signal modules Tv 200 μs + 1000 μs x n%Reproducibility of delay interrupts and watchdog interrupts Process interrupt processingDefinition of Reproducibility ReproducibilitySample calculations Example of cycle time calculationSample of response time calculation Calculating the longest response timeCalculation of the longest response time Example of interrupt response time calculation Cycle and reaction times 5.6 Sample calculations General technical data Dimensions of CPU 31xCWidth of CPU WidthTechnical data of the Micro Memory Card MMC Plug-in Simatic Micro Memory CardsMaximum number of loadable blocks in the MMC Following memory modules are availableTechnical data CPU 312CData areas and their retentivity Technical dataAddress areas I/O S7 signaling functions Technical data AssemblyTesting and commissioning functions Communication functions Interfaces 1st interfaceTechnical data Functionality DimensionsProgramming Integrated functionsTechnical data of CPU 31xC 6.3 CPU 313C CPU 313CTechnical data Timers/counters and their retentivity Technical data Address areas I/O Technical data MPI Technical data Integrated I/O KHz see the Manual Technological FunctionsTechnical data CPU 313C-2 PtP CPU 313C-2 DP CPU and version CPU 313C-2 PtP and CPU 313C-2 DPMemory CPU 313C-2 PtP CPU 313C-2 DP Execution times CPU 313C-2 PtP CPU 313C-2 DPBlocks CPU 313C-2 PtP CPU 313C-2 DP Assembly CPU 313C-2 PtP CPU 313C-2 DPAddress areas I/O CPU 313C-2 PtP CPU 313C-2 DP S7 signaling functions CPU 313C-2 PtP CPU 313C-2 DP Technical data CPU 313C-2 PtP CPU 313C-2 DPTime-of-day CPU 313C-2 PtP CPU 313C-2 DP Interfaces CPU 313C-2 PtP CPU 313C-2 DP 1st interface DP master Technical data CPU 313C-2 PtP CPU 313C-2 DP DP slave GSD filePoint-to-point communication Programming CPU 313C-2 PtP CPU 313C-2 DPDimensions CPU 313C-2 PtP CPU 313C-2 DP Voltages and currents CPU 313C-2 PtP CPU 313C-2 DPTechnical data CPU 314C-2 PtP CPU 314C-2 DP CPU and version CPU 314C-2 PtP and CPU 314C-2 DPMemory CPU 314C-2 PtP CPU 314C-2 DP Execution times CPU 314C-2 PtP CPU 314C-2 DPBlocks CPU 314C-2 PtP CPU 314C-2 DP Assembly CPU 314C-2 PtP CPU 314C-2 DPAddress areas I/O CPU 314C-2 PtP CPU 314C-2 DP S7 signaling functions CPU 314C-2 PtP CPU 314C-2 DP Technical data CPU 314C-2 PtP CPU 314C-2 DPTime-of-day CPU 314C-2 PtP CPU 314C-2 DP Interfaces CPU 314C-2 PtP CPU 314C-2 DP 1st interface 2nd interface CPU 314C-2 PtP CPU 314C-2 DP Programming CPU 314C-2 PtP CPU 314C-2 DP Technical data CPU 314C-2 PtP CPU 314C-2 DP DP slaveIntegrated I/O CPU 314C-2 PtP CPU 314C-2 DP Dimensions CPU 314C-2 PtP CPU 314C-2 DP Voltages and currents CPU 314C-2 PtP CPU 314C-2 DPCPU 312C Pin-out of the integrated DI/DO connector Technical data of the integrated I/OArrangement and usage of integrated I/Os Block diagram of the integrated digital I/O Standard Interrupt Count Posi-1 Input Tioning 1L+ 2L+ Controller See also Wiring of the current/voltage inputs Analog I/OMeasurement principle Maximum frequency of the input signal is 400 HzIntegrated hardware low-pass filter Input filters software filter Principle of interference suppression with Step50 Hz interference suppression Inputs not connected Outputs not connectedValue range Default Range of efficiency ConfigurationParameters of standard DI Byte Byte 3 reservedByte 6 Byte 7 reservedParameters of standard do Parameters of standard AIThere are no parameters for standard digital outputs See also .3 in the Module Data Reference ManualParameters Value range Default Range of efficiency Parameters of standard AO\WH  \WH \WH  \WH \WH  Parameter for technological functions\WH  Interrupts Interrupt inputsStart information for OB40 Byte Variables Data type DescriptionDiagnostics Digital inputsStandard I/O Technological functionsFunctions Manual Fast digital outputs Digital outputsTechnological functions use fast digital outputs 13 Technical data of digital outputs CPU 31xC and CPU 31x, Technical data Technical data Module-specific data Analog inputsVoltage, currents, potentials Analog value generationStatus, interrupts, diagnostics Interference suppression, error limitsEncoder selection data Analog outputs Actuator selection data Technical data of CPU 31xC CPU 31xC and CPU 31x, Technical data Technical data of CPU Dimensions of CPUTechnical data of CPU 31x 7.1 General technical data CPU Technical data Data areas and their retentivity Technical data Technical data Communication functions Mounting dimensions W x H x D mm 40 x 125 x Weight 270 g Technical data for the CPU Technical data Data areas and their retentivity Technical data Number of entries not configurable Max Mounting dimensions W x H x D mm 40 x 125 x Weight 280 g CPU 315-2 DP Technical data Data areas and their retentivity Technical data Diagnostic buffer Yes Number of entries not configurable Max 2nd interface Technical data DP slave CPU 315-2 PN/DP Technical data Technical data Assembly Parameters of SFBs/FBs and SFC/FC of the S7 CBA at 50 % communication load Transmission speed Up to 12 Mbps Number of DP slaves 124 Profinet IO Technical data Voltages and currents CPU 317-2 DPTechnical data Timers/counters and their retentivity Technical data Technical data S7 signaling functions CPU 317-2 DPMPI DP slave Except for DP slave at both interfaces GSD file CPU 317-2 PN/DP Technical data Analog channels 4096/4096 Those local 256/256 Communication functions Routing Interface X1 configured as Yes MPI Profinet IO Technical data Voltages and currents Information about upgrading to a CPU 31xC or CPU Area of applicabilityWho should read this information? If you have used one of the following CPUs in the pastChanged behavior of certain SFCs SFC 56, SFC 57 and SFC 13 which work asynchronouslyDPV1 Hereafter calledSFC 20 Blkmov SFC 54 RddparmSFCs that may return other results Activating / deactivating DP slaves via SFCPrevious response by the CPU with Stop status New response by the CPUConverting the diagnostic addresses of DP slaves Converting the diagnostic addresses of DP slavesRuntimes that change while the program is running Runtimes that change while the program is runningReusing existing hardware configurations Reusing existing hardware configurationsReplacing a CPU 31xC/31x Replacing a CPU 31xC/31xConsistent data 10 PG/OP functions Load memory concept for the CPU 31xC/31xRouting for the CPU 31xC/31x as an intelligent slave Changed retentive behavior for CPUs with firmware = Changed retentive behavior for CPUs with firmware =Procedure Asic Backup memory BusBus segment Clock flag bitsCPU Default Router Data, temporaryDeterminism DeviceDPV1 Ertec Function block Functional groundGD circuit GD elementGSD file HubIndustrial Ethernet Instance data blockInterrupt, delay Interrupt, diagnosticInterrupt, update Interrupt, processLAN MPI NCM PCNesting depth NetworkNon-isolated OB priorityPLC PNOProfibus Profibus DPProfinet Profinet AsicProfinet CBA Profinet ComponentProfinet IO Proxy Real TimeReduction factor Reference groundSFB SFCSimatic Simatic NCM PCSimatic NET SnmpStep System diagnostics TimerTimers System functionToken TopologyTwisted Pair UngroundedWAN Glossary-23Glossary-24 Index Index Index-3 Index