Dell 4691901 owner manual System Setup Options

Page 35

Action

Keystroke

 

 

Exit BIOS

<Esc> — Remain in Setup, Save/Exit, Discard/Exit

Change a setting

Left or right-arrow key

Select field to change

<Enter>

Cancel modification

<Esc>

Reset defaults

<Alt><F> or Load Defaults menu option

System Setup Options

NOTE: Depending on the computer and its installed devices, the items listed in this section may or may not appear.

General

System Information

Displays the following information:

 

• System Information: Displays BIOS Version, Service Tag, Asset Tag, Ownership

 

 

Date, Manufacture Date, and the Express Service Code.

 

• Memory Information: Displays Memory Installed, Memory Available, Memory

 

 

Speed, Memory Channels Mode, Memory Technology, DIMM 1 Size, DIMM 2

 

 

Size, DIMM 3 Size, and DIMM 4 Size.

 

• Processor Information: Displays Processor Type, Core Count, Processor ID,

 

 

Current Clock Speed, Minimum Clock Speed, Maximum Clock Speed,

 

 

Processor L2 Cache, Processor L3 Cache, HT Capable, and 64-Bit Technology.

 

• PCI Information: Displays SLOT1, SLOT2, SLOT3, SLOT4

 

• Device Information: Displays SATA-0, SATA-1, SATA-2, SATA-3, and LOM MAC

 

 

Address.

Boot Sequence

Allows you to specify the order in which the computer attempts to find an operating

 

system from the devices specified in this list.

 

USB Storage Device

 

CD/DVD/CD-RW Drive

 

Onboard NIC

Date/Time

Allows you to set the date and time settings. Changes to the system date and time take

 

effect immediately.

 

 

 

System Configuration

 

 

 

 

Integrated NIC

Allows you to enable or disable the integrated network card. You can set the integrated

 

NIC to:

 

 

Disabled

 

Enabled (default)

 

Enabled w/PXE

 

Enabled w/ImageServer

NOTE: Depending on the computer and its installed devices, the items listed in this section may or may not appear.

Serial Port

Allows you to set the serial port settings. You can set the serial port to:

35

Image 35
Contents Regulatory Model D07D Regulatory Type D07D001 Dell Inc Contents Troubleshooting System SetupContacting Dell SpecificationsPage Before Working Inside Your Computer Working on Your ComputerAfter Working Inside Your Computer Turning Off Your ComputerRelated Links Installing The CoverRemoving the Cover Removing the Expansion Card Installing The Front BezelRemoving the Front Bezel Page Removing the Optical Drive Installing The Expansion CardRemoving the Hard Drive Installing The Optical DrivePage Removing the Memory Installing The Hard DriveRemoving the Chassis Intrusion Switch Installing The MemoryRemoving The Speaker Installing The Chassis Intrusion SwitchInstalling The Speaker Removing The Heat Sink and Processor Installing The Heat Sink and Processor Removing The Power-Switch Cable Removing The Coin-Cell BatteryInstalling The Coin-Cell Battery Installing The Power-Switch Cable Removing The Front Thermal Sensor Removing The System Fan Installing The Front Thermal SensorInstalling The System Fan Removing The Input/Output Panel Installing The System FanRemove the Input/Output panel Installing The Input/Output PanelRemoving The Power Supply Disconnect the 4-pin power cable from the system boardPage Installing The Power Supply Remove the expansion cards Removing the System BoardRemove the system board from the chassis Installing the System BoardRemoving The PSU Thermal Sensor Installing The PSU Thermal Sensor CtrlAltF8 One-time boot and diagnostics utility menu F12 System SetupBoot Menu Boot Menu EnhancementsAction Keystroke Beep Codes and Text Error MessagesTiming Key Sequences NavigationSystem Setup Options Security Password Changes Password BypassPassword prompts during a system restart They are set. This option is disabled by defaultPerformance Power ManagementVirtualization Support Enable F12 Boot menu enabled by defaultMaintenance Post BehaviorSystem Logs Power Button Diagnostic LEDsDiagnostic Light Patterns Troubleshooting Steps Possible system board failure has occurred Re-seat the 2x2 power connector from the power supply unitPower Button Problem Description If the problem persists, the system board is faultyReinstalled all modules without error Problem Description Troubleshooting Steps Code Cause Microprocessor register failure Beep CodesCode Cause Code Cause DMA initialization failureCode Through Cause Code Cause Time-of-day clock stopped Error MessagesAddress mark not found Code Cause No time tick Shutdown failure Gate A20 failureData error Alert! Security override Jumper is installedBad command or file name Bad error-correction code ECC on disk readDiskette read failure Diskette subsystem reset failedHard-disk drive configuration error Diskette drive 0 seek failureKeyboard failure Invalid configuration information-please run Setup programInvalid Memory configuration, please populate DIMM1 Memory allocation errorNon-system disk or disk error No boot device availableNo boot sector on hard-disk drive No timer tick interruptTime-of-day not set-please run the System Setup program Read faultReset failed Seek error\ is not accessible. The device is not ready Unexpected interrupt in protected modeWrite fault Write fault on selected driveMemory SpecificationSystem Information ProcessorCards AudioNetwork Expansion BusAudio Back Panel Mini-Tower/Desktop External ConnectorsSystem Board Connectors Mini-Tower Two Desktop One Small Form FactorControls and Lights Environmental Physical Height Width Depth WeightPage Visit support.dell.com Contacting Dell