Dell 4691901 Alert! Security override Jumper is installed, Attachment failed to respond

Page 49

Alert! Previous attempts at booting this system have failed at checkpoint [nnnn]. For help in resolving this problem, please note this checkpoint and contact Dell Technical Support.

Description The computer failed to complete the boot routine three consecutive times for the same error. Contact Dell and report the checkpoint code (nnnn) to the support technician

Alert! Security override Jumper is installed.

Description The MFG_MODE jumper has been set and AMT Management features are disabled until it is removed.

Attachment failed to respond

Description The floppy or hard drive controller cannot send data to the associated drive.

Bad command or file name

Description Ensure that you have spelled the command correctly, put spaces in the proper place, and used the correct pathname.

Bad error-correction code (ECC) on disk read

Description The floppy or hard drive controller detected an uncorrectable read error.

Controller has failed

Description

The hard drive or the associated controller is defective.

Data error

Description The floppy or hard drive cannot read the data. For the Windows operating system, run the chkdsk utility to check the file structure of the floppy or hard drive. For any other operating system, run the appropriate corresponding utility.

Decreasing available memory

Description One or more memory modules may be faulty or improperly seated. Re-install the memory modules and, if necessary, replace them.

49

Image 49
Contents Regulatory Model D07D Regulatory Type D07D001 Dell Inc Contents Troubleshooting System SetupContacting Dell SpecificationsPage Before Working Inside Your Computer Working on Your ComputerAfter Working Inside Your Computer Turning Off Your ComputerRemoving the Cover Installing The CoverRelated Links Removing the Front Bezel Installing The Front BezelRemoving the Expansion Card Page Removing the Optical Drive Installing The Expansion CardRemoving the Hard Drive Installing The Optical DrivePage Removing the Memory Installing The Hard DriveRemoving the Chassis Intrusion Switch Installing The MemoryRemoving The Speaker Installing The Chassis Intrusion SwitchInstalling The Speaker Removing The Heat Sink and Processor Installing The Heat Sink and Processor Installing The Coin-Cell Battery Removing The Coin-Cell BatteryRemoving The Power-Switch Cable Installing The Power-Switch Cable Removing The Front Thermal Sensor Removing The System Fan Installing The Front Thermal SensorInstalling The System Fan Removing The Input/Output Panel Installing The System FanRemoving The Power Supply Installing The Input/Output PanelDisconnect the 4-pin power cable from the system board Remove the Input/Output panelPage Installing The Power Supply Remove the expansion cards Removing the System BoardRemoving The PSU Thermal Sensor Installing the System BoardRemove the system board from the chassis Installing The PSU Thermal Sensor Boot Menu System SetupBoot Menu Enhancements CtrlAltF8 One-time boot and diagnostics utility menu F12Timing Key Sequences Beep Codes and Text Error MessagesNavigation Action KeystrokeSystem Setup Options Security Password prompts during a system restart Password BypassThey are set. This option is disabled by default Password ChangesPerformance Power ManagementMaintenance Enable F12 Boot menu enabled by defaultPost Behavior Virtualization SupportSystem Logs Diagnostic Light Patterns Diagnostic LEDsPower Button Troubleshooting Steps Power Button Problem Description Re-seat the 2x2 power connector from the power supply unitIf the problem persists, the system board is faulty Possible system board failure has occurredReinstalled all modules without error Problem Description Troubleshooting Steps Code Cause Microprocessor register failure Beep CodesCode Through Cause Code Cause DMA initialization failureCode Cause Address mark not found Error MessagesCode Cause No time tick Shutdown failure Gate A20 failure Code Cause Time-of-day clock stoppedBad command or file name Alert! Security override Jumper is installedBad error-correction code ECC on disk read Data errorHard-disk drive configuration error Diskette subsystem reset failedDiskette drive 0 seek failure Diskette read failureInvalid Memory configuration, please populate DIMM1 Invalid configuration information-please run Setup programMemory allocation error Keyboard failureNo boot sector on hard-disk drive No boot device availableNo timer tick interrupt Non-system disk or disk errorReset failed Read faultSeek error Time-of-day not set-please run the System Setup programWrite fault Unexpected interrupt in protected modeWrite fault on selected drive \ is not accessible. The device is not readySystem Information SpecificationProcessor MemoryNetwork AudioExpansion Bus CardsSystem Board Connectors External ConnectorsMini-Tower Two Desktop One Small Form Factor Audio Back Panel Mini-Tower/DesktopControls and Lights Environmental Physical Height Width Depth WeightPage Visit support.dell.com Contacting Dell