Dell 4691901 owner manual System Setup, Troubleshooting

Page 4

Installing The Power Supply

29

Removing the System Board

30

Installing the System Board

31

Removing The PSU Thermal Sensor

31

Installing The PSU Thermal Sensor

32

3 System Setup

33

System Setup

33

Boot Menu

33

Boot Menu Enhancements

33

Timing Key Sequences

34

Beep Codes and Text Error Messages

34

Navigation

34

System Setup Options

35

4 Troubleshooting

41

Diagnostic LEDs

41

Diagnostic Light Patterns

41

Beep Codes

46

Error Messages

48

Address mark not found

48

Alert! Previous attempts at booting this system have failed at checkpoint [nnnn]. For help in resolving

 

this problem, please note this checkpoint and contact Dell Technical Support

49

Alert! Security override Jumper is installed

49

Attachment failed to respond

49

Bad command or file name

49

Bad error-correction code (ECC) on disk read

49

Controller has failed

49

Data error

49

Decreasing available memory

49

Diskette drive 0 seek failure

50

Diskette read failure

50

Diskette subsystem reset failed

50

Gate A20 failure

50

General failure

50

Hard-disk drive configuration error

50

Hard-disk drive controller failure

50

Hard-disk drive failure

50

Hard-disk drive read failure

50

Invalid configuration information-please run SETUP program

51

Invalid Memory configuration, please populate DIMM1

51

Keyboard failure

51

Image 4
Contents Regulatory Model D07D Regulatory Type D07D001 Dell Inc Contents System Setup TroubleshootingSpecifications Contacting DellPage Working on Your Computer Before Working Inside Your ComputerTurning Off Your Computer After Working Inside Your ComputerRemoving the Cover Installing The CoverRelated Links Removing the Front Bezel Installing The Front BezelRemoving the Expansion Card Page Installing The Expansion Card Removing the Optical DriveInstalling The Optical Drive Removing the Hard DrivePage Installing The Hard Drive Removing the MemoryInstalling The Memory Removing the Chassis Intrusion SwitchInstalling The Chassis Intrusion Switch Removing The SpeakerInstalling The Speaker Removing The Heat Sink and Processor Installing The Heat Sink and Processor Installing The Coin-Cell Battery Removing The Coin-Cell BatteryRemoving The Power-Switch Cable Installing The Power-Switch Cable Removing The Front Thermal Sensor Installing The Front Thermal Sensor Removing The System FanInstalling The System Fan Installing The System Fan Removing The Input/Output PanelInstalling The Input/Output Panel Removing The Power SupplyDisconnect the 4-pin power cable from the system board Remove the Input/Output panelPage Installing The Power Supply Removing the System Board Remove the expansion cardsRemoving The PSU Thermal Sensor Installing the System BoardRemove the system board from the chassis Installing The PSU Thermal Sensor System Setup Boot MenuBoot Menu Enhancements CtrlAltF8 One-time boot and diagnostics utility menu F12Beep Codes and Text Error Messages Timing Key SequencesNavigation Action KeystrokeSystem Setup Options Security Password Bypass Password prompts during a system restartThey are set. This option is disabled by default Password ChangesPower Management PerformanceEnable F12 Boot menu enabled by default MaintenancePost Behavior Virtualization SupportSystem Logs Diagnostic Light Patterns Diagnostic LEDsPower Button Troubleshooting Steps Re-seat the 2x2 power connector from the power supply unit Power Button Problem DescriptionIf the problem persists, the system board is faulty Possible system board failure has occurredReinstalled all modules without error Problem Description Troubleshooting Steps Beep Codes Code Cause Microprocessor register failureCode Through Cause Code Cause DMA initialization failureCode Cause Error Messages Address mark not foundCode Cause No time tick Shutdown failure Gate A20 failure Code Cause Time-of-day clock stoppedAlert! Security override Jumper is installed Bad command or file nameBad error-correction code ECC on disk read Data errorDiskette subsystem reset failed Hard-disk drive configuration errorDiskette drive 0 seek failure Diskette read failureInvalid configuration information-please run Setup program Invalid Memory configuration, please populate DIMM1Memory allocation error Keyboard failureNo boot device available No boot sector on hard-disk driveNo timer tick interrupt Non-system disk or disk errorRead fault Reset failedSeek error Time-of-day not set-please run the System Setup programUnexpected interrupt in protected mode Write faultWrite fault on selected drive \ is not accessible. The device is not readySpecification System InformationProcessor MemoryAudio NetworkExpansion Bus CardsExternal Connectors System Board ConnectorsMini-Tower Two Desktop One Small Form Factor Audio Back Panel Mini-Tower/DesktopControls and Lights Physical Height Width Depth Weight EnvironmentalPage Contacting Dell Visit support.dell.com