Dell 2100/180, 2100/200 Install the Scsi drives in the hard-disk drive cage, Test the Scsi drives

Page 116

9.Install the SCSI drive(s) in the hard-disk drive cage.

Slide the drive into the cage, align the drive’s mount- ing-screw holes with the holes in the drive cage, and secure the drive with four screws (Figure 9-5).

NOTE: The screws provided with drives purchased from Dell include special screws with shallow heads. Screws with larger heads may make it difficult to reinstall the hard-disk drive cage.

hard-disk drive cage mounting tabs (2)

hard-disk drive mounting screws (4)

Figure 9-5. Installing a Hard-Disk Drive in the Drive Cage

10.Reinstall the hard-disk drive cage in the chassis (Figure 9-4).

Align the tabs on the drive cage with the rails on the bottom of the upper drive cage, and then slide the drive cage into position. Secure the drive cage with the four mounting screws that you removed earlier.

11.Attach a direct current (DC) power cable connec- tor to the power input connector on each SCSI drive.

See “DC Power Cables” in Chapter 8 for instructions on which DC power cable to use.

12.Attach the SCSI cable to each SCSI drive.

For general cabling guidelines, see “SCSI Cable” found earlier in this chapter.

For each drive, firmly press one of the cable’s con- nectors onto the 68-pin connector on the back of the drive.

Match the colored strip on the SCSI cable to the pin-1 side of the connector on the drive. (The con- nectors are shaped so that they cannot be inserted the wrong way.)

13.Attach the SCSI cable to the appropriate connec- tor on the SCSI controller card or the built-in SCSI controller port (SCSI).

If you are using the built-in SCSI controller, its con- nector (SCSI) is near the top of the system board. For any other SCSI controller card, see the docu- mentation that came with the controller card.

Align the colored edge of the cable with the pin-1 end of the SCSI connector on the system board or SCSI controller card. The cable and connector are also aligned by a key on the cable end and a notch in the connector shroud. Press the connectors together firmly.

14.Replace the computer cover and front bezel accord- ing to the instructions in “Replacing the Computer Cover” and “Replacing the Front Bezel” in Chap- ter 6.

15.Then reconnect the computer and peripherals to their power sources, and turn them on.

16.Install any required SCSI device drivers.

For information on installing the appropriate drivers and preparing your SCSI hard-disk drive for use, see Chapter 3, “Installing and Configuring SCSI Drivers.”

17.Test the SCSI drives.

Run the SCSI Devices Test Group of the diskette- based diagnostics. See the chapter titled “Running the Diskette-Based Diagnostics” in your Diagnostics and Troubleshooting Guide for information on running the diagnostics.

9-116 Dell PowerEdge 2100/180 and 2100/200 Systems User’s Guide

Image 116
Contents USER’S Guide Page Ergonomic Computing Habits Safety InstructionsWhen Using Your Computer System Page When Working Inside Your Computer Protecting Against Electrostatic DischargePage Preface About This GuideNotational Conventions Warranty and Return Policy InformationOther Documents You May Need Typographical Conventions Example autoexec.bat and c\windowsPage System Features IntroductionDell PowerEdge 2100/180 and 2100/200 Systems User’s Guide Supported Operating Systems Connecting External DevicesFront Panel Preventing Unauthorized Access Inside the Computer Getting HelpCD Main Menu Using the Dell Server Assistant CDBooting the CD Configure the System Choose LanguageRun System Utilities Use Online ManualsCreate Operating System Support Diskettes Create Windows NT Server 3.51 DiskettesCreate NetWare 4.x Diskettes Create NetWare 3.12 DiskettesInstalling Video Drivers for Windows NT Video DriversAsset Tag Utility Restart Windows NTAssigning and Deleting an Asset Tag Number Using the Asset Tag UtilityAsset Tag Command-Line Options Dell PowerEdge 2100/180 and 2100/200 Systems User’s Guide SCSISelect Utility Installing and Configuring Scsi DriversScsi Select Default Settings Default Scsi Controller Settings Basic Host Adapter SettingsBoot Device Settings Scsi Device Settings Advanced Host Adapter SettingsStarting the SCSISelect Utility Installation for Microsoft Win- dows NT Using SCSISelect MenusUsing the Scsi Disk Utilities Installation OverviewInstalling Windows NT 3.51 and the Driver Performing a Windows NT 3.51 InstallationPerforming a Windows NT 4.0 Installation Using Windows NT to Install or Update the DriverInstalling or Updating the Driver With Win- dows NT When you see the following message, click OK to exit Removing a Host AdapterSwapping a Host Adapter Restart your computerInstallation for Novell NetWare Troubleshooting for Windows NTInstalling EZ-SCSI Calculating the Slot NumberInstalling NetWare and the Driver Performing a NetWare 4.x InstallationPerforming a NetWare 3.12 Installation Load pathname aic7870.dsk options slot=xLoad Command Line Options Using NetWare to Install or Update the DriverUsing the load Command Line Options Devenable= Lunenable=Tagdisable IocombineSample load Command Using Scsi DevicesBit Mask Options Load pathname aic7870 options slot=xBooting From a Scsi Device Using Removable MediaFiles Necessary to Set Up Booting From a Scsi Device Formatting MediaRead After Write Verify Options Using NetWare-Tested and -Approved DrivesDrive Status Items Optimizing Performance Using the NetWare Tape Backup UtilitySetting Up a CD-ROM Drive With Net- Ware 3.12 or Troubleshooting for NetWare Non-Host-Adapter SpecificHost-Adapter Specific OffDell PowerEdge 2100/180 and 2100/200 Systems User’s Guide Using the System Setup Program System Setup ScreensConfiguration Options and System Data Title BoxKey Functions System Setup KeysHelp Entering the System Setup Program Main Menu of the System Setup ProgramMain Menu Categories Boot Options Submenu Categories Boot Options SubmenuService Tag Num LockSpeaker MicroprocessorAdvanced Menu of the System Setup Program Advanced Menu CategoriesParallel Mode Serial PortParallel Port Diskette ControllerSecurity Menu of the System Setup Program Security Menu CategoriesSupervisor Password Is User Password IsSet Supervisor Password Set User PasswordExit Menu Categories Virus Check ReminderUsing the Password Features Using Your Supervisor Password to Secure Your System Operating With a Supervisor Password EnabledDeleting or Changing an Existing Super- visor Password Using the User Password FeatureAssigning a User Password Using Your User Password to Secure Your SystemDeleting or Changing an Existing User Password Disabling a Forgotten PasswordPassword Options Password OptionsResponding to Error Messages Dell PowerEdge 2100/180 and 2100/200 Systems User’s Guide System Board Options Using the Eisa Configuration UtilityConfiguring EISA, ISA, and PCI Expansion Cards How to Run the Eisa Configura- tion Utility When to Run the Eisa Configu- ration UtilityUsing Online Instructions Starting the Eisa Configuration UtilityMaking Selections in the Eisa Configu- ration Utility Learn About Configuring Your Computer Configure ComputerImportant Eisa Configuration Information Main MenuAdd or Remove Boards Adding an Expansion CardView or Edit Details Repositioning an Expansion CardDisplay the list of system board options as follows Dell PowerEdge 2100/180 and 2100/200 Systems User’s Guide Eisa System Board Options Screen Example Maintain System Configuration Diskette Advanced MenuSet Date and Set Time Exit From This UtilitySet Verification Mode Menu Resolving Resource ConflictsView Additional System Information Menu Maintain SCI Files MenuModeling Mode System Board Options ScreenHow Password Security Works Assigning or Changing a Supervisor Password Deleting an Existing Supervisor PasswordSelect the Supervisor Password category Type your new supervisor passwordAssigning or Changing a User Password Deleting an Existing User PasswordSelect the User Password category Type your new user passwordDisabling a Forgotten Password Before You Begin Safety First-For You and Your ComputerWorking Inside Your Computer Replacing the Computer Cover System OrientationRemoving the Computer Cover Removing the Front Bezel Replacing the Front BezelUnpacking Your Hardware Option Inside Your ComputerWorking Inside Your Computer Inside the Chassis-Front/Right Side View Inside the Chassis-Back/Left Side View Removing and Replacing the System Board Assembly Removing the System Board AssemblyPartially remove the system board assembly from the chassis Disconnect the following cables from the system boardReconnect the cables to the system board Replacing the System Board AssemblyInstall the system board assembly in the chassis Dell PowerEdge 2100/180 and 2100/200 Systems User’s Guide Installing System Board Options System Board FeaturesExpansion Cards Expansion Card ExamplesInstalling an Expansion Card Expansion SlotsInstalling an Expansion Card Removing an Expansion CardAdding Memory DIMMs and Dimm SocketsMemory Upgrade Kits Dimm Installation GuidelinesInstalling System Board Options Performing a Memory Upgrade Sample Dimm ConfigurationsInstalling a Dimm Installing a Microprocessor Upgrade Removing a DimmUnpack the new microprocessor Remove the heat sinkRemove the microprocessor chip from the socket Install the microprocessor chip in the socket Fig- ure 10. Pin-1 Identification12. Installing the Heat Sink Replace the microprocessor securing clipReplacing the System Battery Remove the old batteryInstall the new battery with the side labeled + fac- ing up Dell PowerEdge 2100/180 and 2100/200 Systems User’s Guide Jumpers Installing Drives in the External BaysConfiguring a Drive External Drive Bay Hardware Removing Metal Inserts Removing and Replacing Front- Panel InsertsRemoving and Replacing Plastic Inserts Connecting the Drive Removing a Metal InsertInstalling Drives in the External Bays DC Power CablesPrepare the drive for installation Diskette Drive Interface CableInstalling Scsi Drives in the External Bays Verify correct operation of your systemConfigure the controller card if necessary 10 -Pin to 50-Pin Adapter11. Connecting an Optional Scsi Controller Card Dell PowerEdge 2100/180 and 2100/200 Systems User’s Guide Scsi ID Numbers Installing Drives in the Internal BaysScsi Configuration Guidelines Device Termination Scsi Termination Jumper LocationsConfiguring the Boot Device Scsi CableScsi Cable for a PowerEdge 2100 System Installing Scsi Hard-Disk Drives in the Internal Bays Unpack each Scsi drive, and prepare it for installationInstall the Scsi drives in the hard-disk drive cage Reinstall the hard-disk drive cage in the chassis FigureAttach the Scsi cable to each Scsi drive Test the Scsi drivesTechnical Specifications Table A-1. Technical SpecificationsDrives Power Dell PowerEdge 2100/180 and 2100/200 Systems User’s Guide Hardware Configuration Features Jumpers-A General ExplanationFigure B-1. System Board Jumpers Cardbios VGA Eisa Table B-1. System Board JumpersConnectors and Sockets Table B-2. Connectors and Sockets on the System BoardPorts and Connectors Serial and Parallel PortsSerial Port Connectors Figure B-3. Pin Numbers for the Serial Port ConnectorsTable B-3. Pin Assignments for the Serial Port Connectors Parallel Port ConnectorKeyboard and Mouse Connectors Keyboard Connector Mouse ConnectorRED Dell PowerEdge 2100/180 and 2100/200 Systems User’s Guide Scheduling Backups Backup DevicesRecovering Data Maintaining the SystemCleaning System Components Recommended Tools and AccessoriesCleaning the Computer, Monitor, and Keyboard Exteriors Cleaning DrivesTemperature Environmental FactorsHumidity AltitudeElectromagnetic and Radio Frequency Interference Dust and ParticlesCorrosion Shock and Vibration Power Source InterruptionsMagnetism Power Protection Devices Uninterruptible Power SupplySurge Protectors Line ConditionersRegulatory Notices FCC Notices U.S. OnlyClass a Class BCE Notice IC Notice Canada OnlyEN 55022 Compliance Czech Republic Only Class 2 Notice Vcci Notices Japan OnlyClass 1 Notice Polish Center for Testing and Certification Notice Korean Regulatory NoticeWymagania Polskiego Centrum Badañ i Certyfikacji Pozosta³e instrukcje bez pieczeñstwaRegulatory Notices D-141 Dell PowerEdge 2100/180 and 2100/200 Systems User’s Guide Coverage During Year One Limited Three-Year Warranty U.S. OnlyWarranties and Return Policy General Limited Three-Year Warranty Canada OnlyCoverage During Years Two and Three Warranties and Return Policy E-145 Total Satisfaction Return Policy U.S. and Canada Only Table F-1. Technical Specifications Drives Technical Specifications F-149 Dell PowerEdge 2100/180 and 2100/200 Systems User’s Guide Glossary Bios BBSBTU BZTCcft CD-ROMCGA CmosDimm DINDIP DMADTE ECCECP EDOFAT FCCGUI HMAIPX IRQISA ITELUN MBRMDA MGANLM NMINtfs NvramPost PqfpPRN PVCROM RTCScsi SdmsTFT TSRUMB UPSVGA VDSVesa Vlsi VramXMM XMS
Related manuals
Manual 73 pages 16.31 Kb

2100/180, 2100/200 specifications

The Dell 2100/200 and Dell 2100/180 are innovative offerings from Dell that cater to the demands of a variety of users, ranging from small businesses to larger enterprises. Both models are designed to deliver high performance and reliability, making them indispensable tools in the modern computing environment.

The Dell 2100/200 features an impressive Intel processor that ensures fast and efficient performance, making it suitable for multitasking and handling complex applications. Coupled with a generous RAM configuration, this model can easily manage demanding workloads, resulting in smoother performance and faster processing times. In contrast, the Dell 2100/180, while slightly less powerful, still maintains robust performance levels that are well-suited for general productivity tasks and everyday use.

Both models come equipped with ample storage options, featuring hard disk drives that provide significant space for data and application storage. Users can choose between traditional HDDs and solid-state drives (SSDs), allowing them to prioritize speed and performance based on their specific needs. The flexibility in storage options ensures that users can customize their systems according to their requirements, enhancing the overall user experience.

Connectivity is another area where the Dell 2100 series excels. Both models come with a range of ports including USB, HDMI, and Ethernet, allowing for seamless connectivity with various peripherals and networks. This versatility makes the machines ideal for environments where multiple devices need to be connected simultaneously, whether for presentations, data transfer, or internet access.

In terms of energy efficiency, both the Dell 2100/200 and Dell 2100/180 incorporate advanced cooling technologies that minimize energy consumption while maximizing performance. This not only helps reduce operational costs but also contributes to a more sustainable computing environment.

The design of these models is another distinguishing feature. With a compact form factor, they fit easily into office spaces while maintaining a professional appearance. Their durable build quality ensures longevity, making them a worthwhile investment for businesses.

Overall, the Dell 2100/200 and Dell 2100/180 serve as powerful and reliable machines that combine advanced technologies and user-centric designs. Whether for business or personal use, these models provide a solid foundation for effective computing, ensuring that users can achieve their goals efficiently and effectively.