Dell 2100/200, 2100/180 manual Installing or Updating the Driver With Win- dows NT

Page 27

Installing or Updating the Driver With Win- dows NT 3.51

Follow these instructions only if Windows NT 3.51 is already installed:

1.Select and start the Windows NT Setup program. (Its icon is usually found in the Main program group.) There is a brief pause while Windows NT Setup scans your hardware configuration.

2.Select the Options pull-down menu, and then select Add/Remove SCSI Adapters. The SCSI Adapter setup program displays a list of all host adapters currently installed.

If you are installing the driver for the first time, skip to step 5.

If you are updating the driver, continue to step 3.

3.Before you can update the driver, you must first remove the existing driver. Select the host adapter you want to remove (for example, the Adaptec AIC-78xxSCSI controller), and click Remove. When the Windows NT Setup program asks you for confirmation, click OK.

Because SCSI device drivers are loaded during sys- tem start-up and because they may be needed to load Windows NT itself, the following warning message may appear:

Removing SCSI Adapters may prevent Windows NT from starting correctly.

4.When you are sure you are removing the correct host adapter driver, click OK.

5.Click Add to add another host adapter type to the list. A list of additional SCSI adapters appears.

6.Expand the list of additional SCSI adapters; select Other and press <Enter>.

7.Insert the Windows NT 3.51 driver diskette you created into drive A, enter the following path to the installation files, and then click OK.

a:\scsi

8.The screen displays the adapter drivers sup- ported on the diskette. The Adaptec AHA-2940UW/AIC-78xx(PCI) NT 3.51 driver is highlighted by default; click OK. The driver is added to the list of SCSI adapters.

9.Select Adaptec AHA-2940UW/AIC-78xx (PCI) NT 3.51 from the list of SCSI adapters, and click Install.

At this point, Windows NT Setup checks to see if the specified driver (aic78xx.sys) has already been cop- ied to the hard-disk drive.

10.If the following message appears, click New to replace the existing driver and go to step 12.

The driver(s) for this SCSI Adapter are already on the system. Do you want to use the currently installed driver(s) or install new one(s).

If the following message appears, continue to step 11:

Please <Enter> the full path to the Windows NT SCSI Adapter files.

11.Change the path to the directory with the desired device driver (for example, a:\scsi); then click

Continue.

The device driver is copied to your hard-disk drive and the Windows NT configuration is updated so that the new device driver loads when Windows NT reboots.

12.When the installation is complete, Windows NT Setup again displays a list of currently installed host adapter types. Verify that the new host adapter appears on the list; the string should look similar to:

Adaptec AHA-2940UW/AIC-78xx (PCI) NT v3.5x

13.If you want to add other host adapters (that are not part of the Adaptec 78xx series), do so at this time by repeating steps 6 through 8 for each addi- tional adapter, inserting the appropriate diskette provided by the hardware manufacturer. Because all Adaptec 78xx series host adapters use the same driver, you configure all Adaptec host adapters at the same time.

14.Click Close to exit the SCSI adapters portion of Windows NT Setup, and then close the program.

Installing and Configuring SCSI Drivers

3-27

Image 27
Contents USER’S Guide Page Safety Instructions When Using Your Computer SystemErgonomic Computing Habits Page Protecting Against Electrostatic Discharge When Working Inside Your ComputerPage About This Guide PrefaceWarranty and Return Policy Information Other Documents You May NeedNotational Conventions Example autoexec.bat and c\windows Typographical ConventionsPage Introduction System FeaturesDell PowerEdge 2100/180 and 2100/200 Systems User’s Guide Connecting External Devices Front PanelSupported Operating Systems Getting Help Preventing Unauthorized Access Inside the ComputerUsing the Dell Server Assistant CD Booting the CDCD Main Menu Use Online Manuals Configure the SystemChoose Language Run System UtilitiesCreate NetWare 3.12 Diskettes Create Operating System Support DiskettesCreate Windows NT Server 3.51 Diskettes Create NetWare 4.x DiskettesRestart Windows NT Installing Video Drivers for Windows NTVideo Drivers Asset Tag UtilityUsing the Asset Tag Utility Asset Tag Command-Line OptionsAssigning and Deleting an Asset Tag Number Dell PowerEdge 2100/180 and 2100/200 Systems User’s Guide Installing and Configuring Scsi Drivers Scsi Select Default SettingsSCSISelect Utility Basic Host Adapter Settings Boot Device SettingsDefault Scsi Controller Settings Advanced Host Adapter Settings Scsi Device SettingsStarting the SCSISelect Utility Installation Overview Installation for Microsoft Win- dows NTUsing SCSISelect Menus Using the Scsi Disk UtilitiesUsing Windows NT to Install or Update the Driver Installing Windows NT 3.51 and the DriverPerforming a Windows NT 3.51 Installation Performing a Windows NT 4.0 InstallationInstalling or Updating the Driver With Win- dows NT Restart your computer When you see the following message, click OK to exitRemoving a Host Adapter Swapping a Host AdapterTroubleshooting for Windows NT Installation for Novell NetWareCalculating the Slot Number Installing EZ-SCSIPerforming a NetWare 4.x Installation Installing NetWare and the DriverLoad pathname aic7870.dsk options slot=x Performing a NetWare 3.12 InstallationUsing NetWare to Install or Update the Driver Using the load Command Line OptionsLoad Command Line Options Iocombine Devenable=Lunenable= TagdisableLoad pathname aic7870 options slot=x Sample load CommandUsing Scsi Devices Bit Mask OptionsFormatting Media Booting From a Scsi DeviceUsing Removable Media Files Necessary to Set Up Booting From a Scsi DeviceUsing NetWare-Tested and -Approved Drives Drive Status ItemsRead After Write Verify Options Using the NetWare Tape Backup Utility Setting Up a CD-ROM Drive With Net- Ware 3.12 orOptimizing Performance Off Troubleshooting for NetWareNon-Host-Adapter Specific Host-Adapter SpecificDell PowerEdge 2100/180 and 2100/200 Systems User’s Guide Title Box Using the System Setup ProgramSystem Setup Screens Configuration Options and System DataSystem Setup Keys HelpKey Functions Main Menu of the System Setup Program Entering the System Setup ProgramMain Menu Categories Boot Options Submenu Boot Options Submenu CategoriesMicroprocessor Service TagNum Lock SpeakerAdvanced Menu Categories Advanced Menu of the System Setup ProgramDiskette Controller Parallel ModeSerial Port Parallel PortSecurity Menu Categories Security Menu of the System Setup ProgramSet User Password Supervisor Password IsUser Password Is Set Supervisor PasswordVirus Check Reminder Exit Menu CategoriesUsing the Password Features Using the User Password Feature Using Your Supervisor Password to Secure Your SystemOperating With a Supervisor Password Enabled Deleting or Changing an Existing Super- visor PasswordUsing Your User Password to Secure Your System Assigning a User PasswordDisabling a Forgotten Password Deleting or Changing an Existing User PasswordPassword Options Password OptionsResponding to Error Messages Dell PowerEdge 2100/180 and 2100/200 Systems User’s Guide Using the Eisa Configuration Utility Configuring EISA, ISA, and PCI Expansion CardsSystem Board Options When to Run the Eisa Configu- ration Utility How to Run the Eisa Configura- tion UtilityStarting the Eisa Configuration Utility Making Selections in the Eisa Configu- ration UtilityUsing Online Instructions Main Menu Learn About Configuring Your ComputerConfigure Computer Important Eisa Configuration InformationAdding an Expansion Card Add or Remove BoardsRepositioning an Expansion Card View or Edit DetailsDisplay the list of system board options as follows Dell PowerEdge 2100/180 and 2100/200 Systems User’s Guide Eisa System Board Options Screen Example Exit From This Utility Maintain System Configuration DisketteAdvanced Menu Set Date and Set TimeMaintain SCI Files Menu Set Verification Mode MenuResolving Resource Conflicts View Additional System Information MenuSystem Board Options Screen Modeling ModeHow Password Security Works Type your new supervisor password Assigning or Changing a Supervisor PasswordDeleting an Existing Supervisor Password Select the Supervisor Password categoryType your new user password Assigning or Changing a User PasswordDeleting an Existing User Password Select the User Password categoryDisabling a Forgotten Password Safety First-For You and Your Computer Working Inside Your ComputerBefore You Begin System Orientation Removing the Computer CoverReplacing the Computer Cover Replacing the Front Bezel Removing the Front BezelInside Your Computer Unpacking Your Hardware OptionWorking Inside Your Computer Inside the Chassis-Front/Right Side View Inside the Chassis-Back/Left Side View Disconnect the following cables from the system board Removing and Replacing the System Board AssemblyRemoving the System Board Assembly Partially remove the system board assembly from the chassisReplacing the System Board Assembly Install the system board assembly in the chassisReconnect the cables to the system board Dell PowerEdge 2100/180 and 2100/200 Systems User’s Guide System Board Features Installing System Board OptionsExpansion Card Examples Expansion CardsExpansion Slots Installing an Expansion CardRemoving an Expansion Card Installing an Expansion CardDIMMs and Dimm Sockets Adding MemoryDimm Installation Guidelines Memory Upgrade KitsInstalling System Board Options Sample Dimm Configurations Performing a Memory UpgradeInstalling a Dimm Removing a Dimm Installing a Microprocessor UpgradeRemove the heat sink Remove the microprocessor chip from the socketUnpack the new microprocessor 10. Pin-1 Identification Install the microprocessor chip in the socket Fig- ureReplace the microprocessor securing clip 12. Installing the Heat SinkRemove the old battery Replacing the System BatteryInstall the new battery with the side labeled + fac- ing up Dell PowerEdge 2100/180 and 2100/200 Systems User’s Guide Installing Drives in the External Bays Configuring a DriveJumpers External Drive Bay Hardware Removing and Replacing Front- Panel Inserts Removing and Replacing Plastic InsertsRemoving Metal Inserts Removing a Metal Insert Connecting the DriveDC Power Cables Installing Drives in the External BaysDiskette Drive Interface Cable Prepare the drive for installationVerify correct operation of your system Installing Scsi Drives in the External Bays10 -Pin to 50-Pin Adapter Configure the controller card if necessary11. Connecting an Optional Scsi Controller Card Dell PowerEdge 2100/180 and 2100/200 Systems User’s Guide Installing Drives in the Internal Bays Scsi Configuration GuidelinesScsi ID Numbers Scsi Termination Jumper Locations Device TerminationScsi Cable Configuring the Boot DeviceScsi Cable for a PowerEdge 2100 System Unpack each Scsi drive, and prepare it for installation Installing Scsi Hard-Disk Drives in the Internal BaysTest the Scsi drives Install the Scsi drives in the hard-disk drive cageReinstall the hard-disk drive cage in the chassis Figure Attach the Scsi cable to each Scsi driveTable A-1. Technical Specifications Technical SpecificationsDrives Power Dell PowerEdge 2100/180 and 2100/200 Systems User’s Guide Jumpers-A General Explanation Hardware Configuration FeaturesFigure B-1. System Board Jumpers Table B-1. System Board Jumpers Cardbios VGA EisaTable B-2. Connectors and Sockets on the System Board Connectors and SocketsSerial and Parallel Ports Ports and ConnectorsFigure B-3. Pin Numbers for the Serial Port Connectors Serial Port ConnectorsParallel Port Connector Keyboard and Mouse ConnectorsTable B-3. Pin Assignments for the Serial Port Connectors Mouse Connector Keyboard ConnectorRED Dell PowerEdge 2100/180 and 2100/200 Systems User’s Guide Maintaining the System Scheduling BackupsBackup Devices Recovering DataCleaning Drives Cleaning System ComponentsRecommended Tools and Accessories Cleaning the Computer, Monitor, and Keyboard ExteriorsAltitude TemperatureEnvironmental Factors HumidityDust and Particles CorrosionElectromagnetic and Radio Frequency Interference Power Source Interruptions MagnetismShock and Vibration Line Conditioners Power Protection DevicesUninterruptible Power Supply Surge ProtectorsClass B Regulatory NoticesFCC Notices U.S. Only Class aIC Notice Canada Only EN 55022 Compliance Czech Republic OnlyCE Notice Vcci Notices Japan Only Class 1 NoticeClass 2 Notice Pozosta³e instrukcje bez pieczeñstwa Polish Center for Testing and Certification NoticeKorean Regulatory Notice Wymagania Polskiego Centrum Badañ i CertyfikacjiRegulatory Notices D-141 Dell PowerEdge 2100/180 and 2100/200 Systems User’s Guide Limited Three-Year Warranty U.S. Only Warranties and Return PolicyCoverage During Year One Limited Three-Year Warranty Canada Only Coverage During Years Two and ThreeGeneral Warranties and Return Policy E-145 Total Satisfaction Return Policy U.S. and Canada Only Table F-1. Technical Specifications Drives Technical Specifications F-149 Dell PowerEdge 2100/180 and 2100/200 Systems User’s Guide Glossary BZT BiosBBS BTUCmos CcftCD-ROM CGADMA DimmDIN DIPEDO DTEECC ECPHMA FATFCC GUIITE IPXIRQ ISAMGA LUNMBR MDANvram NLMNMI NtfsPVC PostPqfp PRNSdms ROMRTC ScsiUPS TFTTSR UMBVDS VesaVGA XMS VlsiVram XMM
Related manuals
Manual 73 pages 16.31 Kb

2100/180, 2100/200 specifications

The Dell 2100/200 and Dell 2100/180 are innovative offerings from Dell that cater to the demands of a variety of users, ranging from small businesses to larger enterprises. Both models are designed to deliver high performance and reliability, making them indispensable tools in the modern computing environment.

The Dell 2100/200 features an impressive Intel processor that ensures fast and efficient performance, making it suitable for multitasking and handling complex applications. Coupled with a generous RAM configuration, this model can easily manage demanding workloads, resulting in smoother performance and faster processing times. In contrast, the Dell 2100/180, while slightly less powerful, still maintains robust performance levels that are well-suited for general productivity tasks and everyday use.

Both models come equipped with ample storage options, featuring hard disk drives that provide significant space for data and application storage. Users can choose between traditional HDDs and solid-state drives (SSDs), allowing them to prioritize speed and performance based on their specific needs. The flexibility in storage options ensures that users can customize their systems according to their requirements, enhancing the overall user experience.

Connectivity is another area where the Dell 2100 series excels. Both models come with a range of ports including USB, HDMI, and Ethernet, allowing for seamless connectivity with various peripherals and networks. This versatility makes the machines ideal for environments where multiple devices need to be connected simultaneously, whether for presentations, data transfer, or internet access.

In terms of energy efficiency, both the Dell 2100/200 and Dell 2100/180 incorporate advanced cooling technologies that minimize energy consumption while maximizing performance. This not only helps reduce operational costs but also contributes to a more sustainable computing environment.

The design of these models is another distinguishing feature. With a compact form factor, they fit easily into office spaces while maintaining a professional appearance. Their durable build quality ensures longevity, making them a worthwhile investment for businesses.

Overall, the Dell 2100/200 and Dell 2100/180 serve as powerful and reliable machines that combine advanced technologies and user-centric designs. Whether for business or personal use, these models provide a solid foundation for effective computing, ensuring that users can achieve their goals efficiently and effectively.