When a member of the RAID 1 array is broken, the computer automatically rebuilds the mirror array using the spare hard drive as the broken member’s replacement.
To Mark a Drive as a Spare Hard Drive:
1In Windows XP, click Start→ All Programs→ Intel®Matrix Storage Manager→ Intel Matrix Storage Console to launch the Intel® Storage Utility.
In Windows Vista, click Start → Programs→ Intel®Matrix Storage Manager→ Intel Matrix Storage Manager to launch the Intel® Storage Utility.
2
3Click Mark as Spare.
To Remove Spare Marking From a Spare Hard Drive:
1
2Click Reset Hard Drive to
Rebuilding a Degraded RAID 1 Volume
If your computer does not have a spare hard drive, and the computer has reported a degraded RAID 1 volume, you can manually rebuild the computer’s redundancy mirror to a new hard drive by performing the following steps:
1In Windows XP, click Start→ All Programs→ Intel®Matrix Storage Manager→ Intel Matrix Storage Console to launch the Intel® Storage Utility.
In Windows Vista, click Start → Programs→ Intel®Matrix Storage Manager→ Intel Matrix Storage Manager to launch the Intel® Storage Utility.
2
NOTE: You can use your computer while the computer is rebuilding the RAID 1 volume.
48