Troubleshooting
Symptom | Probable cause | Action | |
| The batteries are not loaded properly. | Verify that the batteries’ polarities = | |
| and | ||
|
| ||
Nothing appears on | Battery power is getting low. | Charge the batteries or replace with | |
the display | new batteries (☞ P.15, P.17). | ||
| |||
| The power is off. | Turn the power on (☞ P.20). | |
|
|
| |
| Battery power is getting low. | Charge the batteries or replace with | |
| new batteries (☞ P.15, P.17). | ||
|
| ||
Won’t start | The power is off. | Turn the power on (☞ P.20). | |
|
|
| |
| The recorder is in HOLD mode. | Release the recorder from HOLD | |
| (☞ P.21). | ||
|
| ||
| Low remaining memory. | Erase unnecessary files (☞ P.45). | |
Unable to record |
|
| |
The maximum number of files has | Change to any other folder | ||
| |||
| been reached. | (☞ P.27 to P.29). | |
Unable to record | An external microphone supported by | Set | |
through an external | external microphone supported by | ||
microphone | in Power] is set to [Off]. | ||
| The earphone is connected. | Unplug the earphones to use the | |
No playback sound | internal speaker. | ||
| |||
heard | The volume level is set to [00]. | Adjust the volume level (☞ P.37). | |
| |||
|
|
| |
| The recording level has not been | Adjust the recording level and then try | |
| adjusted. | recording once more (☞ P.51). | |
Recording level too | The microphone sensitivity is too low. | Set [Mic Sense] to [High] or [Middle] | |
(☞ P.50). | |||
low |
| ||
This could potentially be because | Adjust the output level for the | ||
| |||
| the output level for the connected | ||
| connected devices. | ||
| external devices are too low. | ||
|
| ||
| The recording level has not been | Adjust the recording level and then try | |
| adjusted. | recording once more (☞ P.51). | |
Recording level too | This could potentially be because | If you cannot record clearly even | |
high | |||
the recording level and output level | after adjusting the recording level, | ||
| for connected external devices are | then adjust the output level for the | |
| too high. | connected devices (☞ P.51). |