5. Replace the cover, inserting the lower tabs first.

When BATT.Lo flashes and the scanner beeps every 15 seconds, replace all four batteries.

Warning: Always dispose of old batteries promptly and properly. Do not bury or burn them.

Using Rechargeable Batteries

You can also use four rechargeable batteries. Before you use Ni-Cd or Ni-MH batteries, you must charge them.

The scanner has a built-in circuit that lets you recharge Ni-Cd and Ni-MH batteries while they are in the scanner.

To charge the batteries, set ALKALINE JACK NI-CDto NI-CD, install the batteries in the scanner, and connect an external AC or DC adapter to the scanner’s POWER jack (see “Using AC Power” on Page 13 or “Using Vehi- cle Battery Power” on Page 14).

Warning: Do not connect either adapter to the scanner if non-rechargeable batteries (such as alkaline batteries) are installed in the scanner and ALKALINE JACK NI- CD is set to NI-CD,or if you are unsure of the switch’s po- sition. Non-rechargeable batteries will get hot and can even explode if you try to recharge them.

Before you use Ni-Cd or Ni-MH batteries for the first time, charge them at least 24 hours to bring them to a full charge.

Discharged batteries take about 10 to 18 hours to fully recharge. If you use the scanner while the batteries are charging, charging takes longer.

Notes:

Ni-Cd batteries last longer and deliver more power if you occasionally let them fully discharge. To do this, simply use the scanner until it beeps every 15 sec- onds and BATT.Lo flashes.

To prevent damage to Ni-Cd batteries, never charge them in an area where the temperature is above 113°F (40°C) or below 40°F (4°C).

12Preparation

Image 12
Contents PRO-94 1000-Channel Handheld Trunking Scanner Contents Special Features Trunking OperationTroubleshooting Care and Maintenance SpecificationsGeneral Guide to Scanning Features Features Features FCC Notice Frequency Step Range MHz KHz TransmissionScanning Legally Using Internal Batteries Using Non-Rechargeable BatteriesPreparation Preparation11 Using Rechargeable Batteries 12PreparationUsing AC Power Using Vehicle Battery Power Connecting the Antenna Connecting AN EARPHONE/ HeadphoneConnecting an Optional Antenna Traffic Safety Listening SafelyConnecting AN Extension Speaker Attaching the Belt ClipAbout Your Scanner Look AT the Keypad Key FunctionsLook AT the Display NumberKeys About Your Scanner Service Banks Understanding BanksChannel Storage Banks Monitor Memories Turning on the Scanner Setting Squelch OperationStoring Known Frequencies Into Channels Searching for and Temporarily Storing Active Frequencies Limit Search Direct SearchService Bank Search Search Skip Memory Listening to the Monitor Memories Moving a Frequency from a Monitor Memory to a ChannelScanning the Stored Channels Manually Selecting a ChannelSpecial Features DelayTurning CHANNEL-STORAGE Banks on and OFF Locking OUT Channels PriorityUsing the Keylock Using the Display Backlight Using the Auto Backlight DisplayChanging Search Speeds Turning the Keytone OFF/ONTurning the Battery Save Function OFF/ON Skipping Data SignalsReceiving NWR-SAME Weather Alert Signals Turning On the Same Weather Alert Feature Same Signal Detection UpdatingNWR-SAME Alert Tone Test NWR-SAME Code Detection TestsTrunking Operation Types of Trunking SystemsSetting the Scanner to the Trunking Mode Simultaneous TrunkingSetting Squelch for the Trunking Mode Storing Trunked FrequenciesYou See Trunk System Motorola Type II, 900 MHz frequencies Motorola Type II, VHF frequenciesMotorola Type II, UHF frequencies Searching a Trunked Bank Turning a Trunked Bank On or OffSkipping a Trunked Bank Turning the Status Bit Ignore S-Bit On or OffIdentifying a Trunked Frequency Selecting the Edacs Talk Group ID FormatEdacs Talk Group ID Range Search Press 0 1 . SRC LimitUsing Hold to Monitor an Active Talk Group ID Locking Out Talk Group IDsUsing Trunk Scanning Scan Delay Unlocking a Single Talk Group IDUnlocking All Talk Group IDs Channel Activity Bars Monitoring Talk Group IDsUsing Talk Group ID Lists Manually Storing Talk Group IDs in Talk Group ID ListsEntering Edacs Partial Talk Groups Moving Talk Group IDs to Talk Group ID ListsYou Press To Scan 01 . EScanning the Talk Group ID Lists Deleting a Stored Talk Group ID ListPriority Talk Group ID Scanning Scanning Type I and Hybrid Trunked Systems E1P1 E1P2 E1P3 E1P4 E1P5 E1P6E1P7 E1P8 E1P9 E1P10 E1P11 E1P12E1P13 E1P14 E1P15 Selecting a Preset Fleet Map E1P16Press Data ALT Programming a Fleet Map Prog then TrunkSize Code Block Programming the Base Offset Frequencies Programming a Hybrid System Turning On/Off the Motorola Disconnect Tone Detect FunctionGeneral Guide to Scanning Guide to FrequenciesNational Weather Frequencies Birdie FrequenciesGuide to the Action Bands Typical Band UsagePrimary Usage VHF BandAbbreviations Services Band AllocationUHF Band VHF Low Band- 29-50 MHz in 5 kHz steps Amateur Band 50-54 MHzAircraft Band- 108-137 MHz Amateur Band 144-148 MHzVHF High Band 148-174 MHz Government Band 406-420 MHz 406.125-419.975Cm Amateur Band 420-450 MHz Public Safety Band Locally Assigned Low Band 450-470 MHzConventional Systems Band Locally Assigned 856.0125-860.9875Frequency Conversion Troubleshooting Problem Possible Cause RemedySquelch is not BATT. Lo Troubleshooting67 Resetting the Scanner Care and Maintenance Specifications Search SpeedSquelched 70 mA Limited Ninety-Day Warranty

PRO-94 specifications

The Radio Shack PRO-94 is a versatile and feature-rich handheld scanner that has garnered attention from both amateur radio enthusiasts and professional users alike. Renowned for its accessibility and performance, the PRO-94 serves as an ideal device for those looking to stay connected with various radio frequencies.

One of the main features of the PRO-94 is its ability to receive a wide range of frequencies. The scanner covers VHF low and high bands, UHF, and even the 800 MHz frequency range, allowing users to pick up signals from local police, fire departments, amateur radio operators, and more. This broad frequency range ensures that users can monitor diverse communications and stay informed about local events.

The scanner is equipped with an advanced trunk-tracking technology that allows it to follow trunked radio systems. This is particularly useful for monitoring state and local emergency services, as many of these organizations have migrated to trunked systems to maximize channel efficiency. The PRO-94 simplifies this process by automatically scanning through the trunked frequencies, making it easy for users to catch important dispatches without manual adjustments.

Another standout characteristic of the PRO-94 is its 200 memory channels. Users can program these channels to store specific frequencies, making quick access seamless. The scanner also supports multiple banks, allowing for organized grouping of channels, which is advantageous for users who monitor different types of services or agencies.

With its user-friendly interface, the PRO-94 includes an LCD display that shows relevant information, such as the frequency being received or the bank and channel currently in use. The keypad is designed for efficient navigation, making it straightforward to enter frequency modes and access programmed channels easily. Additionally, the scanner features priority channels, which allow users to monitor certain frequencies continuously, ensuring they do not miss critical communications.

The PRO-94 runs on AA batteries, providing convenience in terms of power supply. Its compact size and lightweight design ensure portability, enabling users to take it on the go, whether on a hiking trip or during community events.

In summary, the Radio Shack PRO-94 stands out as a robust and user-friendly handheld scanner. Its diverse frequency reception, trunk-tracking technology, extensive memory capabilities, and portable design make it a compelling choice for anyone keen on monitoring radio communications.