Radio Shack PRO-97 manual Scanning the channels, Turning channel-storage banks off and on

Page 52

Beyond the Basics

due to their high transmitter output power. You can press L/OUT when the Signal Stalker II stops on these undesired transmissions to prevent the Signal Stalker II from stopping on them in future sweeps, however, the Signal Stalker II will still see their RF signal energy when sweeping through the 1 MHz segment. This will cause the Signal Stalker II to execute another fine step search of the 1 MHz segment. Of course, if you have locked out the undesired transmissions, the Signal Stalker II will not stop on them again, however, the overall sweep performance of the Signal Stalker II will be impacted.

Signal Stalker II features a special lockout mode that causes the scanner to skip a 1 MHz segment if five or more lockouts exist in that 1 MHz segment. To activate this mode, press FUNC e while in the Signal Stalker II mode. If a 1 MHz segment contains 5 or more lockouts it will be skipped entirely while Signal Stalker II is sweeping. Use FUNC L/O to review or clear locked Signal Stalker II frequencies.

To clear a locked-out frequency, select that frequency, then press CL.

scanning the channels

To begin scanning channels or to start scanning again after monitoring a specific channel, press SCAN.

Notes

You must store frequencies into channels before the

scanner can scan them. The scanner does not scan

 

 

through empty channels.

To change the scanning direction, press e or d.

The scanner scans through all channels (except those you have locked out) in the active banks (see “Turning Channel- Storage Banks Off and On”and “Locking Out Channels or Frequencies”).

turning channel-storage banks off and on

To turn off banks while scanning, press the bank’s number

52

Image 52
Contents PRO-97 1,000 Channel Triple Trunking Hand Held Scanner Contents Contents finding and storing active frequencies Trunking Glossary FAQs Frequently Asked Questions Warranty CareSpecifications FCC wants you to knowYour scanner’s controls ENT completes the entry of frequencies and text TUV enters an 8, or inputs characters T, U, or Basics OFF VOL/SQ turn the scanner on or off and adjust the squelch Power sources Using batteriesNever install non-rechargeable batteries Charging rechargeable batteries Using AC power Basics Using vehicle battery power Connecting an earphone/headphonesTraffic safety Connecting an extension speakerListening safely Basics Connecting the supplied antenna Connecting an optional external antennaBasics Using the belt clip Transferring data to or from another scanner orQuick start AM modeUnderstanding your scanner’s modes Ctcss CT mode FM modeDCS DC mode Motorola mode Basics Edacs mode LTR mode Open and closed modes Basics Setting up your scanner Turning on the scanner and setting squelchBasics Storing known frequencies into channels Beyond the Basics Ctcss and DCS Beyond the Basics Storing trunking frequencies into channels DCS Code TableStoring text tags Assigning a text tag to a channelAssigning a text tag to a group ID Assigning a text tag to a bankText input chart finding and storing active frequencies Searching a preprogrammed frequency rangeBand charts Search bank SR0 marine bandBeyond the Basics Search bank SR1 CB band Search bank SR2 FRS/GMRS/MURS bandSearch bank SR3 police/fire band Search bank SR4 aircraft Search bank SR5 amateur band Searching active frequencies in a rangeSearch bank SR6 programmable limit search Beyond the Basics Beyond the Basics Manually tuning a frequency Listening to the weather bandSame standby mode Listening to a weather channelWX Alert and beep tone confirmation Beyond the Basics Skywarn Using frequency copyCopying a frequency into a specified channel Copying a frequency into an empty channel within a bank Signal Stalker Copying a frequency into the priority channelUsing Signal Stalker Using Signal Stalker II with lockoutScanning the channels Turning channel-storage banks off and onUsing Ctcss and DCS Monitoring a single channel/power save circuitDeleting frequencies from channels Deleting all frequencies in a channel bankLocking out channels or frequencies Using delayLocking out channels Locking out frequencies Reviewing locked-out channelsReviewing locked-out frequencies Clearing a locked-out frequency PriorityClearing all locked-out frequencies in a search bank Beyond the Basics Changing the receive mode Using the attenuator Using the display/key backlight Turning the key tone on and offWhile Multi-System Trunking Scanner appears, press Beyond the Basics Using the keylock Changing the display contrastBeyond the Basics Cloning the programmed data Receives data from another scanner other than a PRO-97Trunking How trunking worksTo listen to the transmission, the mode Beyond the Basics Setting squelch for trunking mode Programming trunking frequenciesBeyond the Basics Programming Motorola trunking systems UHF-Lo Beyond the Basics Programming Motorola trunking systems 800 MHz Programming fleet mapsBlock Size Code S10 S11 S12 Talk group IDs Storing talk group IDsBeyond the Basics Beyond the Basics Talk group ID hold Turning an ID sub-bank on or offDelay function in ID indication mode Locking out talk group IDsClearing talk group IDs Reviewing locked-out talk group IDsClearing all talk group IDs in a single bank Changing the open/closed mode Care Service and repairBirdie frequencies Specifications Selectivity 25 27.995 MHz at AM mode ±5 kHz 9V DC Beyond the Basics Initializing your scanner FCC wants you to know Scanning legallyGlossary FAQs Frequently Asked Questions Scanner is not working at all. What’s wrong?RadioShack Corporation