1.Press PGM.
2.Press TRUNK to enter a talk group ID memory mode.
3.Select a talk group ID bank using FUNC, or .
4.Press FUNC then 3. Confirm list clear ?1=YES Press other key for NO. appears.
5.Press 1 to clear the all talk group IDs within a bank.
Please Wait then List Cleared appears.
Note: To cancel the deletion, press any key except 1. The scanner returns to the talk group ID memory mode.
OPEN AND CLOSED MODES
When set to the open mode, the scanner only uses the ID list to look up ID text tags and stops on any ID code.
When set to the closed mode, the scanner stops only on signals that have an ID code which is found in the ID list for the bank.
Note: When you select a channel manually, any trans- mission opens squelch, regardless of the current mode.
Closed Mode
The open or closed mode is set in each channel storage bank. + or – appears under the channel storage bank’s number while scanning. Or, the status display shows the OPEN/CLOSED mode at the top line while the scanner is in manual mode or receiving a signal during scanning.