BATTERY PACK

In order to charge the Battery Pack, there is no need to use a cradle. It can be re-charged when disconnected from the scanner with the Voyager RF 5V, 1.5A Wall Power Supply.

The Battery Pack can’t be recharged while inserted into the Voyager. Therefore it is recommended that two battery packs are used. One can be in use with the scanner while the other one is being recharged.

Once the Voyager RF gives a “Low Battery” warning, the user should remove the Battery Pack from Voyager by pressing the two side clips and pulling the pack vertically from the scanner.

Once removed, the user can see a socket to insert the jack of the 5V, 1.5 A Power Supply. See figure: Batt1

Figure: Batt1

There is an LED which indicates the status of the charge as Table 1.0 shows:

CHARGE STATUS

RED

GREEN

Charging

ON

OFF

Done

OFF

ON

FAULT

Flashing (1 sec.)

OFF

No Battery

OFF

OFF

 

Table 1.0

 

It takes a charge of around 100 min. for a Battery to be fully charged. Once charged, the unit is able to handle around 30,000 continuous first pass readings over a period of approximately 5 hours. Taking into account that that the scanner will go into standby mode while not in use for an average of 2.5 minutes, you can expect that in normal use the unit can be used for in excess of 8 hours per day with one battery pack.

MS9530 Voyager RF

12

Printed: September 2002

Version: 1.1

 

Status: Approved

Image 12
Contents MS9530 Series Voyager RF EML Handshaking Timeout Specifications Programming Modes MetroSet Software VersionEML Product Overview Base Station Unpacking List Connecting the Base Station to the Host Wedge Interface RS232 InterfaceLight PEN and Ocia Interfaces Read Enter/Exit Configuration Mode barcode Linking the Voyager RF to the Base StationRead Enter/Exit Configuration Mode barcode Fixing Voyager RF ID Numbers MS9530 Voyager RF Printed September Version Status Approved Base Station Testing Barcode Battery Pack RED GreenMS9530 Voyager RF Printed September Version Status Approved Visual Indicators Start Up SequenceSynchronisation Sequence Data Transmission SequenceLow Battery Message Programing Modes MetroSet Software Version EML Handshaking Timeout EMLSpecifications RF Link Specifications Specifications subject to change without noticeElectrical