VISUAL INDICATORS

The scanner has RED and GREEN LED’s. When the scanner is on, these visual indicators show the state of the scanner functionality.

Start Up Sequence

From Stand-by, once the user presses CodeGate button, the scanner goes into start-up mode.

Whilst in this mode, the YELLOW LED is displayed.

1.The scanner starts checking its OS (Operating system). If there is an error, RED and GREEN will be on and YELLOW will flash continuously.

2.The scanner will check Flash integrity. If there is an error, RED and GREEN will be on and YELLOW will flash once. After this the unit will enter into user RF Flash mode (Same as when METEOR RF Barcode is read. See how to load software via RF with METEOR RF for details)

After OS and Flash has been successfully checked, YELLOW LED is off and the unit will enter its own start-up sequence.

Synchronisation Sequence

Once the unit has finished all start-up sequences including Laser, Motor, Flash,…. tests, Voyager RF will take the following actions:

Show its ID( Mobile Identification number) by keeping RED and GREEN LEDs on while flashing YELLOW LED as many times as it own ID (1 to 5)

Link with base station.

The RED LED will flash several times while trying to synchronise. In case no link is made, the scanner will make a Razzberry tone with RED and GREEN LED’s on.

Once the reason why the link was not made (out of coverage area, Base powered off etc) is solved, the user is requested to press the CodeGate button to continue. A Beep tone will be executed and the RED and GREEN LED’s will be off.

Data Transmission Sequence

Once the unit has read a barcode, it will try to transmit the data to Base Station. Every time a transmission is performed, the RED led will flash and the scanner will wait for an acknowledgement from Base Station. If no ACK arrives after 14 tries, the unit will emit a Razzberry tone and the user will be requested to press the CodeGate button to continue.

MS9530 Voyager RF

14

Printed: September 2002

Version: 1.1

 

Status: Approved

Image 14
Contents MS9530 Series Voyager RF EML EML Handshaking Timeout SpecificationsProgramming Modes MetroSet Software Version Product Overview Base Station Unpacking List Light PEN and Ocia Interfaces Connecting the Base Station to the Host Wedge InterfaceRS232 Interface Read Enter/Exit Configuration Mode barcode Linking the Voyager RF to the Base StationRead Enter/Exit Configuration Mode barcode Fixing Voyager RF ID Numbers MS9530 Voyager RF Printed September Version Status Approved Base Station Testing Barcode Battery Pack RED GreenMS9530 Voyager RF Printed September Version Status Approved Synchronisation Sequence Visual IndicatorsStart Up Sequence Data Transmission SequenceLow Battery Message Programing Modes MetroSet Software Version EML Handshaking Timeout EMLElectrical Specifications RF Link SpecificationsSpecifications subject to change without notice