Version “17” Pin Assignments for Keyboard Wedge, RS-232 and Light Pen Emulation

The version “17” scanner head cable is terminated with a male 25-pin D-type connector. Connecting the scanner to a PC, requires a communication cable and a transformer. Connecting the communication cable to a PC, may require an adaptor cable. This can be ordered when the scanner is purchased.

The version “17” scanner is designed to be used as a keyboard wedge. However, with the appropriate communication cable, the scanner will also provide an RS- 232 or light pen emulation interface. When configuring the scanner for one interface versus another, change all necessary parameters for that particular interface. For instance, when configuring the scanner for keyboard wedge emulation, recall defaults, select the PC type, keyboard country type and intercharacter delay. For further information, refer to the ScanSelect Scanner Programming Guide or ScanSet Scanner Configuration Guide.

The following is a list of the pin assignments. The pin numbers are impressed on the head cable’s connector.

Pin

Function

Pin

Function

1

AC Shield Ground

14

Power Ground 1

2

RS-232 Receive Input

15

Light Pen Source

3

RS-232 Transmit Output

16

Light Pen Data

4

CTS Input

17

PC Data

5

RTS Output

18

PC Clock

6

Reserved

19

Power (11 - 30 volts) DC

7

Signal Ground

20

DTR Input

8 - 10

Reserved

21

Keyboard Clock

11

PC +5 Volts DC

22

Keyboard Data

12

Ground

23 - 24

Reserved

13

Earth Ground

25

Power Ground 2

39

Image 43
Contents Metrologic INSTRUMENTS, INC USA Corporate Headquarters Europe LocationsTable of Contents Appendix D Appendix aAppendix B Appendix CIntroduction Unpacking List Scanner Connections to the Host Configuration of the Scanner to the Host System Cloning Feature Version 11 IBM 46XX Scanner Configuring the MS860i-11 Scanner IBM 4684 and 4694 Systems Configuring the IBMPC Type Version 17 Keyboard Wedge ScannerConnection of a MS860i-17 Scanner to a PC Metrologic Part Number 45471, Installation Plate Installing the Scanner into a CounterAttaching the Vertical Stand to the Work Surface Touch Plate MS860i FeaturesPlaque de palpeur Touch PlatePiastra sensore Steady Green Visual IndicatorsNi la diode rouge, ni la diode verte nest allumée Signaux optiquesWeder rote noch grüne Leuchtdiodenanzeige Optische AnzeigenNé il diodo luminoso rosso né quello verde sono accesi Segnali otticiVolume Settings Labels Depth of Field Depth of Field and Symbol Specification See Figure Page Applications and Protocols MaintenanceElectrical SpecificationsAppendix a MechanicalEnvironmental OperationalAppendix B Default SettingsMecca DTS/SIEMENS DTS/NIXDORF NCR F NCR S Beep/Transmit Scanability Ocia IBM RTS/CTS Key Parallel Light Pin Function Appendix CEOT Version 2 Pin Assignments for Parallel CommunicationVersion 11 Pin Assignments for RS-485 Pin Function Version 3 Pin Assignments for Multi-drop RS-422 Version 26 Pin Assignments for RS-422 Appendix D Warranty and Disclaimer Limited WarrantyDisclaimer Remarque Appendix EAnmerkung Patents Appendix FVolume Control Card Page LED IndexMecca