Metrologic Instruments MS860 manual Version 11 IBM 46XX Scanner

Page 10

Version 11 IBM 46XX Scanner

Output Format:

IBM RS-485 serial input/output for the 4680 and 4690

 

(46XX) point-of-sale terminals

The Version 11 46XX interface can be used in several different ways. Both the 46XX terminal and the scanner must be configured to match each other.

Warning: Power to the scanner and 46XX terminal should be turned off before making physical connection.

The 4680 and 4690 series terminals have different types of physical ports for connecting bar code scanners. Scanner ports include Port 5B, Port 17, and Port 9? (? = A, B, C, or E). A Port 9 type connector is present on all versions of the 46XX families of terminals. That is one reason why it is the normal point of connection for Metrologic scanners. Another reason is that there is enough 12 volt power available to operate many Metrologic scanners. If your terminal configuration requires the use of a different physical port for connecting bar code scanners, contact Metrologic to get particular adaptor cable information.

All devices use a common communications bus inside the 46XX terminal, despite what port that is in use for the physical connection. Each device has a different address that it uses when it communicates. The terminal must be configured to look for a device at a logical address.

The IBM 1520 mode/address was selected as a default because it was the first IBM 46XX family scanner to support UPC/EAN, Code 39 and Interleaved 2 of 5 (I 2 of 5). The Version 11 scanner formats Codabar, Code 128, and Code 93 using the Code 39 function code designation supported by the IBM device driver for this scanner type. Other emulation modes currently available are the IBM 3687-2 Port 17 fixed scanner and the Port 9B IBM 4500 CCD hand-held bar code reader. The use one of these other emulation modes may be needed depending on which operating system (4680.OS, 4690.OS, POS/DOS or DOS/RIPPS) is in use at your site.

Note: The IBM 4683 and IBM 4684 terminals have a good proven track record of supplying power to Metrologic scanners. The IBM 4693 and IBM 4694 terminals may be restricted from supplying power to certain scanner models. Specifically, Metrologic currently recommends using an external power supply for the scanner when connecting to an IBM 4694. Metrologic has no recommendations at this time for IBM 4693 terminals.

6

Image 10
Contents Metrologic INSTRUMENTS, INC Locations USA Corporate Headquarters EuropeTable of Contents Appendix C Appendix aAppendix B Appendix DIntroduction Unpacking List Scanner Connections to the Host Configuration of the Scanner to the Host System Cloning Feature Version 11 IBM 46XX Scanner Configuring the MS860i-11 Scanner Configuring the IBM IBM 4684 and 4694 SystemsVersion 17 Keyboard Wedge Scanner PC TypeConnection of a MS860i-17 Scanner to a PC Installing the Scanner into a Counter Metrologic Part Number 45471, Installation PlateAttaching the Vertical Stand to the Work Surface MS860i Features Touch PlateTouch Plate Plaque de palpeurPiastra sensore Visual Indicators Steady GreenSignaux optiques Ni la diode rouge, ni la diode verte nest alluméeOptische Anzeigen Weder rote noch grüne LeuchtdiodenanzeigeSegnali ottici Né il diodo luminoso rosso né quello verde sono accesiVolume Settings Labels Depth of Field Depth of Field and Symbol Specification See Figure Page Maintenance Applications and ProtocolsMechanical SpecificationsAppendix a ElectricalOperational EnvironmentalDefault Settings Appendix BMecca DTS/SIEMENS DTS/NIXDORF NCR F NCR S Beep/Transmit Scanability Ocia IBM RTS/CTS Key Parallel Light Appendix C Pin FunctionVersion 2 Pin Assignments for Parallel Communication EOTVersion 11 Pin Assignments for RS-485 Pin Function Version 3 Pin Assignments for Multi-drop RS-422 Version 26 Pin Assignments for RS-422 Warranty and Disclaimer Limited Warranty Appendix DDisclaimer Appendix E RemarqueAnmerkung Appendix F PatentsVolume Control Card Page Index LEDMecca