Metrologic Instruments MS860 manual Appendix B, Default Settings

Page 32

Appendix B

Default Settings

The scanner is shipped from the factory programmed to a set of default conditions. The default parameter of the scanner has an asterisk ( * ) in the charts on the following pages. If an asterisk is not in the default column then the default setting is Off or Disabled.

Every communication does not support every parameter. If the communica- tion supports a parameter listed in the charts on the following pages, a check mark will appear.

For the scanner to communicate with your host system properly, program it to meet the specific scanning needs. Since each host system is unique, change the default settings to match the host system requirements. For information on how to change the default settings, refer to the Configuration of the Scanner to the Host System section or the ScanSelect™ Scanner Programming Guide.

 

 

 

 

 

 

 

 

 

 

Parameter

Default

OCIA

IBM

Key

RS-

Parallel

Light

 

 

 

 

46XX

Wedge

232*

 

Pen

 

UPC/EAN

*

T

T

T

T

T

T

 

Code 128

*

T

T

T

T

 

T

 

Code 93

*

T

T

T

T

 

T

 

Codabar

*

T

T

T

T

 

T

 

Interleaved 2 of 5

*

T

T

T

T

 

T

 

(ITF)

 

 

 

 

 

 

 

 

MOD 10 Check

 

T

T

T

T

 

T

 

on ITF

 

 

 

 

 

 

 

 

Code 11

 

T

T

T

T

 

T

 

Code 39

*

T

T

T

T

 

T

 

Full ASCII

 

T

T

T

T

 

T

 

Code 39

 

 

 

 

 

 

 

 

MOD 43 Check

 

T

T

T

T

 

T

 

on Code 39

 

 

 

 

 

 

 

 

MSI Plessey

 

T

T

T

T

 

T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28

Image 32
Contents Metrologic INSTRUMENTS, INC Locations USA Corporate Headquarters EuropeTable of Contents Appendix a Appendix BAppendix C Appendix DIntroduction Unpacking List Scanner Connections to the Host Configuration of the Scanner to the Host System Cloning Feature Version 11 IBM 46XX Scanner Configuring the MS860i-11 Scanner Configuring the IBM IBM 4684 and 4694 SystemsVersion 17 Keyboard Wedge Scanner PC TypeConnection of a MS860i-17 Scanner to a PC Installing the Scanner into a Counter Metrologic Part Number 45471, Installation PlateAttaching the Vertical Stand to the Work Surface MS860i Features Touch PlateTouch Plate Plaque de palpeurPiastra sensore Visual Indicators Steady GreenSignaux optiques Ni la diode rouge, ni la diode verte nest alluméeOptische Anzeigen Weder rote noch grüne LeuchtdiodenanzeigeSegnali ottici Né il diodo luminoso rosso né quello verde sono accesiVolume Settings Labels Depth of Field Depth of Field and Symbol Specification See Figure Page Maintenance Applications and ProtocolsSpecifications Appendix aMechanical ElectricalOperational EnvironmentalDefault Settings Appendix BMecca DTS/SIEMENS DTS/NIXDORF NCR F NCR S Beep/Transmit Scanability Ocia IBM RTS/CTS Key Parallel Light Appendix C Pin FunctionVersion 2 Pin Assignments for Parallel Communication EOTVersion 11 Pin Assignments for RS-485 Pin Function Version 3 Pin Assignments for Multi-drop RS-422 Version 26 Pin Assignments for RS-422 Warranty and Disclaimer Limited Warranty Appendix DDisclaimer Appendix E RemarqueAnmerkung Appendix F PatentsVolume Control Card Page Index LEDMecca