17
COMMAND CODE STRUCTURE
All commands sent to the unit must contain a leading code, the command code, and an ending code. Each command must be completely executed before the unit will accept a new command. When a command is completed, the unit provides a response code; "OK" indicates the command was received and executed,
"ERR" indicates there is a problem with the code and the command was not executed.
INLINE doublers and decoders can be set to recognize one of four sets of leading codes and ending codes.
These are: [ ] { } ( ) < > . The factory default for leading / ending codes is [ ]. The unit can only be set to a different command code by using an
A complete command consists of:
[ The leading code
CH4 The command code. In this case CH4 would select the RGB input.
] The ending code
Sample command codes:
[CH1] | Selects input 1 |
[GAM3] | Selects Gamma Correction curve 3 for the current input channel |
Controlling Multiple INLINE Products
INLINE products such as the Pathfinder,
When daisy chaining multiple units together the
CONTROL PORT PIN-OUTS
The
Pin# | Signal |
2 | Receive |
3 | Transmit |
5 | Ground |
©1994 - INLINE, INC. | IN1222 / IN1422 / IN1510 / IN1710 OPERATIONS MANUAL - REV. 2 12/04/99 |