Canon 4.1 manual How to Use this Guide, Where to Look, About the Conventions Used in this Guide

Page 3

How to Use this Guide

This guide explains the operating procedures for Canon Plug-in Module CS-U (hereafter referred to as Plug-in Module CS-U), the Macintosh driver (plug-in software) used with Canon image scanners.

Aplug-in is not an independent software program; it must be used within a plug-in compliant application, such as CanoScan Toolbox or Adobe Photoshop LE, to expand the capabilities of that program. Adding scanning capabilities to your computer is as easy as putting in a plug. Simply copy the Plug-in Module CS-U files to your computer.

Please read this guide to perform the installation procedures and scan. Store this manual in a handy location for future reference.

Where to Look

Quick Start Instructions p. 10

The Quick Start Instructions provide a brief summary of commands and procedures that will assist in using Plug-in Module CS-U immediately.

Scanning Preparations (Required Reading) p. 13

All users should read this section. This section describes the procedures and settings required before scanning, including positioning the original and selecting the output device, resolution, magnification and scanning mode.

Scanning (Required Reading) p. 29

All users should read this section to learn the procedures for scanning images and saving scanned images.

Adjusting Scanned Images p. 35

Read this section for details about how to adjust image brightness, color balance and other attributes. You can read this section as required.

Appendices

Read this section for troubleshooting tips, glossary terms and the index.

About the Conventions Used in this Guide

The following conventions are used in this guide to draw your attention to important information.

Caution:

This symbol is used to highlight procedural precautions and limitations. Always read these topics to avoid errors.

Hint:

This symbol is used to present helpful hints and supplemental information. Reading these topics is recommended to enhance your enjoyment of Plug-in Module CS-U.

3

Image 3
Contents Users Guide When you open the box How to Make Best Use of the ManualsHow to Use this Guide Where to LookAbout the Conventions Used in this Guide Table of Contents Adjusting Scanned Images Operating Environment Installing Plug-in Module CS-UPp -20Image Size Control Panel FeaturesE P Scanning ProceduresPlug-in Module CS-U Special Features Position materials for scanning and preview them. p Install Plug-in Module CS-UQuick Start Instructions Start Plug-in Module CS-U pMouse pointer over the image Verify Image Quality with the Browser Function beforeSpecify the Area of the Image to be Scanned Select the area to be scanned by clicking and draggingSave the image with Adobe Photoshop LE or other plug-in Scan the ImageSave the Scanned Image Click on the Scan buttonE P RGB Values Displaying the Plug-in Module CS-U Control PanelOperating Procedures Procedures Positioning OriginalsPlace the original on the scanners document glass Click on the Preview button PreviewingSelecting the Output Device Output Device Resolution= 720 dpi, Magnification= 100% Setting the Resolution and MagnificationSet the desired magnification factor on the control panel To Set the Magnification FactorSetting the Scan Mode Select a scan mode from the pop-up menu Click the arrow beside Scan ModeTo Verify the Image Verifying the Image before ScanningUse these buttons to rotate the image Rotating the ImageSetting Preferences Output DeviceAspect Ratio Preview Window UnitPlaten/Film Reset Default SettingsShut off lamp time Close Plug-in After ScanOperating Procedures Scanning Position the pointer in the preview window Setting the Scan AreaProcedures to Zoom ZoomingSelect the area you want to enlarge with the zoom function Click on the Zoom In button Click close box to guit the Plug-in Module CS-U ScanningTo Initiate the Scan Specify the Scan AreaEnter a name for the file and click the Save button Saving Scanned ImagesScanning Film Save Exposure Data Auto ExposureClick on the Scan button Remove Dust and Scratches CanoScan D2400U only Bit/14/16bit Grayscale and 24-bit/42/48bit Color Black & WhiteBit Color Tone Adjustment Dialog Tone AdjustmentHow to Interpret Histograms Histogram SettingsHow to Adjust Histograms To Adjust a HistogramShadow Mark Click on the OK buttonManipulating the Graph Tone Curve SettingsClick the OK button To Edit the Tone CurveGamma Value = Relationship Between the Tone Curve Image BrightnessBrightness and Contrast Settings ContrastBrightness To Adjust the Brightness and Contrast Operating Procedure Adjusting the Color BalanceGamma Value Settings Matching the Gamma Value to the Display CharacteristicsGamma value To Change the Gamma Value Settings To Set the Threshold Value Adjusting the Threshold ValueColorSync Auto Tone CorrectionTo Set the Auto Tone Correction RecommendedOpen the Image menu and select Unsharp Mask Unsharp MaskOpen the Image menu and select Descreen DescreenSelect High-speed Scan Mode from the Image menu High-speed Scan ModeSaving/Recalling Settings To Save Settings in a Settings FileClick the Save button To Recall a Settings File Scanning Techniques Matching Scan Resolution to PurposeAppendices Troubleshooting Problem Scan button cannot be selected Problem Scanning is taking a long time Problem Scanning quality is poor Error Messages Error Message CauseResponse Glossary Dot ColorImage File Optical ResolutionGrayscale HistogramPreview Area ResolutionPixel Plug-in SoftwareTone Curve Scan ModeShadows Threshold ValueOutput device 7, 11, 18, 25 IndexScan 12, 33 Scan area 11 Canon U.S.A., INC Canon Customer Support Help Desk