Canon 4.1 manual Problem Scan button cannot be selected

Page 62

Problem: Scan button cannot be selected

Solution 1: A scan cannot be performed if the scan area is set too small (less than 64 x 64 pixels). Increase the size of the scan area

Solution 2: A scan cannot be performed unless a scan area is specified. Specify a scan area

Solution 3: A scan cannot be performed if the required memory is larger than the free memory. Change the resolution (p. 19) or scan area

(p. 30) until the required memory is lower

Problem: The “Insufficient Memory” error message appears when scanning

Solution 1: Select the smallest possible area and rescan

Solution 2: Lower the resolution and magnification settings for the output device to the lowest possible values (p. 19)

Solution 3: Rescan after closing all the application programs other than the one used to start Plug-in Module CS-U

Solution 4: Rescan after you have restarted the application program used to start Plug-in Module CS-U

Solution 5: Quit the application program used to start Plug-in Module CS-U and increase the memory allocated to it. Click the application program icon once. Then open the [File] menu, choose [Get Info], and choose [Memory] from the submenu. Increase the memory in the Preferred Size box to at least 16,000 K.

Solution 6: Increase the amount of RAM as required

Problem: The [Image] menu [ColorSync] option cannot be used in Plug-in Module CS-U

Solution: ColorSync is not recognized after Mac OS upgraded to Version 9 after Plug-in Module CS-U was installed onto Mac OS 8.6. Reinstall Plug-in Module CS-U (p. 6)

62

Image 62
Contents Users Guide How to Make Best Use of the Manuals When you open the boxAbout the Conventions Used in this Guide How to Use this GuideWhere to Look Table of Contents Adjusting Scanned Images Installing Plug-in Module CS-U Operating EnvironmentControl Panel Features Pp -20Image SizeScanning Procedures E PPlug-in Module CS-U Special Features Start Plug-in Module CS-U p Install Plug-in Module CS-UQuick Start Instructions Position materials for scanning and preview them. pSelect the area to be scanned by clicking and dragging Verify Image Quality with the Browser Function beforeSpecify the Area of the Image to be Scanned Mouse pointer over the imageClick on the Scan button Scan the ImageSave the Scanned Image Save the image with Adobe Photoshop LE or other plug-inE P Displaying the Plug-in Module CS-U Control Panel RGB ValuesOperating Procedures Place the original on the scanners document glass ProceduresPositioning Originals Previewing Click on the Preview buttonSelecting the Output Device Setting the Resolution and Magnification Output Device Resolution= 720 dpi, Magnification= 100%To Set the Magnification Factor Set the desired magnification factor on the control panelSetting the Scan Mode Click the arrow beside Scan Mode Select a scan mode from the pop-up menuVerifying the Image before Scanning To Verify the ImageRotating the Image Use these buttons to rotate the imageAspect Ratio Setting PreferencesOutput Device Unit Preview WindowClose Plug-in After Scan Reset Default SettingsShut off lamp time Platen/FilmOperating Procedures Scanning Setting the Scan Area Position the pointer in the preview windowSelect the area you want to enlarge with the zoom function Procedures to ZoomZooming Click on the Zoom In button Specify the Scan Area ScanningTo Initiate the Scan Click close box to guit the Plug-in Module CS-USaving Scanned Images Enter a name for the file and click the Save buttonScanning Film Auto Exposure Save Exposure DataClick on the Scan button Remove Dust and Scratches CanoScan D2400U only Bit Color Bit/14/16bit Grayscale and 24-bit/42/48bit ColorBlack & White Tone Adjustment Tone Adjustment DialogHistogram Settings How to Interpret HistogramsTo Adjust a Histogram How to Adjust HistogramsClick on the OK button Shadow MarkTone Curve Settings Manipulating the GraphTo Edit the Tone Curve Click the OK buttonRelationship Between the Tone Curve Image Brightness Gamma Value =Brightness Brightness and Contrast SettingsContrast To Adjust the Brightness and Contrast Adjusting the Color Balance Operating ProcedureGamma value Gamma Value SettingsMatching the Gamma Value to the Display Characteristics To Change the Gamma Value Settings Adjusting the Threshold Value To Set the Threshold ValueRecommended Auto Tone CorrectionTo Set the Auto Tone Correction ColorSyncUnsharp Mask Open the Image menu and select Unsharp MaskDescreen Open the Image menu and select DescreenHigh-speed Scan Mode Select High-speed Scan Mode from the Image menuClick the Save button Saving/Recalling SettingsTo Save Settings in a Settings File To Recall a Settings File Matching Scan Resolution to Purpose Scanning TechniquesAppendices Troubleshooting Problem Scan button cannot be selected Problem Scanning is taking a long time Problem Scanning quality is poor Response Error MessagesError Message Cause Glossary Color DotHistogram Optical ResolutionGrayscale Image FilePlug-in Software ResolutionPixel Preview AreaThreshold Value Scan ModeShadows Tone CurveIndex Output device 7, 11, 18, 25Scan 12, 33 Scan area 11 Canon Customer Support Help Desk Canon U.S.A., INC