2.3Installing the Hardware

To properly connect the HC15 module and all accessories to the DSB75 Board follow these steps:

Check that the all switches of the DSB75 Board are set as described in the Appendix.

Attach the adapter board to the 80-pin header located on the DSB75 Board. Take gentle care that all pins are aligned correctly, then press down evenly on the adapter board until it is firmly seated.

Connect the one end of the mini antenna to the Hirose U.Fl connector of the DSB75 board and attach the other end to the Hirose U.FL connector located on the module’s top side.

Mount the HC15 module upside down onto the 50-pin board-to-board connector of the adapter board.

Screw the external antenna (MiniMag) into the SMA connector on the DSB75. To improve the antenna performance use the metal plate for grounding. The external antenna should be positioned in the center of the metal plate.

Connect the Western plug of the handset to the Western jack on the DSB75.

Make sure that the power supply adapter is switched to 9 Volts, and connect the power cables to the red and black connectors of the DSB75.

Plug the USB cable to the computer’s USB port and to the USB port of the DSB75. See Chapter 2.4 to continue.

DSB75 board

Mini antenna cable

Adapter board

50-pin board-to-board connector

Hirose U.Fl connector

SMA connector

Western jack

SIM card reader

for handset

 

Figure 1: DSB75 with adapter board and mini antenna cable

HC15_startup_v01

Page 7 of 31

2007-01-22

Image 7
Contents User’s Guide Getting Started with HC15 Getting Started with HC15Figures ContentsRelated Documents IntroductionTechnical Requirements for Running HC15 on DSB75 Installation and ConfigurationGetting Started with HC15 Installing the Hardware Getting Started with HC15 Installing USB and Ethernet Drivers Getting Started with HC15 Next Siemens Hsdpa USB Modem Installed Devices and ToolsSiemens Wireless Ethernet Adapter Uninstalling Drivers and the Connection ManagerSiemens USB Com Port Uninstalling Earlier Drivers Uninstalling Drivers and Tools from Earlier HC15 ReleasesUninstalling Earlier Connection Manager AT Command Interpreter Using the HC15 ModuleSwitching off the HC15 Switching on the HC15Registering to the Network Selecting Umts or GSM Defining the PDP Context Attaching to the Hsdpa or Gprs NetworkAnswering a Voice Call MT Making a Voice Call MOHsdpa or Gprs Data Transfer Hsdpa or Gprs Data Transfer via Dial-Up Network Terminating the dial-up connection Appendix Adding and Configuring a New Dial-Up ConnectionAdding a New Dial-up Connection Getting Started with HC15 Getting Started with HC15 Configuring a Dial-up Connection Getting Started with HC15 Most cases, it is sufficient to accept the default settings Abbreviation Description AbbreviationsHC15-DSB75 adapter board switch settings Do not use X201, X202