Behringer manual Denoiser SNR2000

Page 14

DENOISER SNR2000

2.4.1 THRESHOLD control

The THRESHOLD control of the expander defines the operating level. It stretches across a very wide range and therefore applies to all working levels. Input levels above the adjusted threshold point do not experience any change. However, if the level falls below the threshold the dynamic process is active.

For example, if the THRESHOLD control was set at 0 dBu and the input signal drops below 0 dBu, downward expansion will begin. In typical applications the setting of the threshold control should be between 5 and 20 dB above the quiescent noise floor of the input signal. For example, if the quiescent noise floor was -40 dBu, a setting between -35 to -20 dBu will produce the desired expansion.

+With the RATIO control set to maximum and the THRESHOLD control set at +10 dBu, an input signal level would have to exceed approximately +5 dBu to produce an output signal.

2.4.2 RELEASE control

The RELEASE control determines the time the downward expander requires to decrease the level of the output signal. The RELEASE control is variable from 0.2 to 4 seconds and refers to a 20 dB gain change. The ultimate setting of the RELEASE control depends on your demands: When the expander sections are supposed to function as gates, settings between 0.2 and 0.5 seconds are recommended.

For individual instruments or vocals use a setting between 0.2 and 0.5 seconds. For composite music a setting between 0.6 and 2 seconds is recommended. If you want to use the expander section to reduce subtle background noise from effects devices, a very slow release time (2 to 6 seconds) would be perfect.

2.4.3 RATIO control

The ratio between input and output level for all signals that fall below the threshold is called expansion ratio. It is adjustable via the RATIO control. This control adjusts an important parameter: It determines whether the section functions as expander or gate.

A ratio of 1:1 indicates that the output signal will correspond to the input signal, i.e. the level does not change. A ratio of 1:2 indicates that for every 1 dB decrease in input level below the threshold, there will be resultant corresponding decrease in the output level of 2 dB. A ratio of 1:6 indicates, that for a 1 dB decrease in input level below the threshold, there will be a corresponding decrease in the output level of 6 dB etc.

Low ratios from 1:1 to about 1:3 produce precisely controlled downward expansion. At more pronounced settings up to 1:6 the DENOISER functions as gate.

The scale of the ratio is calibrated in dB on the front panel. It indicates the decrease in output level, resulting from a 1 dB decrease in input level.

The DENOISER works as an IRC expander. The interactive control function defines the soft onset of the expander, according to the characteristics of human hearing during the fade out process. This allows for a natural and thus inaudible elimination of interference noise. This means that, as the input level drops slightly below the threshold point, the expander ratio will start at 1.1:1 and increase to an ultimate ratio selected with the RATIO control. The correct setting of the ratio control depends on your demands: In order to achieve a flat expansion curve, we recommend settings of 1:1 to 1:3. This provides soft and limited expansion for difficult and noisy audio applications. Higher settings up to 1:6 are recommended for gating applications which allow for noise reduction of more than 70 dB.

2.4.4 GAIN REDUCTION meter

The eight GAIN REDUCTION LEDs on the front panel of the BEHRINGER DENOISER function as follows: If the input level falls below the threshold, the expander starts working with the current level reduction factor being indicated by the GAIN REDUCTION LEDs.

Let us consider, for example, a specific signal that falls by 2 dB below the threshold: with a ratio setting of 1:6, the output signal is attenuated by 12 dB; in comparison to the input signal the output signal has been reduced by 12 dB, which is indicated by the 10 dB LED.

Although the VCA of the BEHRINGER DENOISER provides a control range of 80 dB, it is not very useful to display the entire range, since such drastic control processes are performed very rarely in practice. The displayed range of the GAIN REDUCTION indicators is 40 dB.

14

2. OPERATION

Image 14
Contents User’s Manual Safety Instructions Detailed Safety InstructionsForeword Denoiser Table of Contents Introduction Design conceptBefore you begin Control elementsFront panel control elements Operation Operation of the filter sectionTAC filter of the Denoiser Operation of the dynamic filterDenoiser SNR2000 Operation of the expander section IRC expander of the Denoiser Function of an expanderDenoiser SNR2000 Couple function Initial settings of the DenoiserApplications We recommend the following control settings Studio applicationsNoise reduction during recording Noise reduction in the effects bus Noise reduction on keyboards Technical Background What are audio dynamics?Compressors/limiters Expanders/noise gatesCompanders Downward expansionNoise as physical phenomenon Rack mounting InstallationSingle-ended principle Audio connectionsSpecifications THD Warranty § 1 Warranty CARD/ONLINE Registration § 2 Warranty