SW-A6 No. 2 End buzzer
Setting this bit to 0 will disable the end buzzer (including the error buzzer/
Bit1= 0: When DIS signal is received during RX mode, disconnected the line is immediately.
Bit1= 1: When DIS signal is received during RX mode, wait the next signal.
SW-A6 No. 4 Equalizer freeze control (MODEM)
This switch is used to perform reception operation by fixing the equal- izer control of modem for the line which is always in unfavorable state and picture cannot be received.
*Usually, the control is executed according to the state of line where the equalizer setting is changed always.
SW-A6 No. 5 Equalizer freeze control 7200BPS only
Setting which specifies
SW-A6 No. 6 CNG transmission in manual TX mode
When set to "1", fax transmit the CNG signal in case of manual trans- mission mode (User press the START key after waiting the fax answer- ing signal from handset or speaker).
When set to "0", if the other fax is Sharp model, fax transmit the docu- ment by H2 mode. When set to "1", even if the other fax is Sharp model, fax transmit the document by MR mode.
SW-A6 No. 8 Reserved
Set to "0".
SW-B1 No. 1 ~ No. 4 Recall interval
Choice is made for a redial interval for speed and rapid dial calls. Used a binary number to program this. If set to 0 accidentally, 1 will be assumed.
SW-B1 No. 5 ~ No. 8 Recall times
Choice is made as to how many redials should be.
SW-B2 No. 1 Dialing pause (sec/pause)
Pauses can be inserted between telephone numbers of direct dial con- nection. Selection of 4 sec or 2 sec pause is available.
SW-B2 No. 2, No. 3 Reserved
Set to "0".
SW-B2 No. 4 Busy tone detection (after auto dial)
Used to set YES/NO of busy tone detection after auto dialing.
SW-B2 No. 5 Waiting time after dialing
This is waiting time for the opponent’s signals after dialing.
When set to "0", waiting time is 45 sec.
When set to "1", waiting time is 90 sec.
SW-B2 No. 6 ~ No. 8 Reserved
Set to "0".
SW-B3 No. 1 ~ No. 7 Reserved
Set to "0".
SW-B3 No. 8 Hold function
Used to set YES/NO of holding function by the HOLD key.
SW-B4 No. 1 Auto dial mode Delay timer of before line connect
Delay time between the dial key input and line connection under the auto dial mode.
RAPID01 | CML RELAY ON |
|
|
DIALLING
0 : 0sec
1 : 3sec
SW-B4 No. 2 Auto dial mode Delay timer of after line connect
Delay time between the line connection and dial data output under the auto dial mode.
DIAL DATA
RAPID01 | CML RELAY ON | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0 : 3 sec
1 : 3.6 sec
SW-B4 No. 3 Dial mode
When using the pulse dial, set to 0. When using the tone dial, set to 1. key
When setting to 1, the mode is changed by pressing the key from the pulse dial mode to the tone dial mode.
SW-B4 No. 5 Dial pulse make/break ratio (%)
When using the 33 % make ratio pulse dial, set to "0". When using the 40 % make ratio pulse dial, set to "1".
SW-B4 No. 6 ~ No. 8 Reserved
Set to "0".
SW-B5 No. 1 ~ No. 5 DTMF signal transmission level (Low)
The transmission level of DTMF signal is adjusted. (lower frequency) 00000: 0dBm
↓
11111:
SW-B5 No. 6 ~ No. 8 Reserved
Set to "0".
SW-B6 No. 1 ~ No. 5 DTMF signal transmission level (High)
The transmission level of DTMF signal is adjusted. (higher frequency)
00000: 0dBm
↓
11111:
SW-B6 No. 6 ~ No. 8 Reserved
Set to "0".
SW-C1 No. 1, No. 2 Reading slice (Binary)
Used to determine the set value of reading density in standard/fine mode. The standard setting is "00" (Factory setting is "00")
SW-C1 No. 3, No. 4 Reading slice (Half tone)
Used to determine the set value of reading density in half tone mode. The standard setting is "00" (Factory setting is "00")
SW-C1 No. 5 Line density selection
Used to set the transmission mode which is automatically selected when the Resolution key is not pressed. In the copy mode, however, the fine mode is automatically selected unless the Resolution key is manually set to another mode.
SW-C1 No. 6 Reserved
Set to "0".
SW-C1 No. 7 MTF correction in half tone mode
This allows selection of MTF correction (dimness correction) in the half tone mode.
When "NO" (=1) is selected, the whole image becomes soft and mild. On the contrary, however, clearness of characters will be reduced. Nor- mally set to "YES" (=0).
Set to "0".
2 – 13