Sharp FO-475TH Externally connected TEL OFF Hook detection circuit section, CI detection circuit

Page 51

UX-258TH

FO-475TH

5.Externally connected TEL OFF HOOK detection circuit section

The circuit current detection is turned on together with OFF HOOK of main body or OFF HOOK of externally connected TEL. ON of CML OFF is judged as OFF HOOK of externally connected TEL.

6.CI detection circuit

CI is detected by the photocoupler which is integrated in series in the primary side TEL circuit well proven in the existing unit.

7.Signal/DTMF transmission level & receiving level

Signal transmission level setting: ATT 7 dB Circuit output: 7 dBm.

DTMF transmission level setting: HF -6.0 dBm

LF -7.0 dBm

Thus, set the level.

 

Attenuation in the LIU section of the receiving level is degigned at -6 dBm. (The modem and circuit error are not included.)

7.Signal selection

The following signals are used to control the transmission line of TEL/ FAX signal. For details, refer to the signal selector matrix table.

[Control signals from output port]

Signal Name

 

 

Description

 

 

CML

Line connecting relay and DP generating relay

 

(The circuit is located

H: Line make

 

 

 

 

 

 

in the TEL/LIU PWB.)

L: Line break

 

 

 

 

 

 

SP MUTE

Speaker tone mute control signal

 

 

(The circuit is located H: Muting (Power down mode)

 

 

in the TEL/LIU PWB.) L: Muting cancel (Normal operation)

 

 

 

 

 

 

Handset reception mute control signal

 

TEL MUTE

H: Muting

 

 

 

 

 

 

 

L: Muting cancel

 

 

 

 

 

 

 

 

 

 

 

Speaker volume control signal,

 

 

 

 

VOL A VOL B VOL C matrix

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

VOL A

 

VOL B

VOL C

 

OH-HOOK

 

 

 

 

Receiving

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X0

L

 

L

L

 

 

 

X1

H

 

L

L

 

 

 

X2

L

 

H

L

 

HIGH

 

 

X3

H

 

H

L

 

MIDDLE1

 

VOL A

X4

L

 

L

H

 

MIDDLE2

 

VOL B

X5

H

 

L

H

 

MIDDLE3

 

VOL C

X6

L

 

H

H

 

LOW

 

(The circuit is located

X7

H

 

H

H

 

 

in the control PWB.)

 

 

 

 

 

 

 

 

 

OUTPUT

RINGER

 

BUZZER

DTMF

 

ICM/OGM

 

 

 

 

 

 

 

 

 

 

 

X0

 

 

HIGH

 

 

X1

HIGH

 

 

MIDDLE1

 

 

X2

 

 

MIDDLE2

 

 

X3

MIDDLE

 

HIGH

 

MIDDLE3

 

 

X4

 

FIXED

MIDDLE1

 

 

 

X5

 

MIDDLE2

 

LOW

 

 

X6

 

MIDDLE3

 

 

 

X7

LOW

 

LOW

 

 

The volume settings of ON-HOOK receiving, DTMF and ICM/OGM must be performed to- gether. (The setting of RINGER must be per- formed separately.)

TXCONT

TXOUT mute signal

L: Signal sending, when transmitting

(The circuit is located

H: During reception, transmission mute,

in the control PWB.)

(during standby)

 

GAIN-C

Reception gain switching signal

(The circuit is located

H: When connected to line, 1: 1 gain

in the control PWB.)

L: When not connected to line, HIGH gain

BZCONT

Speaker output signal switching

(The circuit is located

H: Buzzer signal output

in the control PWB.)

L: When monitoring line signal

5 – 9

Image 51
Contents Facsimile Il y a danger d’explosion s’ il y a remplacement incorrect Specifications Operation panel Transmittable documents Connections InstallationUse of Document Carrier Sheet Site selectionLoading the fax paper Original document supportClearing jammed fax paper Clearing a jammed documentTransmitting documents Using the answering machineQuick reference guide Function key menuAdjustments Diagnostics and service soft switch Operating procedure Entering the diagnostic modeDiagnostic items Signal send mode Diagnostic items description Soft switch modeAging mode Check pattern modeFlash memory clear How to make soft switch settingEntry data receive Flash memory checkSoft switch description DataOption No. = X 60 sec = 5 min Recall times Binary input Light Dark Darker TEL 0~9 No. = CNG detection in STAND-BY mode Yes Fax switching when A.M. full Yes 10 ~ 25 dBm No. = 12 dB AGC eref access code line Reserved Speaker volume 5 stages Soft switch function description SW-B4 No Dial mode SW-A6 No CNG transmission in manual TX modeSW-B4 No Auto dial mode Delay timer of before line connect SW-B4 No Auto dial mode Delay timer of after line connectSW-F2 No CNG detection in STAND-BY mode SW-D1 No Automatic switching manual to auto receive modeSW-E1 No Tel/Fax Automatic switching mode SW-E1 No CNG detect time at TEL/FAX modeSW-H1 No Busy tone continuous sound detect time SW-H2 No Fax switching when A.M. fullSW-I2 No Alarm during two way recording SW-H1 No ReservedSW-K1 No Entering Diag mode by pressing Speed key SW-J1 No Sender’s phone number settingSW-J1 No , No Ringer volume SW-J2 No ~ No Speaker volume 5 stagesATT TroubleshootingError code table Communication error code table G3 TransmissionG3 Reception General description Recording block 5-1. General view Documents requiring use of document carrierDocument release General Cross section viewHandset cover and paper support guide Disassembly and assembly proceduresPWB case top, bottom and PWB Operation panel unit and scanner frame Screwdriver Hook CIS support 11 ,13 Stopper plateDocument guide upper unit and head frame Document guide upper Operation panel GAP Hopper Guide R Guide LLCD PWB Drive unit, PWB and cutter 1211Speaker and paper sensor lever Rib1811 Drive frameWire treatment TEL/LIUPWB Cutter Block diagramTEL/LIU PWB Unit Wiring diagramPower Supply PWB Unit Control PWB UnitPoint- to-point diagram Circuit description Description of each block Main control block Circuit description of control PWBFC200 IC2 Terminal descriptions GPIO1/SASTXD 2XC Ledctl 4XCLcdcs 1XC GPIO0 2XCMechanism/recording control block Panel control blockIntroduction Modem R96V24 blockPin Signals 100-Pin Pqfp R96V24 IC1 Hardware Interface SignalsCircuit description Block diagramCircuit description of TEL/LIU PWB TEL/LIU block operational descriptionCI detection circuit Signal/DTMF transmission level & receiving levelSignal selection Externally connected TEL OFF Hook detection circuit sectionExample TEL speaking Circuit description of CIS unit Circuit description of power supply PWBControlPWB Circuit Block44PIN Tsop Memory blockIC3 Modem2902 Other blockULN2003A Video processing/Motor drive / Thermal blockIC5 Analog signal blockControl PWB parts layout Top side Control PWB parts layout Bottom side TEL/LIU PWB circuit These marks are all safety-critical partsTEL/LIU PWB parts layout NJM78M05FA Power supply PWB circuitPower supply PWB parts layout IC101 74HC147 Operation panel PWB circuitProtocol Operation FlowchartPower on sequence Service tools ListRelay board unit OFF Description Relay board unitShading paper IC3 VHiMC74HCU04FMC74HCU04F IC6, 10 VHiHCF4053M1T HCF4053B IC signal nameIC13 VHiULN2003AN/ ULN2003A IC7 VHiW24257S7LL W24257S-70LLTIC100 VHiPST596CMT1 PST596CNR IC11, 12 VHiLM2902D/-1 LM2902D IC8 VHi27C02015TiIC5 VHiHEF4051BT1 HEF4051BT IC4 VHiMC34119DR2 MC34119DR2IC1 VHiR96FC20V24 R96V24 IC1 VHiNJM2904D-1 NJM2904D IC2 VHiR96FC20V24 FC200