Example:
If cards 1, 2, and 3 are grouped as group 5 of unit 1, send the command [SEL1G5U1]. Then send the commands [ + ], and [ - ] to increase or decrease the volume for cards 1, 2, and 3 simultaneously.
5.[SEL]
This command selects the individual input for adjusting the volume level of each output.
Command Format: [SELmCnUi]
SELm = volume select for output m. (m =
Cn = card ID (n = from 1 to 19)
After the [SEL] command is executed, the [ + ] and [ - ] commands must be executed immediately in order to increase or decrease the volume. Any other command (or an empty command such as [ ] ) will terminate the [SEL] command.
6.[VOL]
This command allows the
Command Format: [VOLmAnCi] VOLm = output select (m = 1 to 4) An = amplitude level (n = 0 to 16) Ci = card ID (i = from 1 to 19)
Example:
If there is an
7.[CLR] - Card
The command clears all volumes to maximum for a single card. With this command, 200ms is
needed for execution. Insert a 200ms delay [WAIT] time after sending this command.
[CLRCnUi]
Cn = card ID No. (n = slot # from 1 to 19)
Ui = Unit ID number (i = 0 to 9)
After [CLR] is executed, send [Cn] and receive feedback as:
Vol1=16/16
Vol2=16/16
Vol3=16/16
Vol4=16/16
8.[…S] – Save
This command will save the volume configuration command being sent in memory. When sending the command [VOL1A10C4S], after reset or power up, the volume level of output 1 on C4 will be level 10.
9.[CLR] - Group
This command clears the members for all nine groups.
[CLRGkUi]
Gk = group number (k = # from
Example:
a)To clear group #1, send the command [CLRG1U1]. This command clears the members for the specified group only.
b)To clear all groups of unit 1, send the command [CLR G[U1].
10.[WR]
This command groups multiple cards in the
Command Format: [WRCn… GkUi]
Cn = card ID No. (n = slot # from 1 to 19)
Gk = group number (k = # from
8