Shelf Status Summary Screen
The Shelf Status Summary Screen shown in Figure 9 provides a
HDSL / HDSL2 Status Screen
From the Shelf Status Summary Screen, detailed information related to a particular circuit may be accessed. The HDSL / HDSL2 Shelf Status Summary
screen related to a particular slot may be displayed by typing the desired slot number and S. For example, to access Slot 6 information, type 6S. The HDSL / HDSL2 Status Summary Screen is shown in Figure 10. This screen gives both local and remote performance and provisioning information for the selected slot. If a supported HRE is present in the HDSL / HDSL2 circuit, screen 10A is available to view the performance of the HRE.
08/08/70 | 17:59:19 |
|
|
| SHELF ADDRESS = 00 | |
|
| SHELF STATUS SUMMARY | [ BYPASS = OFF ] |
| ||
ACTIVE SHELF ALARMS |
| HFAC ALARM THRESHOLD OPTION | SETTINGS | |||
| ||||||
CRITICAL | - YES |
| ES |
| SES | UAS |
MAJOR | - NO | SLOT | TYPE THRSHLD | TYPE THRSHLD | TYPE THRSHLD | |
MINOR | - NO |
|
| 1: | ||||||
FUSE ALARM SETTINGS | 2: | |||||||
3: | ||||||||
HFAC | : CRIT | 4: | ||||||
5: | ||||||||
| 6: | |||||||
|
| 7:* | MAJ | 150 | MAJ | 075 | CRIT | 075 |
|
| 8: | ||||||
| LEGEND | 9: | ||||||
10: | ||||||||
NA | = NOT ALARMED | 11: | ||||||
* | = DEFAULT | 12:* MAJ | 150 | MAJ | 075 | CRIT | 075 | |
— | = EMPTY SLOT | 13:* MAJ | 150 | MAJ | 075 | CRIT | 075 | |
PRESS | : “O” - change options, | “D” | - read HFAC switch defaults (all slots), | |||||
| nn”S” - slot select | (HDSL STATUS), | “M” - main menu : |
|
|
Figure 9. Shelf Status Summary Screen
08/08/70 | 18:00:37 | SUMMARY | - [ SLOT 7 | ] |
| SHELF | ADDRESS = 00 | ||||
LOOP #1 <NETWORK> LOOP #2 | ELAPSED | TIME 00:09:56 |
| LOOP #1 <CUSTOMER>LOOP #2 | |||||||
|
|
|
|
|
| ||||||
01 dB |
| 01 dB |
| <- | LOSS |
|
| 01 dB |
| 01 dB | |
YES |
| YES |
| <- | SYNC |
|
| YES |
| YES | |
000/00001 |
| 000/00001 |
| <- ES | 15M/24H |
| 000/00001 |
| 000/00001 | ||
000/00000 |
| 000/00000 |
| <- SES | 15M/24H |
| 000/00000 |
| 000/00001 | ||
000/00026 |
| 000/00025 |
| <- UAS | 15M/24H |
| 000/00026 |
| 000/00025 | ||
LOOPBACKS INACTIVE |
|
|
|
|
|
| LOOPBACKS INACTIVE | ||||
|
|
|
| DS1 | QUALITY | ||||||
[X] | 9 | [X] |
| [X] | 9 | [X] |
|
| |||
L[X] | 8 | L[X] | SF | <- | FRAME |
| SF | L[X] | 8 | L[X] | |
O[X] | 7 | O[X] | AMI | <- | CODE |
| AMI | O[X] | 7 | O[X] | |
O[X] | 6 | O[X] | EXT | <- | LBO |
| 0 dB | O[X] | 6 | O[X] | |
P[X] | 5 | P[X] | N/A | <- | NIU |
| NO | P[X] | 5 | P[X] | |
[X] | 4 | [X] | 00000 | <- | BPV |
| 00000 | [X] | 4 | [X] | |
1[X] | 3 | 2[X] | 00000 | <- | ES |
| 00000 | 1[X] | 3 | 2[X] | |
[X] | 2 | [X] | 00000 | <- | SES |
| 00000 | [X] | 2 | [X] | |
[X] | 1 | [X] | 00324 | <- | UAS |
| 00302 | [X] | 1 | [X] | |
[X] | 0 | [X] | RED | <- | ALARMS |
| RED | [X] | 0 | [X] | |
|
|
| SEALING | CURRENT PRESENT |
|
|
| ||||
|
| “P” - prev scrn, |
|
|
|
|
|
|
|
| |
|
| “M” - main menu, | “Z” - | clr current reg, | nn”S” - slot: |
|
Figure 10. Status Summary Screen
10 |
|
|