ADTRAN E220 HFAC HDSL2 specifications Shelf Status Summary Screen, Hdsl / HDSL2 Status Screen

Page 10

Shelf Status Summary Screen

The Shelf Status Summary Screen shown in Figure 9 provides a top-level look at the alarm and provisioning of data for the shelf and each circuit within the shelf.

HDSL / HDSL2 Status Screen

From the Shelf Status Summary Screen, detailed information related to a particular circuit may be accessed. The HDSL / HDSL2 Shelf Status Summary

screen related to a particular slot may be displayed by typing the desired slot number and S. For example, to access Slot 6 information, type 6S. The HDSL / HDSL2 Status Summary Screen is shown in Figure 10. This screen gives both local and remote performance and provisioning information for the selected slot. If a supported HRE is present in the HDSL / HDSL2 circuit, screen 10A is available to view the performance of the HRE.

08/08/70

17:59:19

 

 

 

SHELF ADDRESS = 00

 

 

SHELF STATUS SUMMARY

[ BYPASS = OFF ]

 

ACTIVE SHELF ALARMS

 

HFAC ALARM THRESHOLD OPTION

SETTINGS

—————————

 

——————————————————————————————————————————————————————

CRITICAL

- YES

 

ES

 

SES

UAS

MAJOR

- NO

SLOT

TYPE THRSHLD

TYPE THRSHLD

TYPE THRSHLD

MINOR

- NO

----

-------------

-------------

-------------

 

 

1:

---

---

---

---

---

---

FUSE ALARM SETTINGS

2:

---

---

---

---

---

---

——————————————————

3:

---

---

---

---

---

---

HFAC

: CRIT

4:

---

---

---

---

---

---

HTU-C : 1-5 = MAJ,

5:

---

---

---

---

---

---

 

6-13 = CRIT

6:

---

---

---

---

---

---

 

 

7:*

MAJ

150

MAJ

075

CRIT

075

 

 

8:

---

---

---

---

---

---

 

LEGEND

9:

---

---

---

---

---

---

——————————————————

10:

---

---

---

---

---

---

NA

= NOT ALARMED

11:

---

---

---

---

---

---

*

= DEFAULT

12:* MAJ

150

MAJ

075

CRIT

075

= EMPTY SLOT

13:* MAJ

150

MAJ

075

CRIT

075

PRESS

: “O” - change options,

“D”

- read HFAC switch defaults (all slots),

 

nn”S” - slot select

(HDSL STATUS),

“M” - main menu :

 

 

Figure 9. Shelf Status Summary Screen

08/08/70

18:00:37

SUMMARY

- [ SLOT 7

]

 

SHELF

ADDRESS = 00

LOOP #1 <NETWORK> LOOP #2

ELAPSED

TIME 00:09:56

 

LOOP #1 <CUSTOMER>LOOP #2

---------

HTU-C ---------

 

 

 

 

 

 

--------- HTU-R ---------

01 dB

 

01 dB

 

<-

LOSS

 

->

 

01 dB

 

01 dB

YES

 

YES

 

<-

SYNC

 

->

 

YES

 

YES

000/00001

 

000/00001

 

<- ES

15M/24H

->

 

000/00001

 

000/00001

000/00000

 

000/00000

 

<- SES

15M/24H

->

 

000/00000

 

000/00001

000/00026

 

000/00025

 

<- UAS

15M/24H

->

 

000/00026

 

000/00025

LOOPBACKS INACTIVE

 

 

 

 

 

 

LOOPBACKS INACTIVE

HTU-C SIGNAL QUALITY

DSX-1

 

 

 

 

DS1

HTU-R SIGNAL

QUALITY

[X]

9

[X]

———————————————

 

[X]

9

[X]

 

 

L[X]

8

L[X]

SF

<-

FRAME

->

 

SF

L[X]

8

L[X]

O[X]

7

O[X]

AMI

<-

CODE

->

 

AMI

O[X]

7

O[X]

O[X]

6

O[X]

EXT

<-

LBO

->

 

0 dB

O[X]

6

O[X]

P[X]

5

P[X]

N/A

<-

NIU

->

 

NO

P[X]

5

P[X]

[X]

4

[X]

00000

<-

BPV

->

 

00000

[X]

4

[X]

1[X]

3

2[X]

00000

<-

ES

->

 

00000

1[X]

3

2[X]

[X]

2

[X]

00000

<-

SES

->

 

00000

[X]

2

[X]

[X]

1

[X]

00324

<-

UAS

->

 

00302

[X]

1

[X]

[X]

0

[X]

RED

<-

ALARMS ->

 

RED

[X]

0

[X]

 

 

 

SEALING

CURRENT PRESENT

 

 

 

 

 

“P” - prev scrn,

 

 

 

 

 

 

 

 

 

 

“M” - main menu,

“Z” -

clr current reg,

nn”S” - slot:

 

Figure 10. Status Summary Screen

10

61221051L1-5, Issue 1

61221051L1-5A

Image 10
Contents General L1-5A Issue 1, AprilClei # T1L4FFCC Revision HistoryElectrical cable compliance InstallationConfiguration Shelf Address61221051L1-5A 61221051L1-5, Issue Errored Seconds ES AlarmS1 Switch Options arrow indicates default setting Unit OptionsS3 Switch Options arrow indicates default setting S2 Switch Options arrow indicates default setting61221051L1-5, Issue 61221051L1-5A Unavailable Seconds UAS Alarm Severely Errored Seconds SES AlarmHfac Alarm Outputs Hfac Fuse Alarm HTU-C Fuse AlarmAlarms ConnectionsControl Port Operation Faceplate FeaturesHfac Faceplate Features Screen AbbreviationsScreen Abbreviations Main MenuIntroductory Menu Shelf Status Summary Screen Hdsl / HDSL2 Status ScreenLoss Shelf Controller Options Performance Data ScreenPerformance History Screen Alarm Status Screen Alarm History ScreenLoopback Status Summary Screen Loopback OptionsTroubleshooting Screen Self-Test Options Screen 61221051L1-5A 61221051L1-5, Issue Self-Test Options ScreenProvisioning Screen 61221051L1-5, Issue 61221051L1-5A Provisioning Summary ScreenProtection Configuration Screen Protection Screen MainSpecifications MaintenanceWarranty and Customer Service