6. MAINTENANCE

The ADTRAN E220 HFAC requires no routine maintenance to operate properly.

ADTRAN recommends that major repairs on the shelf not be performed in the field. Repair services may be obtained by returning defective units to

ADTRAN.

7. SPECIFICATIONS

Table 8 lists E220 HFAC specifications.

Table 8. E220 HFAC Specifications

 

Power

-48 VDC @ 60 mA (maximum)

 

 

 

Physical

Dimensions:

5.6" high x 1.25" wide x 10.1" deep

Weight:

< 1 pound

 

 

 

Temperature

Operating:

-40°C to +70° C

Storage:

-40°C to +85° C

 

 

 

Part Number

ADTRAN E220

 

Shelf Plug in,

 

Single slot

1221051L1

 

 

8. WARRANTY AND CUSTOMER SERVICE

ADTRAN will replace or repair this product within 10 years from the date of shipment if it does not meet its published specifications or fails while in service (see ADTRAN Carrier Network Equipment Warranty, Repair, and Return Policy and Procedure, document 60000087-10A).

Contact Customer and Product Service (CAPS) prior to returning equipment to ADTRAN.

For service, CAPS requests, or further information, contact one of the following numbers:

Part Number

1221051L1

ADTRAN Sales

Pricing/Availability (800) 827-0807

ADTRAN Technical Support

Presales Applications/Postsales Technical Assistance (888) 4-ADTRAN

Standard hours: Monday-Friday, 7 a.m. - 7 p.m. CST

Emergency hours: 7 days/week, 24 hours/day

ADTRAN Repair/CAPS

Return for Repair/Upgrade (256) 963-8722

Repair and Return Address

ADTRAN, Inc.

CAPS

901 Explorer Boulevard

Huntsville, Alabama 35806-2807

20

61221051L1-5, Issue 1

61221051L1-5A

Image 20
Contents L1-5A Issue 1, April Clei # T1L4FFCCGeneral Revision HistoryInstallation ConfigurationElectrical cable compliance Shelf AddressErrored Seconds ES Alarm S1 Switch Options arrow indicates default setting61221051L1-5A 61221051L1-5, Issue Unit Options61221051L1-5, Issue 61221051L1-5A S2 Switch Options arrow indicates default settingS3 Switch Options arrow indicates default setting Hfac Alarm Outputs Severely Errored Seconds SES AlarmUnavailable Seconds UAS Alarm HTU-C Fuse Alarm AlarmsHfac Fuse Alarm ConnectionsFaceplate Features Hfac Faceplate FeaturesControl Port Operation Screen AbbreviationsScreen Abbreviations Main MenuIntroductory Menu Shelf Status Summary Screen Hdsl / HDSL2 Status ScreenLoss Shelf Controller Options Performance Data ScreenPerformance History Screen Alarm Status Screen Alarm History ScreenLoopback Status Summary Screen Loopback OptionsTroubleshooting Screen Self-Test Options Screen 61221051L1-5A 61221051L1-5, Issue Self-Test Options ScreenProvisioning Screen 61221051L1-5, Issue 61221051L1-5A Provisioning Summary ScreenProtection Configuration Screen Protection Screen MainWarranty and Customer Service MaintenanceSpecifications