ADTRAN E220 HFAC HDSL2 specifications Loopback Status Summary Screen, Loopback Options

Page 15

Loopback Status Summary Screen

Item selection 4, Loopback Control, from the Main Menu displays the loopback status information for all of the HTU-C, HRE, and HTU-R units monitored by the HFAC. Loopback Status (On, Off, or Not available) is presented for loopbacks to both the network and the customer at both the HTU-C, HRE, and HTU-R. Figure 16 illustrates the Loopback Status Summary Screen.

Loopback Options

By pressing a slot number followed by an S from the

Loopback Status Summary Screen, you will be presented with a slot-specific Loopback Options Screen (Figure 17). Multiple loopbacks can be initiated for each circuit. This screen graphically depicts the loopback activated by showing through reverse video, the path of the loopback and the locations it loops to. Also, the status indication changes from inactive to active. The initiation of a loopback is accomplished by pressing the corresponding number of the loopback desired, followed by an L.

11/23/99 00:19:57

 

LOOPBACK STATUS

 

SHELF ADDRESS = 00

 

 

 

HTU-C

HRE1

HRE2

 

HTU-R

 

 

<--

-->

<--

<--

<--

-->

SLOT#

NET

CUST

NET

NET

NET

CUST

-----

-------------

----

----

-------------

1

:

---

---

----

----

----

----

2

:

OFF

OFF

xxxx

xxxx

OFF

OFF

3

:

OFF

OFF

xxxx

xxxx

OFF

OFF

4

:

OFF

OFF

OFF

xxxx

OFF

OFF

5

:

OFF

OFF

xxxx

xxxx

OFF

OFF

6

:

---

---

----

----

----

----

7

:

OFF

OFF

xxxx

xxxx

OFF

OFF

8

:

OFF

OFF

OFF

OFF

OFF

OFF

9

:

OFF

OFF

xxxx

xxxx

OFF

OFF

10

:

OFF

OFF

xxxx

xxxx

OFF

OFF

11

:

OFF

OFF

xxxx

xxxx

OFF

OFF

12

:

OFF

OFF

xxxx

xxxx

OFF

OFF

13

:

OFF

OFF

xxxx

xxxx

OFF

OFF

ON

=

LOOPBACK

ON

 

 

 

 

OFF

=

LOOPBACK

OFF

PRESS “nnS”

-

Slot

Select,

xxxx

=

NOT AVAILABLE

“M”

-

Main

Menu :

----

=

EMPTY SLOT

 

 

 

 

Figure 16. Loopback Status Summary Screen

11/23/99 00:21:48

 

LOOPBACK OPTIONS

[ SLOT = 8

 

]

 

 

SHELF ADDRESS = 00

 

_____

 

 

_____

 

_____

 

 

_____

 

 

 

HTU-C

HRE 1

HRE 2

 

HTU-R

 

 

 

 

 

 

 

 

LP1

LP1

LP1

 

 

 

—>

 

<===>

<===>

<===><--,

<—-

 

 

 

 

 

NET

 

 

CUST

 

 

LP2

LP2

LP2

 

 

<—

 

<===>

<===>

<===><--,

—>

 

 

 

 

 

 

 

 

 

 

 

_____

_____

_____

 

_____

 

 

1) LOOPBACK TO NETWORK

 

AT HTU-C =

UNAVAILABLE

 

2) LOOPBACK TO CUSTOMER

 

AT HTU-C =

UNAVAILABLE

 

3) LOOPBACK TO NETWORK

 

AT HTU-R =

ACTIVE

 

 

 

4) LOOPBACK TO CUSTOMER

 

AT HTU-R =

UNAVAILABLE

 

5) LOOPBACK TO NETWORK

 

AT HRE1

=

UNAVAILABLE

 

6) LOOPBACK TO NETWORK

 

AT HRE2

=

UNAVAILABLE

Press

“nL”

-

 

Toggle Loopback(ex. 3L),

 

“nnS”

-

Select Slot,

 

“P”

-

 

Previous Screen,

 

“M” -

Main Menu

:

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 17. Loopback Options Screen

61221051L1-5A

61221051L1-5, Issue 1

15

Image 15
Contents Revision History L1-5A Issue 1, AprilClei # T1L4FFCC GeneralShelf Address InstallationConfiguration Electrical cable complianceUnit Options Errored Seconds ES AlarmS1 Switch Options arrow indicates default setting 61221051L1-5A 61221051L1-5, IssueS2 Switch Options arrow indicates default setting S3 Switch Options arrow indicates default setting61221051L1-5, Issue 61221051L1-5A Severely Errored Seconds SES Alarm Unavailable Seconds UAS AlarmHfac Alarm Outputs Connections HTU-C Fuse AlarmAlarms Hfac Fuse AlarmScreen Abbreviations Faceplate FeaturesHfac Faceplate Features Control Port OperationMain Menu Screen AbbreviationsIntroductory Menu Hdsl / HDSL2 Status Screen Shelf Status Summary ScreenLoss Performance Data Screen Shelf Controller OptionsPerformance History Screen Alarm History Screen Alarm Status ScreenLoopback Options Loopback Status Summary ScreenTroubleshooting Screen Self-Test Options Screen Self-Test Options Screen 61221051L1-5A 61221051L1-5, IssueProvisioning Summary Screen Provisioning Screen 61221051L1-5, Issue 61221051L1-5AProtection Screen Main Protection Configuration ScreenMaintenance SpecificationsWarranty and Customer Service