ADTRAN E220 HFAC HDSL2 Installation, Electrical cable compliance, Configuration, Shelf Address

Page 2

The HFAC supports the HTU-Cs / H2TU-Cs listed below.

¥

1242024L1

¥

1242002L7

¥

1242002L2

¥

1242029L1

¥

1242002L5

¥

1242029L2

¥

1242002L6

¥

1244001L1

¥

1245001L2

¥

1246001L2

¥

1245001L9

¥

1221001L2

¥

1245011L1

 

 

The differences in functionality when working with list-specific HTU-Cs / H2TU-Cs or HREs / H2Rs, if any, are called out in this practice. Also, the HFAC has necessary interface software for communications with the HCOT-CTL (ADTRAN p/n: 1240009L1, 1244051L1, 1221051L1). See appropriate HCOT practices for installation and maintenance information.

The HFAC collects and presents performance information for each circuit deployed in the shelf. It also allows control of all provisioning information for each circuit. The unit can also be configured to provide advanced alarm processing features.

2. INSTALLATION

C A U T I O N !

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.

After unpacking the unit, inspect it for damage. If damage is discovered, file a claim with the carrier, then contact ADTRAN. See Warranty and Customer Service.

Electrical cable compliance

Table 1 shows the Compliance Codes for HFAC. The HFAC complies with the requirements covered under UL 1950 third edition and is intended to be installed in an enclosure with an Installation Code (IC) of ÒBÓ or ÒE.Ó

NOTE

This product is intended for installation in Restricted Access Locations Only. Input current at maximum load is 1A at -48 VDC. Maximum output at overcurrent condition is 165 mA at -190 VDC.

Table 1. Compliance Codes

Code Input Output

IC A -

TC - -

PC F C

Configuration

Operation of the HFAC is influenced by three sets of configuration option switches (see Figures 2 and 3).

Shelf Address

Two rotary switches (U38 and U39) are provided to program the shelfÕs address. In a system where several shelves are under the common control of one ADTRAN E220 HCOT-CTL System Controller, each individual shelf must be programmed with a unique shelf address. Addresses range from 00 to 99. In a system that does not utilize the HCOT-CTL System Controller, the shelf address is not used. To program

Shelf Address Select Switches

(Default = 00)

S2 S1

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

Up

Ones

7

8

9

6

0

5

4

1

3

2

Tens

7

8

9

6

0

5

4

1

3

2

Faceplate

Figure 2. Configuration and Shelf Address Switches

2

61221051L1-5, Issue 1

61221051L1-5A

Image 2
Contents General L1-5A Issue 1, AprilClei # T1L4FFCC Revision HistoryElectrical cable compliance InstallationConfiguration Shelf Address61221051L1-5A 61221051L1-5, Issue Errored Seconds ES AlarmS1 Switch Options arrow indicates default setting Unit Options61221051L1-5, Issue 61221051L1-5A S2 Switch Options arrow indicates default settingS3 Switch Options arrow indicates default setting Hfac Alarm Outputs Severely Errored Seconds SES AlarmUnavailable Seconds UAS Alarm Hfac Fuse Alarm HTU-C Fuse AlarmAlarms ConnectionsControl Port Operation Faceplate FeaturesHfac Faceplate Features Screen AbbreviationsScreen Abbreviations Main MenuIntroductory Menu Shelf Status Summary Screen Hdsl / HDSL2 Status ScreenLoss Shelf Controller Options Performance Data ScreenPerformance History Screen Alarm Status Screen Alarm History ScreenLoopback Status Summary Screen Loopback OptionsTroubleshooting Screen Self-Test Options Screen 61221051L1-5A 61221051L1-5, Issue Self-Test Options ScreenProvisioning Screen 61221051L1-5, Issue 61221051L1-5A Provisioning Summary ScreenProtection Configuration Screen Protection Screen MainWarranty and Customer Service MaintenanceSpecifications