ADTRAN E220 HFAC HDSL2 specifications Provisioning Summary Screen

Page 18

Provisioning Summary Screen

Selection of item 8 from the Main Menu supplies provisioning information on individual circuits being accessed by the HFAC. Figure 20 is a slot-specific provisioning screen showing the provision option item, current settings, and hardware settings for that particular circuit. A key at the bottom of the screen describes the options associated with this screen.

Menu item 7 provides a means of provisioning specific HTU-C units, from the HFAC, to enable or disable various HTU-C alarms. This option is different from the Disable Alarms option on the HFAC Options Setup screen. This option sets the selected HTU-C to enable or disable the alarms presented on the HTU-C edge connector pins 20 and 21 (closure between pins) and edge connector pin 1 (closure to ground).

The Enable All selection permits alarms to be presented on the aforementioned edge connector pins

due to faults at any of the HDSL / HDSL2 loop, DSX- 1, or DS1 locations. The Disable All disables all alarms due to external faults or faults within the HDSL / HDSL2 equipment or loops.

The Disable EXT selection allows only alarms caused by faults in the HDSL / HDSL2 equipment or HDSL / HDSL2 loops and suppresses alarms caused by external DSX-1 or DS1 faults.

NOTE

ADTRAN 220/E220 H2TU-Cs support an EXTERNAL LBO option for use in legacy 220 ORB shelves. The ADTRAN E220 shelf doesnotrequiretheEXTERNALLBOoption. The E220 HFAC will not allow the selection of the EXTERNAL LBO setting when initiated through the HFAC terminal screen. It should be noted that the HFAC will not automatically override an EXTERNAL LBO setting.

11/23/99

00:28:34

PROVISIONING

[ SLOT = 8

]

SHELF ADDRESS = 00

___________________________________________________ ______________________

 

 

 

 

 

 

 

 

 

PROVISIONS

 

 

CURRENT SETTINGS

HARDWARE SETTINGS

-----------------------

 

----------------

-----------------

1.

DSX-1 LINE BUILDOUT

=

 

399-533 FEET

399-533 FEET

2.

DSX-1/DS1 LINE CODE

=

 

B8ZS

B8ZS

3.

DSX-1/DS1 FRAMING

=

 

ESF

ESF

4.

LOOPBACK TIMEOUT

=

 

NONE

NONE

5.

DS1 OUTPUT LEVEL

=

 

-15 dB

-15 dB

6.

NIU LOOPBACK

=

 

DISABLED

DISABLED

7.

DS0 BLOCKING

 

 

 

 

 

 

 

 

 

 

 

 

 

00000000 00000000 00000000

 

 

CHANNELS

1

 

 

24

 

 

 

“X” BLOCKS

THE CHANNEL.

 

_________________________________________________________________________

Press : “nP”

to change

corresponding provision

(ex. 5P)

“H”

to

copy hardware

settings

to

current settings

“I”

to

implement and

save current setting changes

“nnS”

select slot,

“M”

main

menu

 

 

 

->

<-

 

 

 

 

Figure 20. Provisioning Screen

18

61221051L1-5, Issue 1

61221051L1-5A

Image 18
Contents General L1-5A Issue 1, AprilClei # T1L4FFCC Revision HistoryElectrical cable compliance InstallationConfiguration Shelf Address61221051L1-5A 61221051L1-5, Issue Errored Seconds ES AlarmS1 Switch Options arrow indicates default setting Unit OptionsS2 Switch Options arrow indicates default setting S3 Switch Options arrow indicates default setting61221051L1-5, Issue 61221051L1-5A Severely Errored Seconds SES Alarm Unavailable Seconds UAS AlarmHfac Alarm Outputs Hfac Fuse Alarm HTU-C Fuse AlarmAlarms ConnectionsControl Port Operation Faceplate FeaturesHfac Faceplate Features Screen AbbreviationsScreen Abbreviations Main MenuIntroductory Menu Shelf Status Summary Screen Hdsl / HDSL2 Status ScreenLoss Shelf Controller Options Performance Data ScreenPerformance History Screen Alarm Status Screen Alarm History ScreenLoopback Status Summary Screen Loopback OptionsTroubleshooting Screen Self-Test Options Screen 61221051L1-5A 61221051L1-5, Issue Self-Test Options ScreenProvisioning Screen 61221051L1-5, Issue 61221051L1-5A Provisioning Summary ScreenProtection Configuration Screen Protection Screen MainMaintenance SpecificationsWarranty and Customer Service