Registering computers (edit computer list)

To create/edit computer entries

1Display the Configuration menu. Note: You must be logged-in as the ADMIN user.

2Highlight ‘Edit Computer List’ and press .

ADDERVIEW CATx 1000

Edit Computer List

 

Computer 1

01

Computer 2

02

Computer 3

03

Computer 4

04

Computer 5

05

Computer 6

06

Computer 7

12

Computer 8

0803

Ins-Add

Del-Delete

F1-Clone

Enter-Edit

-Select

F3-Find

Esc-Quit

 

3Either:

Create a new computer entry – Press and enter a new name, or

Edit an existing computer entry – Highlight a computer name and press

. Press (Backspace) to delete existing characters and enter the required new name (up to 16 characters).

Note: Avoid creating two names for the same computer port.

4Press and the cursor will move to the computer port column on the right side. Change or enter the port address of the computer as required. See the Addressing computers in a cascade section for more details.

5When the port address is complete, press . The ‘Edit access rights’ menu will be displayed.

ADDERVIEW CATx 1000

Edit access rights

 

Cross markers indicate which

admin

+

users will be granted access to

Sam

+

the currently selected computer.

Oliver

+

To change the permission state:

Johnny

 

 

Highlight a user name and press the

space bar.

Space-Toggle Enter-Save

F1-AllF2-None

F3-Find

Esc-Quit

Here you can determine which users should have access to the created/ edited computer. Only users that show a ‘+’ marker to the right of the menu box will be granted access to the computer.

Note: Access rights for particular user accounts to computers can also be controlled from the ‘Edit User List’ menu

6Select and deselect users as follows:

Individual user - Highlight a user name, then press to apply, or remove, the ‘+’ marker.

Allow access for all users – Press

Allow no user access (except ADMIN) – Press

6When all settings have been made, press to save and exit. Press to return to the ‘Configuration Menu’.

   



22

Image 23
Contents AdderView CATx Contents Further information Introduction Remote user port AdderView CATx 1000 features front and rearWhat you may additionally need What’s in the boxDouble unit rack brackets MountingSingle unit rack brackets Connections CAM Computer Power System SwitchTo connect the local user port Local userTo connect a remote user Cable lengths for remote user locationsTo connect a computer system Computer system via CAMTo connect the power supply Power in connectionSwitch Power control portTo connect and address the switch boxes See also Cascading multiple unitsTo connect units in cascade Tips for successful cascadingAddressing computers in a cascade Slave AdderView CATx Multiple video head connectionsHost computer port/channel Video off Remote switching controlOverall initial configuration ConfigurationTo access the configuration menu Configuration menusTo set an Admin password General security and configuration stepsConfiguration menus layout To enable general securityTo create/edit user accounts Access to all computers Press Access to no computers PressRegistering users edit user list To create/edit computer entries Registering computers edit computer listIf the image controls cannot provide a crisp image Video compensationRemote user video compensation To display a suitable high contrast imageTo autoset sharpness X100 modules only Press Remote user skew adjustmentTo apply remote user video compensation Creating a skew test pattern To use skew adjustmentUsing the supplied skew pattern To define an autoscan list To select an autoscan modeAutoscanning To select an autoscan periodTo transfer configuration settings Saving and restoring configuration settingsHints for editing To edit the configuration settingsTo clear a password and restore factory default settings What to do if the Admin password has been forgottenTo control two or more ports simultaneously Power switching configurationPower control sequences To configure the power sequences for each host computerTo use the KVM Firmware Uploader utility Performing upgradesItems required to use the upgrade utility Upgrading AdderView CATx 1000 units and CAMsIssues to consider when performing flash upgrades Selecting a computer Local and remote user accessTo gain access as a local or remote user To select a computer using hotkeysSelection Menu here you can select computers by name To select a computer using the on-screen menuStandard hotkeys User arbitration simultaneous local and remote users To select a computer using mouse buttonsTo select a computer using mouse buttons Advanced method To log out from the AdderView CATx Logging in and outSelecting cascaded computers To log in to the AdderView CATxReminder banner To enable/disable the confirmation boxTo change banner colours or disable the banner Confirmation boxUser preferences and functions Power switching via configuration menuTo switch a computer on or off US +1 888 275 Getting assistanceTo access the configuration menus Appendix 1 Configuration menusFunctions User Preferences Screen Saver Mouse SwitchingAutoscan Mode Global PreferencesOSD Dwell Time Settings 1, 2, 3, 5, 10 SecondsUser Timeout Settings 1, 2, 5, 10, 30 SECONDS, 1, 5, 10 MinutesSetup Options Format DDC Source Settings AUTO, LOCAL, REMOTE, DefaultDDC Refresh Settings AT START, Disabled Advanced OptionsUSB Country Code Country Code Settings AUTO, MANUAL, DisabledDefault Country Power switch to power switch daisy chain cable Appendix 2 Cable and connector specificationsAdderView CATx 1000 to power switch cable Safety information WarrantyCanadian Department of Communications RFI statement Radio Frequency EnergyEuropean EMC directive 89/336/EEC FCC Compliance Statement United StatesHoe Huat Industrial Building Index 