Adder Technology 1000 manual Introduction

Page 4

Introduction

Thank you for choosing the AdderView CATx 1000 from Adder Technology. This compact unit has been created to allow a single operator to take full control of many computer systems.

Like the other models within the highly successful AdderView CATx family, this unit takes full advantage of category 5, 5e or 6 structured cabling to provide flexible installation and configuration. Every connected computer can be up to 10m (32 feet) from the AdderView CATx 1000, linked by a standard CATx cable and the ingenious CAM (Computer Access Module).

The AdderView CATx 1000 is available in two sizes, directly supporting eight or sixteen computers respectively. These numbers can be increased at any time thanks to the ability to connect other AdderView CATx 1000 units in cascade to provide a much larger network of controlled computers. Both models provide full enterprise level security to restrict access to authorised personnel.

Optional power switch control allows you to remotely perform a hard reset on any host system, no matter how badly it has locked up.

The user console can be either connected directly to the Adderview CATx 1000 unit or placed up to 300m (980 feet) away using either Adder X100 or X200 extenders and, once again, standard CATx cabling. In addition to providing the usual keyboard, video and mouse signals, the AdderView CATx 1000 also provides audio output for full feedback where necessary.

 

Remote user

A remote user can be linked, via an Adder X100 or X200 extender and category 5, 5e or 6 cabling, to a maximum distance of 300m (980 ft).

Local user One user can be connected directly to the AdderView CATx 1000.

X100 X200

}

LOC REM OSD UPG LCK PWR

KVM

only

www.adder.com

Dual users

When both a local and a remote user are connected, both consoles will see the same output, however, only one will be able to take control at any one time. Control is automatically relinquished by the current user two seconds after the last input action, whereupon either user can gain control. The control status is signified by the keyboard indicators at each console.

 

Many computers

AdderView CATx 1000 units can directly support either 8 or 16 computer systems. Multiple AdderView CATx 1000 units can also be cascaded to support a maximum of 256 computers.

Each system is linked using a Computer Access Module (CAM) and category 5, 5e or 6 cabling to a maximum distance of 10m

(32 ft) from the AdderView CATx 1000 unit.

CAM CAM CAM CAM CAM CAM

CAM formats

The CAMs are available in different formats to support all common types of systems, which can easily be mixed within a multi-format configuration.

Power switch

Optional power control You have the opportunity to attach one or more power switches. These control the supply to the system(s) and allow a remote user to hard reset any system that has suffered a failure.

Represents Video, USB keyboard/mouse & audio connections

Represents Video,

}PS/2 keyboard/mouse & audio connections





Image 4
Contents AdderView CATx Contents Further information Introduction AdderView CATx 1000 features front and rear Remote user portWhat’s in the box What you may additionally needSingle unit rack brackets MountingDouble unit rack brackets CAM Computer Power System Switch ConnectionsLocal user To connect the local user portCable lengths for remote user locations To connect a remote userComputer system via CAM To connect a computer systemPower in connection To connect the power supplyTo connect and address the switch boxes Power control portSwitch Cascading multiple units See alsoTips for successful cascading To connect units in cascadeAddressing computers in a cascade Multiple video head connections Slave AdderView CATxRemote switching control Host computer port/channel Video offConfiguration Overall initial configurationConfiguration menus To access the configuration menuGeneral security and configuration steps Configuration menus layoutTo enable general security To set an Admin passwordRegistering users edit user list Access to all computers Press Access to no computers PressTo create/edit user accounts Registering computers edit computer list To create/edit computer entriesVideo compensation Remote user video compensationTo display a suitable high contrast image If the image controls cannot provide a crisp imageTo apply remote user video compensation Remote user skew adjustmentTo autoset sharpness X100 modules only Press Using the supplied skew pattern To use skew adjustmentCreating a skew test pattern To select an autoscan mode AutoscanningTo select an autoscan period To define an autoscan listSaving and restoring configuration settings To transfer configuration settingsTo edit the configuration settings Hints for editingWhat to do if the Admin password has been forgotten To clear a password and restore factory default settingsPower switching configuration Power control sequencesTo configure the power sequences for each host computer To control two or more ports simultaneouslyPerforming upgrades Items required to use the upgrade utilityUpgrading AdderView CATx 1000 units and CAMs To use the KVM Firmware Uploader utilityIssues to consider when performing flash upgrades Local and remote user access To gain access as a local or remote userTo select a computer using hotkeys Selecting a computerStandard hotkeys To select a computer using the on-screen menuSelection Menu here you can select computers by name To select a computer using mouse buttons Advanced method To select a computer using mouse buttonsUser arbitration simultaneous local and remote users Logging in and out Selecting cascaded computersTo log in to the AdderView CATx To log out from the AdderView CATxTo enable/disable the confirmation box To change banner colours or disable the bannerConfirmation box Reminder bannerTo switch a computer on or off Power switching via configuration menuUser preferences and functions Getting assistance US +1 888 275Appendix 1 Configuration menus To access the configuration menusFunctions User Preferences Mouse Switching Autoscan ModeGlobal Preferences Screen SaverSettings 1, 2, 3, 5, 10 Seconds User TimeoutSettings 1, 2, 5, 10, 30 SECONDS, 1, 5, 10 Minutes OSD Dwell TimeSetup Options DDC Source Settings AUTO, LOCAL, REMOTE, Default DDC Refresh Settings AT START, DisabledAdvanced Options FormatDefault Country Country Code Settings AUTO, MANUAL, DisabledUSB Country Code AdderView CATx 1000 to power switch cable Appendix 2 Cable and connector specificationsPower switch to power switch daisy chain cable Warranty Safety informationRadio Frequency Energy European EMC directive 89/336/EECFCC Compliance Statement United States Canadian Department of Communications RFI statementHoe Huat Industrial Building Index 