Adder Technology 1000 manual What to do if the Admin password has been forgotten

Page 30

What to do if the ADMIN password has been forgotten

If the ADMIN password becomes mislaid or forgotten, you will not be able to access the AdderView CATx 1000 to add or edit users and computer names. This situation may be resolved by performing a complete reset to return the AdderView CATx 1000.

IMPORTANT: A complete reset erases all the user names and computer names that you have setup.

To clear a password (and restore factory default settings)

1Remove power from the AdderView CATx 1000 unit.

2Connect the AdderView CATx 1000 unit to a computer in the same manner as you would to carry out a flash upgrade - see Performing flash upgrades.

3Press and hold the reset button on the front panel (requires paper clip or similar).

4Apply power and after 3 seconds release the reset button. The ‘UPG’ LED should now be iluminated.

5Set the computer serial settings to the following: 57600, n, 8, 1

6Using ‘TeraTerm’ (recommended) or an alternative terminal program, send “CLEAR<cr>” - in upper case from the keyboard. The AdderView CATx 1000 unit should respond with “OK”.

7The password is now clear and all factory default settings restored.

   



29

Image 30
Contents AdderView CATx Contents Further information Introduction AdderView CATx 1000 features front and rear Remote user portWhat’s in the box What you may additionally needMounting Single unit rack bracketsDouble unit rack brackets CAM Computer Power System Switch ConnectionsLocal user To connect the local user portCable lengths for remote user locations To connect a remote userComputer system via CAM To connect a computer systemPower in connection To connect the power supplyPower control port To connect and address the switch boxesSwitch Cascading multiple units See alsoTips for successful cascading To connect units in cascadeAddressing computers in a cascade Multiple video head connections Slave AdderView CATxRemote switching control Host computer port/channel Video offConfiguration Overall initial configurationConfiguration menus To access the configuration menuTo enable general security General security and configuration stepsConfiguration menus layout To set an Admin passwordAccess to all computers Press Access to no computers Press Registering users edit user listTo create/edit user accounts Registering computers edit computer list To create/edit computer entriesTo display a suitable high contrast image Video compensationRemote user video compensation If the image controls cannot provide a crisp imageRemote user skew adjustment To apply remote user video compensationTo autoset sharpness X100 modules only Press To use skew adjustment Using the supplied skew patternCreating a skew test pattern To select an autoscan period To select an autoscan mode Autoscanning To define an autoscan listSaving and restoring configuration settings To transfer configuration settingsTo edit the configuration settings Hints for editingWhat to do if the Admin password has been forgotten To clear a password and restore factory default settingsTo configure the power sequences for each host computer Power switching configurationPower control sequences To control two or more ports simultaneouslyUpgrading AdderView CATx 1000 units and CAMs Performing upgradesItems required to use the upgrade utility To use the KVM Firmware Uploader utilityIssues to consider when performing flash upgrades To select a computer using hotkeys Local and remote user accessTo gain access as a local or remote user Selecting a computerTo select a computer using the on-screen menu Standard hotkeysSelection Menu here you can select computers by name To select a computer using mouse buttons To select a computer using mouse buttons Advanced methodUser arbitration simultaneous local and remote users To log in to the AdderView CATx Logging in and outSelecting cascaded computers To log out from the AdderView CATxConfirmation box To enable/disable the confirmation boxTo change banner colours or disable the banner Reminder bannerPower switching via configuration menu To switch a computer on or offUser preferences and functions Getting assistance US +1 888 275Appendix 1 Configuration menus To access the configuration menusFunctions User Preferences Global Preferences Mouse SwitchingAutoscan Mode Screen SaverSettings 1, 2, 5, 10, 30 SECONDS, 1, 5, 10 Minutes Settings 1, 2, 3, 5, 10 SecondsUser Timeout OSD Dwell TimeSetup Options Advanced Options DDC Source Settings AUTO, LOCAL, REMOTE, DefaultDDC Refresh Settings AT START, Disabled FormatCountry Code Settings AUTO, MANUAL, Disabled Default CountryUSB Country Code Appendix 2 Cable and connector specifications AdderView CATx 1000 to power switch cablePower switch to power switch daisy chain cable Warranty Safety informationFCC Compliance Statement United States Radio Frequency EnergyEuropean EMC directive 89/336/EEC Canadian Department of Communications RFI statementHoe Huat Industrial Building Index 