Extron electronic 68-1021-01 user manual Connection and Configuration Connecting the Hardware

Page 12

Connection and Configuration

Connecting the Hardware

The IPL M PDP-ES interface card is housed inside of an expansion slot (namely, the ES Card Slot) of a fourth generation Pioneer plasma. Figure 3-1 illustrates a typical setup.

Extron

IPL M PDP-ES

Pioneer Plasma Ethernet Card

 

 

RS-232

 

 

RESET

IPL M PDP-ES

ACT

LINK

LAN

 

 

RS-232

 

LAN

VCR

DVD

Laptop

MLC 206

Extron

MLC 206

MediaLink Controller

PC

Figure 3-1 — IPL M PDP-ES interface connections

Direct PC connection

This type of connection is used initially to connect to and configure the IPL M PDP-ES card.

1.Plug one end of a Cat 5, crossover Ethernet cable into the rear panel Ethernet connector of the IPL M PDP-ES interface card. Refer to figure 2-7 for RJ-45 connector wiring.

2.Plug the other end of the Ethernet cable into the Ethernet port on your PC.

Ethernet/LAN port

This type of connection is used on an ongoing basis to connect the IPL M PDP-ES interface card to a LAN for remote control of the Pioneer plasma and other connected devices.

1.Plug one end of a Cat 5, straight-through Ethernet cable into the LAN port of the IPL M PDP-ES interface card. Refer to figure 2-7 for RJ-45 connector wiring.

2.Plug the other end of the Ethernet cable into a network switch, hub, or router connected to an Ethernet LAN or to the Internet.

3.Ensure that your PC is connected to the network switch, hub, or router.

RS-232 port

The IPL M PDP-ES can be connected to a controller device or a local PC through its RS-232 port.

PC connection

1.Connect one end of a straight-through serial cable (Extron part #26-433-03) to the RS-232 port of the interface card. Refer to figure 2-8 for pin assignments.

2.Connect the other end of the cable to a local PC.

Serial connection

1.Connect the male end of an RS-232 cable (Extron part#

26-437-04) to the RS-232 port of the interface card. Refer to figure 2-8 for pin assignments.

2.Connect the bare end of the cable to a controller device, such as the MLC 206, using the termination illustrated below.

ATransmit (Tx) Orange

B

Receive (Rx) Red

 

To the

 

 

 

 

 

Pioneer plasma’s

 

 

 

 

 

E

Ground (

 

) Green

 

RS-232 port

 

 

 

 

 

 

MLC

Display/Source Control port (RS-232)

A B C D E

RS-232

Figure 3-2 — Controller device wiring

Configuring the Hardware

To function together properly, both the controlling PC and the IPL M PDP-ES interface card must be configured correctly: the PC must be network-capable, with the proper protocols installed and the hardware configured correctly.

PC configuration

This manual assumes that you have a Windows PC equipped with an operating network adapter. To allow your PC to work with Extron’s Ethernet-controlled products, the TCP/IP protocol must be installed and properly configured.

To use the IPL M PDP-ES on an existing Ethernet LAN intranet, your network administrator can provide you with a unique IP address or confirm whether you need to set up the

3-2

IPL M PDP-ES • Connection and Configuration

IPL M PDP-ES • Connection and Configuration

3-3

Image 12
Contents User’s Manual IP Link ToolsPrecautions Extron’s WarrantyFCC Class a Notice Quick Start Guide IPL M PDP-ES Attach the network LAN cable to the LAN portTable of Contents Table of Contents, cont’d IntroductionFeatures IntroductionAbout this Manual About the IPL M PDP-ES Interface CardInstallation and Operation Introduction, cont’dInstallation and Operation Installation OverviewInstallation of the IPL M PDP-ES Interface Card Installing the Extron IPL M PDP-ES cardInstallation and Operation, cont’d Panel Features and CablingPower Ethernet/LAN communicationResetting the unit OperationRS-232 communication Connection and Configuration ThreeConnection and Configuration Connecting the Hardware Configuring the HardwareConnection and Configuration, cont’d IPL M PDP-ES interface card configurationConfiguring the IPL M PDP-ES using the ARP command Arp -s 10.13.170.15 00-05-A6-00-0A-90Configuring the IPL M PDP-ES using direct PC connection Configuring the IPL M PDP-ES using the RS-232 port192.168.254.253 Esc 10.13.170.15 CIFirmware upgrades Communication and ControlAccessing and using the Web server Navigating the default Web pagesCommunication and Control Communication with the Interface CardIP settings fields Port SettingsPasswords Communication and Control, cont’dEmail Alerts Firmware upgrade Sending an email alert through TelnetEsc 4 SM To add or update files File Management tabTo create a directory To delete unwanted files or directoriesPower Pioneer tabDisplay Status Display ControlsAdvanced Controls Energy Save ScheduleMonitor Using the command/response table Symbol definitionsPassword information Error responsesCopyright information PortData Bidirectional SerialFirmware Version/Part Number/Information IP Setup Commands Password and Security SettingsFile Commands Directories Re-map port designationsWeb Browser Specific Custom Web pages Telnet portTroubleshooting Direct access portSpecifications, Part Numbers, and Accessories Serial connectionsIf status is missing or unavailable, check the following Specifications PartsSpecifications, Part Numbers, Accessories, cont’d GlossaryGlossary GlossaryGlossary, cont’d Glossary, cont’d

68-1021-01 specifications

Extron's electronic 68-1021-01 is a versatile and advanced presentation switcher that caters to the growing demands of modern multimedia environments. This device is designed to simplify the process of connecting various audio and video sources to a single output, making it ideal for classrooms, boardrooms, and other professional settings where seamless presentations are essential.

One of the main features of the 68-1021-01 is its ability to handle multiple video formats. It supports HDMI, Composite Video, and RGB inputs, allowing users to connect a diverse range of devices, from laptops and document cameras to legacy equipment. This multi-format capability ensures that users can integrate their existing technology without the need for extensive upgrades.

The switcher's advanced signal processing technology contributes to optimal video quality. It features built-in scaling capabilities, which adjust the resolution of incoming signals to match the output requirements. This ensures that the image quality remains sharp and crisp, regardless of the source, minimizing potential degradation that can occur during format conversions.

Another notable aspect of the Extron 68-1021-01 is its user-friendly interface. It provides an intuitive control mechanism that can be customized to fit the operational preferences of the user. The device can be managed via button inputs, remote controls, or even through third-party control systems, offering flexibility in how users interact with the system.

In addition to video capabilities, the 68-1021-01 is equipped with robust audio management features. It integrates audio switching and processing, which allows users to manage audio signals from various sources seamlessly. This is particularly beneficial in environments where audio clarity is crucial, such as in presentations or video conferences.

The 68-1021-01 utilizes Extron's renowned EDID (Extended Display Identification Data) technology, which helps ensure compatibility between the source and display devices. This feature automatically communicates the display's capabilities, optimizing the connection to reduce the risk of resolution or formatting issues.

Finally, the build quality reflects Extron's commitment to durability and reliability. The device is designed for easy installation, with options for rack mounting or desktop use, and features robust connections to withstand everyday use in busy environments.

Overall, the Extron electronic 68-1021-01 stands out as an efficient and reliable presentation switcher that combines advanced technology with user-friendly design, making it a valuable addition to any modern audiovisual setup.