Extron electronic 68-1021-01 user manual Custom Web pages, Telnet port

Page 29

Communication and Control, cont’d

Pioneer Plasma A/V Device Control

Once the IPL M PDP-ES interface card is configured, control of A/V devices may be accomplished in several ways. These include Web pages, Telnet, and direct port access.

Response

URL Encoded (Web)

ASCII(Telnet)

Command

Pti 0*X69

W0 %2A X69 TC

 

TC

 

X69

 

Esc 0*

Port

port timeout

Ethernet Data

Set current conn

X69

W0TC

View current conn port timeout Esc 0TC

Pti 1*X69

W1 %2A X69 TC

Esc 1* X69 TC

Set global IP port timeout

X69

W1TC

Esc 1TC

View global IP port timeout

#####

Est

Ego

W1AE

W0AE

WAE

 

Esc 1AE

Esc 0AE

Esc AE

Event Control

Start Events 24 27

Stop Events 24 27

Query number of events running

Del•filename

Zpf

Zpx

Zpq

 

W filename EF

WZFFF

WZXXX

WZQQQ

 

 

 

 

 

 

 

 

 

 

= 255.255.0.0)

 

 

 

 

 

 

 

 

 

 

 

EF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Esc filename

Esc ZFFF

Esc ZXXX

Esc ZQQQ

subnet mask

Reset (ZAP)/Erase Commands

Erase user-supplied Web page/file24 28

Erase flash memory24

Reset all device settings to factory24

Absolute System Reset24

(Includes IP address = 192.168.254.254,

Custom Web pages

These pages can be either modified versions of the existing Web pages, or new Web pages developed in the field.

Web page development can be done with a Web site development tool such as FrontPage or Dreamweaver. Custom Web pages are loadable with the Web server File Manager (see File Management tab earlier in this chapter).

If you want one of the pages that you create and upload to be the default start-up page, name that file “index.html.”

Telnet (port 23)

Telnet, short for Telecommunications Network, provides a way for you to connect to a computer or server (in this case the

IPL M PDP-ES interface card) on a network. Once connected via Telnet, you can send ASCII commands (see the Command/ response table for Simple Instruction Set (SIS) commands earlier in this chapter) to the IPL M PDP-ES.

Accessing and using Telnet

1.From the Windows Start menu, Click Run, then enter “Telnet” and click OK. The Telnet program starts (see figure 4-18).

Figure 4-18 — Telnet command prompt

2.At the command prompt, enter “open” and press Enter.

4-28 IPL M PDP-ES • Communication and Control

IPL M PDP-ES • Communication and Control 4-29

Image 29
Contents IP Link Tools User’s ManualFCC Class a Notice PrecautionsExtron’s Warranty Attach the network LAN cable to the LAN port Quick Start Guide IPL M PDP-ESTable of Contents Introduction Table of Contents, cont’dIntroduction FeaturesAbout this Manual About the IPL M PDP-ES Interface CardIntroduction, cont’d Installation and OperationInstallation Overview Installation and OperationInstallation of the IPL M PDP-ES Interface Card Installing the Extron IPL M PDP-ES cardPanel Features and Cabling Installation and Operation, cont’dPower Ethernet/LAN communicationRS-232 communication Resetting the unitOperation Three Connection and ConfigurationConfiguring the Hardware Connection and Configuration Connecting the HardwareIPL M PDP-ES interface card configuration Connection and Configuration, cont’dConfiguring the IPL M PDP-ES using the ARP command Arp -s 10.13.170.15 00-05-A6-00-0A-90Configuring the IPL M PDP-ES using the RS-232 port Configuring the IPL M PDP-ES using direct PC connection192.168.254.253 Esc 10.13.170.15 CICommunication and Control Firmware upgradesNavigating the default Web pages Accessing and using the Web serverCommunication and Control Communication with the Interface CardPort Settings IP settings fieldsEmail Alerts PasswordsCommunication and Control, cont’d Esc 4 SM Firmware upgradeSending an email alert through Telnet File Management tab To add or update filesTo create a directory To delete unwanted files or directoriesPioneer tab PowerDisplay Status Display ControlsAdvanced Controls Monitor Energy SaveSchedule Symbol definitions Using the command/response tableCopyright information Password informationError responses Firmware Version/Part Number/Information PortDataBidirectional Serial File Commands IP Setup CommandsPassword and Security Settings Web Browser Specific DirectoriesRe-map port designations Telnet port Custom Web pagesDirect access port TroubleshootingIf status is missing or unavailable, check the following Specifications, Part Numbers, and AccessoriesSerial connections Parts SpecificationsGlossary Specifications, Part Numbers, Accessories, cont’dGlossary GlossaryGlossary, cont’d Glossary, cont’d

68-1021-01 specifications

Extron's electronic 68-1021-01 is a versatile and advanced presentation switcher that caters to the growing demands of modern multimedia environments. This device is designed to simplify the process of connecting various audio and video sources to a single output, making it ideal for classrooms, boardrooms, and other professional settings where seamless presentations are essential.

One of the main features of the 68-1021-01 is its ability to handle multiple video formats. It supports HDMI, Composite Video, and RGB inputs, allowing users to connect a diverse range of devices, from laptops and document cameras to legacy equipment. This multi-format capability ensures that users can integrate their existing technology without the need for extensive upgrades.

The switcher's advanced signal processing technology contributes to optimal video quality. It features built-in scaling capabilities, which adjust the resolution of incoming signals to match the output requirements. This ensures that the image quality remains sharp and crisp, regardless of the source, minimizing potential degradation that can occur during format conversions.

Another notable aspect of the Extron 68-1021-01 is its user-friendly interface. It provides an intuitive control mechanism that can be customized to fit the operational preferences of the user. The device can be managed via button inputs, remote controls, or even through third-party control systems, offering flexibility in how users interact with the system.

In addition to video capabilities, the 68-1021-01 is equipped with robust audio management features. It integrates audio switching and processing, which allows users to manage audio signals from various sources seamlessly. This is particularly beneficial in environments where audio clarity is crucial, such as in presentations or video conferences.

The 68-1021-01 utilizes Extron's renowned EDID (Extended Display Identification Data) technology, which helps ensure compatibility between the source and display devices. This feature automatically communicates the display's capabilities, optimizing the connection to reduce the risk of resolution or formatting issues.

Finally, the build quality reflects Extron's commitment to durability and reliability. The device is designed for easy installation, with options for rack mounting or desktop use, and features robust connections to withstand everyday use in busy environments.

Overall, the Extron electronic 68-1021-01 stands out as an efficient and reliable presentation switcher that combines advanced technology with user-friendly design, making it a valuable addition to any modern audiovisual setup.