Extron electronic 68-1021-01 Configuring the IPL M PDP-ES using direct PC connection, Ipi

Page 14

Connection and Configuration, cont’d

6.After verifying that the change was successful, issue the arp –d command at the DOS prompt. For example:

arp –d 10.13.170.15 removes 10.13.170.15 from the ARP table

or

arp –dremoves all static IP addresses from the ARP table.

Configuring the IPL M PDP-ES using direct PC connection

This type of connection is used to initially connect to and configure the IPL M PDP-ES interface card. You must change the card’s default settings (IP address, Subnet mask, and [optional] administrator password) in order to use the IPL M PDP-ES on an intranet (LAN) or on the Internet (WAN).

1.Plug one end of a Cat 5, crossover Ethernet cable into the LAN connector of the IPL M PDP-ES interface card. Refer to figure 2-7 for RJ-45 connector wiring.

2.Plug the other end of the Ethernet cable into the Ethernet port on your PC.

3.Right click on the Network Neighborhood or My Network Places icon on your Windows (98, 2000, NT, ME, or XP) desktop, and select Properties from the menu.

4.Right click Local Area Connection and select Properties from the menu.

5.Select Internet Protocol (TCP/IP) from the list and click on Properties again.

If Internet Protocol (TCP/IP) is not on the list, it must be added (installed). Refer to your Windows user’s manual or the online Help system for information on how to install the TCP/IP protocol.

6.Write down your current IP address and Subnet Mask below. If your PC is set to “Obtain an IP address automatically,” make a note of that, instead.

IP Address:

. . .

Subnet Mask:

. . .

7.Click on “Specify an IP address” or “Use the following IP address” (depending on your operating system), and leave the default gateway blank. Enter the following values:

IP address:

192.168.254.253

Subnet mask: 255.255.0.0

8.Save the changes and exit the Network setup. Reboot the PC, if required, for the changes to become effective.

9.Launch your Web browser (Internet Explorer), and type “http://192.168.254.254/” in the address box. The IPL M PDP-ES default Web page is displayed. Refer to Navigating the default Web pages, later in this chapter, for information on configuring your unit.

10.After configuring your IPL M PDP-ES, repeat steps 3 and 4, and change your TCP/IP settings back to their original configuration.

Configuring the IPL M PDP-ES using the RS-232 port

Using a straight cable, this type of connection can be used to initially connect to and configure the IPL M PDP-ES interface card.

1.Plug one end of a straight cable to the RS-232 port of the IPL M PDP-ES interface card and the other end to a PC. Refer to figure 2-8 for pin assignments.

2.Obtain a valid IP address for your IPL M PDP-ES card from your network administrator.

3.Run a communication program (such as HyperTerminal or DataViewer) accessed through the COM port.

4.Perform a mode 2 reset. See Resetting the unit in chapter 2 for detailed information on the reset modes.

5.Use the Set IP address command to set the IP address. For example, enter

Esc 10.13.170.15 CI

The unit should respond with

Ipi • 10.13.170.15

Refer to Command/Response Table for Simple Instruction Set (SIS) Commands in chapter 4 for more detailed information regarding the SIS commands.

6.Launch your Web browser (Internet Explorer), and type “http://10.13.170.15” in the address box.

The IPL M PDP-ES default Web page is displayed. Refer to Communication with the Interface Card in chapter 4 for information on accessing the Web server.

3-6

IPL M PDP-ES • Connection and Configuration

IPL M PDP-ES • Connection and Configuration

3-7

Image 14
Contents User’s Manual IP Link ToolsFCC Class a Notice PrecautionsExtron’s Warranty Quick Start Guide IPL M PDP-ES Attach the network LAN cable to the LAN portTable of Contents Table of Contents, cont’d IntroductionAbout this Manual FeaturesIntroduction About the IPL M PDP-ES Interface CardInstallation and Operation Introduction, cont’dInstallation of the IPL M PDP-ES Interface Card Installation and OperationInstallation Overview Installing the Extron IPL M PDP-ES cardPower Installation and Operation, cont’dPanel Features and Cabling Ethernet/LAN communicationRS-232 communication Resetting the unitOperation Connection and Configuration ThreeConnection and Configuration Connecting the Hardware Configuring the HardwareConfiguring the IPL M PDP-ES using the ARP command Connection and Configuration, cont’dIPL M PDP-ES interface card configuration Arp -s 10.13.170.15 00-05-A6-00-0A-90192.168.254.253 Configuring the IPL M PDP-ES using direct PC connectionConfiguring the IPL M PDP-ES using the RS-232 port Esc 10.13.170.15 CIFirmware upgrades Communication and ControlCommunication and Control Accessing and using the Web serverNavigating the default Web pages Communication with the Interface CardIP settings fields Port SettingsEmail Alerts PasswordsCommunication and Control, cont’d Esc 4 SM Firmware upgradeSending an email alert through Telnet To create a directory To add or update filesFile Management tab To delete unwanted files or directoriesDisplay Status PowerPioneer tab Display ControlsAdvanced Controls Monitor Energy SaveSchedule Using the command/response table Symbol definitionsCopyright information Password informationError responses Firmware Version/Part Number/Information PortDataBidirectional Serial File Commands IP Setup CommandsPassword and Security Settings Web Browser Specific DirectoriesRe-map port designations Custom Web pages Telnet portTroubleshooting Direct access portIf status is missing or unavailable, check the following Specifications, Part Numbers, and AccessoriesSerial connections Specifications PartsSpecifications, Part Numbers, Accessories, cont’d GlossaryGlossary GlossaryGlossary, cont’d Glossary, cont’d

68-1021-01 specifications

Extron's electronic 68-1021-01 is a versatile and advanced presentation switcher that caters to the growing demands of modern multimedia environments. This device is designed to simplify the process of connecting various audio and video sources to a single output, making it ideal for classrooms, boardrooms, and other professional settings where seamless presentations are essential.

One of the main features of the 68-1021-01 is its ability to handle multiple video formats. It supports HDMI, Composite Video, and RGB inputs, allowing users to connect a diverse range of devices, from laptops and document cameras to legacy equipment. This multi-format capability ensures that users can integrate their existing technology without the need for extensive upgrades.

The switcher's advanced signal processing technology contributes to optimal video quality. It features built-in scaling capabilities, which adjust the resolution of incoming signals to match the output requirements. This ensures that the image quality remains sharp and crisp, regardless of the source, minimizing potential degradation that can occur during format conversions.

Another notable aspect of the Extron 68-1021-01 is its user-friendly interface. It provides an intuitive control mechanism that can be customized to fit the operational preferences of the user. The device can be managed via button inputs, remote controls, or even through third-party control systems, offering flexibility in how users interact with the system.

In addition to video capabilities, the 68-1021-01 is equipped with robust audio management features. It integrates audio switching and processing, which allows users to manage audio signals from various sources seamlessly. This is particularly beneficial in environments where audio clarity is crucial, such as in presentations or video conferences.

The 68-1021-01 utilizes Extron's renowned EDID (Extended Display Identification Data) technology, which helps ensure compatibility between the source and display devices. This feature automatically communicates the display's capabilities, optimizing the connection to reduce the risk of resolution or formatting issues.

Finally, the build quality reflects Extron's commitment to durability and reliability. The device is designed for easy installation, with options for rack mounting or desktop use, and features robust connections to withstand everyday use in busy environments.