Extron electronic 68-1021-01 user manual Troubleshooting, Direct access port

Page 30

Communication and Control, cont’d

3.. At the < to > prompt, enter the IP address of the

IPL M PDP-ES. (The default IP address is 192.168.254.254, but it may have been changed in the setup or configuration process. If it was changed, use the new address.) Telnet defaults to port 23.

Figure 4-19 — Connecting to the IP address

4.If passwords were set up for the connected system, you are prompted to log in as an administrator or a user. Otherwise the system responds with a <cr/lf>.

5.Once you are connected, you can enter SIS commands as desired.

6.When you are finished entering commands to the interface, enter CTRL + to close the open connection.

7.Enter “quit” at the command prompt to quit Telnet.

Direct access (port 2001)

Direct access allows a direct, one-to-one connection to the plasma via a reserved IP port number. When a TCP session is initiated to port 2001, all data sent and received passes directly to and from that port without any processing.

Using direct access

1.Open a direct access Telnet session by entering the IP address followed by a space, then a port number 2001 (e.g., 192.168.244.244 2001).

2.Send Pioneer commands directly to the Pioneer plasma.

For specific functionality details and supported commands, refer to the Pioneer Plasma documentation.

3.Close the Telnet session to end the direct access session.

4.Use port redirect to finish the process. See the next section for detailed instructions.

You can force the direct access session to close by logging on as administrator and entering “Esc 1 * 0CD .”

Port redirect

Using the port redirector, the card allows data to be sent and received directly to and from the display and back to the client (e.g., a PC or the MLC 206) without any processing.

1.Open another Telnet session (see the previous section for details).

2.Reestablish a pass-through by using the “set redirect mode” command:

Esc 2*1*500*3DCD

Troubleshooting

Turn on the plasma display and the control devices (PC, laptop, etc.).

If the output Pioneer plasma cannot be remotely controlled, check the following:

Power connections

1.

Ensure that the Pioneer plasma is plugged in.

2.

If the Pioneer and the IPL M PDP-ES are receiving power,

 

its Power LED should be on.

Data connections

1.

Check the cabling connections and make adjustments as

 

needed. The Link LEDs on the IPL M PDP-ES and the

 

computer should be solid green if a network connection is

 

detected. If these LEDs are not lit, the cable is either faulty

or not plugged in; or the wrong type of cable is being used (refer to Connecting the Hardware, in chapter 3).

2.Try to ping the unit by entering ping 192.168.254.254 at the DOS command prompt; or use the Web address provided to you by your system administrator. If you get no response:

a.Make sure your unit is using the appropriate subnet mask and/or gateway IP address (check with your system administrator).

b.Make sure your PC does not have a software firewall program that might block the IP address of the unit.

4-30 IPL M PDP-ES • Communication and Control

IPL M PDP-ES • Communication and Control 4-31

Image 30
Contents User’s Manual IP Link ToolsPrecautions Extron’s WarrantyFCC Class a Notice Quick Start Guide IPL M PDP-ES Attach the network LAN cable to the LAN portTable of Contents Table of Contents, cont’d IntroductionAbout this Manual FeaturesIntroduction About the IPL M PDP-ES Interface CardInstallation and Operation Introduction, cont’dInstallation of the IPL M PDP-ES Interface Card Installation and OperationInstallation Overview Installing the Extron IPL M PDP-ES cardPower Installation and Operation, cont’dPanel Features and Cabling Ethernet/LAN communicationResetting the unit OperationRS-232 communication Connection and Configuration ThreeConnection and Configuration Connecting the Hardware Configuring the HardwareConfiguring the IPL M PDP-ES using the ARP command Connection and Configuration, cont’dIPL M PDP-ES interface card configuration Arp -s 10.13.170.15 00-05-A6-00-0A-90192.168.254.253 Configuring the IPL M PDP-ES using direct PC connectionConfiguring the IPL M PDP-ES using the RS-232 port Esc 10.13.170.15 CIFirmware upgrades Communication and ControlCommunication and Control Accessing and using the Web serverNavigating the default Web pages Communication with the Interface CardIP settings fields Port SettingsPasswords Communication and Control, cont’dEmail Alerts Firmware upgrade Sending an email alert through TelnetEsc 4 SM To create a directory To add or update filesFile Management tab To delete unwanted files or directoriesDisplay Status PowerPioneer tab Display ControlsAdvanced Controls Energy Save ScheduleMonitor Using the command/response table Symbol definitionsPassword information Error responsesCopyright information PortData Bidirectional SerialFirmware Version/Part Number/Information IP Setup Commands Password and Security SettingsFile Commands Directories Re-map port designationsWeb Browser Specific Custom Web pages Telnet portTroubleshooting Direct access portSpecifications, Part Numbers, and Accessories Serial connectionsIf status is missing or unavailable, check the following Specifications PartsSpecifications, Part Numbers, Accessories, cont’d GlossaryGlossary GlossaryGlossary, cont’d Glossary, cont’d

68-1021-01 specifications

Extron's electronic 68-1021-01 is a versatile and advanced presentation switcher that caters to the growing demands of modern multimedia environments. This device is designed to simplify the process of connecting various audio and video sources to a single output, making it ideal for classrooms, boardrooms, and other professional settings where seamless presentations are essential.

One of the main features of the 68-1021-01 is its ability to handle multiple video formats. It supports HDMI, Composite Video, and RGB inputs, allowing users to connect a diverse range of devices, from laptops and document cameras to legacy equipment. This multi-format capability ensures that users can integrate their existing technology without the need for extensive upgrades.

The switcher's advanced signal processing technology contributes to optimal video quality. It features built-in scaling capabilities, which adjust the resolution of incoming signals to match the output requirements. This ensures that the image quality remains sharp and crisp, regardless of the source, minimizing potential degradation that can occur during format conversions.

Another notable aspect of the Extron 68-1021-01 is its user-friendly interface. It provides an intuitive control mechanism that can be customized to fit the operational preferences of the user. The device can be managed via button inputs, remote controls, or even through third-party control systems, offering flexibility in how users interact with the system.

In addition to video capabilities, the 68-1021-01 is equipped with robust audio management features. It integrates audio switching and processing, which allows users to manage audio signals from various sources seamlessly. This is particularly beneficial in environments where audio clarity is crucial, such as in presentations or video conferences.

The 68-1021-01 utilizes Extron's renowned EDID (Extended Display Identification Data) technology, which helps ensure compatibility between the source and display devices. This feature automatically communicates the display's capabilities, optimizing the connection to reduce the risk of resolution or formatting issues.

Finally, the build quality reflects Extron's commitment to durability and reliability. The device is designed for easy installation, with options for rack mounting or desktop use, and features robust connections to withstand everyday use in busy environments.

Overall, the Extron electronic 68-1021-01 stands out as an efficient and reliable presentation switcher that combines advanced technology with user-friendly design, making it a valuable addition to any modern audiovisual setup.